국내정수장의 잔류염소농도에 대한 조사연구 (Statistical Analysis of Chlorine Residual in Korean Drinking Water)

  • 손진식;강효순
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.281-287
    • /
    • 2006
  • Maintaining adequate chlorine residual is crucial in water treatment facilities, Treatment technique, newly promulgated regulation, requires sufficient disinfection in order to control more resistant microorganisms such as Viruses and Giardia lamblia. Each water treatment plant should report various water qualities including chlorine residual and disinfection by-products, thus plenty of data has been generated. Even though statistical analysis using these data are forced to investigate the status and effect of water qualities in water facilities very few researches have been performed in korea. This study performed statistical analysis of chlorine residual during three years in Korean drinking water. The average chlorine residual concentrations were 0.701mg/L, 0.738mg/L, 0.763mg/L in 2002, 2003, 2004, respectively. Monthly variations of chlorine residual was not significant. ANOVA result showed that yearly variance of chlorine residual is different in only less than $5000m^3/day$ of water treatment capacity. The statistical analysis can help government to establish new regulation with scientific basis.

고농도 차아염소산나트륨 발생장치의 소독부산물 제어에 관한 연구 (A Study on Control Disinfection By-products in High Sodium Hypochlorite Generation)

  • 조해진;신현수;고성호
    • 대한기계학회논문집B
    • /
    • 제41권3호
    • /
    • pp.183-189
    • /
    • 2017
  • 상수도 소독공정에서 사용되고 있는 차아염소산나트륨은 일반적으로 유효염소 0.8 %로 생산되어 투입되고 있으며, 투입량이 많아질수록 소독부산물(Chlorate)이 증가되었고 수질기준을 초과하게 된다. 이에 따라 본 연구에서는 유효염소를 12%로 높인 차아염소산나트륨 발생장치의 전해조에 대해 소독부산물을 제어할 수 있도록 양극수 pH를 조절하였다. 실험결과 전해조 내 양극수 pH를 4.2(일반적인 차아염발생장치 운전 pH)에서 1.53으로 조절함으로서 Chlorate 농도는 95% 이상 낮아진 것으로 나타났으며, 또한 낮은 전류가 인가됨에 따라 양극의 효율도 15% 개선되는 결과를 얻었다. 이 장치의 개발로 대용량 상수도에서도 안전한 차아염소산나트륨의 적용이 가능하여 소독공정의 안전성 향상에 기여할 것으로 기대된다.

감염된 미성숙 영구치에서 platelet-rich fibrin과 double antibiotic paste를 이용한 치수 재혈관화 : 증례 보고 (Pulp Revascularization of Infected Immature Permanent Teeth Using Platelet-Rich Fibrin and Double Antibiotic Paste : Case Report)

  • 전상윤;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제40권3호
    • /
    • pp.216-222
    • /
    • 2013
  • 감염된 미성숙 영구치의 치수치료에 있어 줄기세포의 분화를 유도하는 생활조직의 재생과 지속적인 치근형성을 도모하는 방향으로 패러다임이 전환되고 있는데, 여기에서는 소독, 스캐폴드(scaffold), 그리고 폐쇄가 중요하다. 소독을 위해 triple antibiotics가 널리 사용되고 있으며, 스캐폴드로써 기존의 혈병대신 platelet-rich fibrin의 사용이 보고되었다. 본 증례보고에서는 치외치 파절에 의해 치수가 감염된 미성숙 영구치에서 platelet-rich fibrin을 스캐폴드로써 이용한 치수 재혈관화를 시행하였다. 발수와 근관세척 후 첫 증례에서 국소적 항생제의 적용 없이 platelet-rich fibrin을 단독 사용하였고 두 번째와 세 번째 증례에서는 국소적 항생제 적용 후 platelet-rich fibrin을 적용하였는데 모두 양호한 치유 결과를 얻었다.

THMs, HAAs의 종분포 (Speciation of THMs, HAAs)

  • 김진근
    • 대한환경공학회지
    • /
    • 제28권11호
    • /
    • pp.1135-1140
    • /
    • 2006
  • 국내 정수장에서 염소소독시 발생하는 소독부산물인 트리할로메탄(THMs), 할로아세틱에시드(HAAs)의 발생농도와 각각의 종별 분포현황을 조사하였다. 조사대상은 일반적인 정수처리공정으로 구성된 한강, 금강, 섬진강, 낙동강 수계의 1개 정수장씩 총 4개소였다. THMs의 발생농도는 평균 26.9 ppb, 최대 46.7 ppb, 최소 11.0 ppb였으며, $HAA_5$의 발생농도는 평균 25.4 ppb, 최대 57.1 ppb, 최소 9.7 ppb였다. 계절적으로는 동절기에 농도가 낮았고 하절기에 높았다. THMs의 종별 분포를 조사한 결과 클로로포름의 비율이 평균 77%로 가장 높았고 다음으로는 브로모디클로로메탄(20%)이 높게 검출되었으며, 브로모포름의 농도는 정량한계 미만이었다. $HAA_5$의 경우 디클로로아세틱에시드(DCAA)와 트리클로로아세틱에시드(TCAA)의 합이 $HAA_5$의 97%를 차지하는 것으로 조사되었다. 그러나 한강수계의 경우는 이 비율이 평균 90%로 다소 낮았으며, 특히 겨울철에 비율이 가장 낮았다. 한편, 하절기를 제외하고는 DCAA가 TCAA보다 높은 것으로 조사되었다.

