• Title/Summary/Keyword: Disinfection treatment

Search Result 372, Processing Time 0.027 seconds

Hyaluronic Acid Subdermal Filler for Correction of Lower Eyelid Entropion in a Cat

  • Kim, Youngsam;Kang, Seonmi;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.37 no.5
    • /
    • pp.292-294
    • /
    • 2020
  • A 14-year-old castrated male Persian cat presented with epiphora, blepharospasm, brownish ocular discharge, corneal neovascularization, and corneal opacity in the left eye. Medial lower eyelid entropion was diagnosed through an ophthalmic examination. Since the cat was old and suffered from chronic kidney disease, we decided to perform a hyaluronic acid (HA) subdermal filler injection without general anesthesia rather than surgical correction. After topical anesthesia by lidocaine jelly and disinfection, HA filler was injected into the medial lower eyelid under minimal physical restraint. At the last follow-up 139 days later, lower eyelid entropion was not observed and related clinical signs disappeared. Therefore, HA subdermal filler can be an effective intervention for the treatment of entropion in cats.

Study on Methodology for Reducing Dead Zone Flow within Chlorine Contactor Installing Porous Baffles (유공벽을 이용한 우류식 염소접촉조 사류 저감 방안 연구)

  • Park, Hyun-Ho;Park, No-Suk;Cha, Min-Whan;Kim, Sa-Dong;Won, Chan-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.519-525
    • /
    • 2010
  • From the results of tracer test for the existing chlorine contactor in Y water treatment plant, $T_{10}$ and $T_{10}$/T were calculated as 130 min and 0.16, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by T10 and $T_{10}$/T, and disinfection performance. In this study, in order to reduce dead zone within contactor, the installation of porous baffles in the near of each corner was suggested and verified using transient CFD(Computational Fluid Dynamics) simulation technique and tracer tests on dynamic condition. From the results of simulation and tracer tests, it was revealed that porous baffles installed have been effective to reduce dead zone within contactor, and increase plug flow fraction.

A Study on the Microbubble Characteristics of Ozone to Improve Dissolution Efficiency (오존 용해효율 향상을 위한 미세기포 특성 연구)

  • Kim, Jin-Hoon;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.6
    • /
    • pp.47-53
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.

A Novel Pulse Density Modulated High Frequency Inverter for Streamer Reactor (스트리머 발생을 위한 새로운 PDM 고주파 인버터)

  • Kim, J.Y.;Mun, S.P.;Suh, K.Y.;Lee, H.W.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.223-225
    • /
    • 2005
  • This paper presents a novel prototype of a current source resonant inverter using insulated gate bipolar transistors for driving a streamer reactor, streamer generation technology has been recognized as one of the best methods for water treatment, disinfection, industrial wastes utilization, and so on. However, some technological difficulties related to efficient streamer production have been significant problems restricting streamer usage in the industrial plants. Introduced in this paper is a pulse density modulated high frequency inverter for a plasma generate, which is developed with the aim to improve power conversion and control characteristics of the streamer reactor by using advances in power electronic technology. The developed system implements the feedforward control-based pulse density modulation control scheme with pulse width modulation feedback control strategy to compensate temperature and other environmental influences on streamer discharge.

  • PDF

Triboelectric Energy Harvesting for Self-powered Antibacterial Applications

  • In-Yong Suh;Sang-Woo Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.213-218
    • /
    • 2023
  • Triboelectric nanogenerators (TENGs) have emerged as a highly promising energy harvesting technology capable of harnessing mechanical energy from various environmental vibrations. Their versatility in material selection and efficient conversion of mechanical energy into electric energy make them particularly attractive. TENGs can serve as a valuable technology for self-powered sensor operation in preparation for the IoT era. Additionally, they demonstrate potential for diverse applications, including energy sources for implanted medical devices (IMDs), neural therapy, and wound healing. In this review, we summarize the potential use of this universally applicable triboelectric energy harvesting technology in the disinfection and blocking of pathogens. By integrating triboelectric energy harvesting technology into human clothing, masks, and other accessories, we propose the possibility of blocking pathogens, along with technologies for removing airborne or waterborne infectious agents. Through this, we suggest that triboelectric energy harvesting technology could be an efficient alternative to existing pathogen removal technologies in the future.