벼 키다리병 방제에 관한 황토유황의 종자소독 효과 (Effect of Rice Seed Disinfection of Loess-sulfur on the Suppression of Bakanae disease caused by Fusarium fujikuroi)

  • 소현규;김용기;홍성준;한은정;박종호;심창기;김민정;김석철
    • 한국유기농업학회지
    • /
    • 제25권2호
    • /
    • pp.345-355
    • /
    • 2017
  • 본 연구는 황토유황을 활용하여 벼 키다리병 발병을 최소화할 수 있는 최적 종자소독조건을 선발하기 위해 수행되었다. 키다리병에 이병된 '신동진' 품종 벼 종자를 공시하였고 황토유황 농도, 침지온도, 시간, 온탕여부를 구분하여 실내 및 온실검정을 통해 침지시간은 48시간, 침지농도는 1%로 최적 소독조건을 선발하였다. 그리고 모판과 포장시험을 수행하여 온탕처리 후 $20^{\circ}C$, 1% 황토유황에 48시간 침지 처리구와 $30^{\circ}C$, 1% 황토유황에 48시간 단독 침지할 때 가장 효과가 높았다는 것을 확인하였고 위 처리조건으로 소독한 종자가 육묘, 이앙, 출수기를 거치면서도 100%의 높은 방제효과가 유지되는 것을 확인할 수 있었다. 그러나 $20^{\circ}C$에서 1% 황토유황으로 침지한 처리구에서는 포장에서 78.2%의 낮은 방제가를 보였다. 또한, 온탕소독만 수행한 처리구에서도 $60^{\circ}C$, 10분간 충실히 수행될 경우 효과적인 벼 키다리병 방제가 가능함을 보여주었지만 온탕처리 후 황토유황으로 추가 침지함으로서 많은 양의 종자를 소독할 때 좀 더 나은 키다리병 방제 효과를 가져다 줄 수 있을 것으로 판단된다. 이상의 결과를 종합하여 볼 때 농가에서 온탕소독기와 종자소독기 둘 중 한가지만 구비하더라도 황토유황을 이용하여 충분한 소독효과를 낼 수 있기 때문에 현장에서 보다 쉽게 활용될 수 있을 것으로 판단되며 제조방법이 쉽고 비용이 적게 드는 황토유황의 특성상 농가의 경영비 절감효과도 클 것으로 기대된다.

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

선박 평형수 처리용 대전류 인버터 방식의 정류기 설계 (Design of High-Current Inverter-type Rectifier for Electrolytic Disinfection of Ship Ballast Water)

  • 조원우;김진영;김인동;노의철;고강우;배상범
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.430-439
    • /
    • 2011
  • 세계화와 더불어 수출 입 물동량이 크게 늘어남에 따라 세계를 왕래하는 선박의 평형수(Ballast water) 속에 존재하는 해양 유기체에 의한 생태계의 파괴가 큰 문제가 되고 있다. 이와 같은 문제를 해결하기 위해 국제규약은 선박의 평형수를 배출할 때는 반드시 미생물을 제거한 다음 바다로 배출할 것을 요구하고 있다. 이는 위한 염소발생용 전기분해 수 처리 시스템을 위해 우수한 성능을 가지는 저전압 대전류 방식의 정류기의 필요성이 커지고 있다. 본 논문에서는 선박의 평형수 처리를 위한 해수 전기분해용 정류기에 적합한 저전압 대전류 정류기 방식을 제안하고, 정류기 전력회로 설계와 제어기 설계에 필요한 실제적인 설계 가이드라인을 제시하고자 한다.

Disinfection of Escherichia coli and Bacillus subtilis using underwater plasma

  • 유승민;노태협;석동찬;유승렬;홍용철;이봉주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.47-47
    • /
    • 2010
  • Discharge under the water is very hard and demand considerable high voltage. But specially improved electrode can generate plasma discharge to salty water with relatively low voltage. A round shape ceramic electrode having many pinholes combined with metallic one can generate plasma. 400 volt, 10 kHz and 3 micro second pulse width were applied to repeatedly running synthetic seawater with 10 L/m velocity, containing cultivated E. coli and Bacillus. As a result, 18, 94, 99.97, 100, 100 % disinfection rates to E. coli and 17.1, 17.1, 82.9, 99.4, 99.9 % disinfection rates to Bacillus subtilis were achieved to 1, 2, 3, 4, 5 times repetitive treatment respectively. In the plasma condition, the ions and electrons are separated and new kinds of components are re-synthesized by the intensive movement of the components. Especially chlorine ions are separated and recombined to residual free chlorine like HOCl, $OCl^-$. The residual free chlorine concentrations of discharged water were 0.25, 0.88, 1.39, 1.59, 1.66 mg $Cl_2$/L after 5 times treatment respectively. Another unconfirmed radical and oxidants for example, OH, $H_2O_2$, and $O_3$ can have an effect on microorganism of course.

  • PDF