Chemistry of persulfates for the oxidation of organic contaminants in water

  • Lee, Changha;Kim, Hak-Hyeon;Park, Noh-Back
    • Membrane and Water Treatment
    • /
    • v.9 no.6
    • /
    • pp.405-419
    • /
    • 2018
  • Persulfates (i.e., peroxymonosulfate and peroxydisulfate) are capable of oxidizing a wide range of organic compounds via direct reactions, as well as by indirect reactions by the radical intermediates. In aqueous solution, persulfates undergo self-decomposition, which is accelerated by thermal, photochemical and metal-catalyzed methods, which usually involve the generation of various radical species. The chemistry of persulfates has been studied since the early twentieth century. However, its environmental application has recently gained attention, as persulfates show promise in in situ chemical oxidation (ISCO) for soil and groundwater remediation. Persulfates are known to have both reactivity and persistence in the subsurface, which can provide advantages over other oxidants inclined toward either of the two properties. Besides the ISCO applications, recent studies have shown that the persulfate oxidation also has the potential for wastewater treatment and disinfection. This article reviews the chemistry regarding the hydrolysis, photolysis and catalysis of persulfates and the reactions of persulfates with organic compounds in aqueous solution. This article is intended to provide insight into interpreting the behaviors of the contaminant oxidation by persulfates, as well as developing new persulfate-based oxidation technologies.

The Evaluation of Performance Limiting Factors for the Optimization of Drinking Water Treatment (정수장 최적화를 위한 성능제한인자 평가에 관한 연구)

  • Kim, Jeong Hyun;Bae, Chul Ho;Park, No Suk;Moon, Yong Taik;Lee, Sun Ju;Kown, Soon Buhm;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.78-91
    • /
    • 2005
  • Performance limiting factors (PLFs) derived from 161 drinking water treatment plants (DWTPs), assessed by International Technical Diagnosis & Assistance Center, were analyzed and evaluated in more detail in this study. In order to conduct study, 161 DWTPs were divided into five categories depending on their capacity, and into twelve groups according to processes and facilities. From the results of analysis, PLFs and their distribution ratio derived from each category were significantly different. Filtration was the most important performance limiting process in all DWTPs of five categories, and the PLFs in filtration were backwashing velocity, media configuration, bed depth, and formation of mud-ball. The PLFs in coagulation-flocculation process were found out to be coagulant dosage, mixing speed, mechanical problems, and others in the order of frequency of occurrence. Also, insufficient disinfection ability that is resulted from insufficient hydraulic detention time and improper chlorine dose and injection point, is the most significant among PLFs in a clear well. In the case of sedimentation, inappropriate baffle structure and excessive upward velocity were PLFs. In addition, the results showed that high turbid water and low alkalinity in a rainy season, ferric and manganese ions, and ammonia nitrogen have been contributed significantly on the performance of DWTPs.

Study of Recognition about Hospital Infection Management in Physical Therapists (물리치료사의 병원 감염관리에 대한 인지도 연구)

  • Song, Min-Young;Lee, Tae-Sik
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.3
    • /
    • pp.141-150
    • /
    • 2002
  • Most of physical therapists has thought be exposed themselves to risk of hospital infection but it is reported that have been low concern about infection management. Above like this haven t done systematical education on hospital infection, also physical therapist's information management of infection disease is found very low. It is lack of driving information about disease condition of the patients. Physical therapists has thought their working room may be polluted a lots of micro-organism(%). The control situation of infection waste articles, only 53% responded that the controller has managed very intensive so we can feel to need more intensive It's reported that air culture investigation of physical therapy room has never initiated. To wash the hand, before, after treatment of the patients of physical therapist, is very low frequency. And 73% have responded that the time to wash the hand stays 15-45 second. It is examined that 70% physical therapy room is equipped with washing system, a response of 58% disinfects physical therapy room 1-2times per one month. 36% responded disinfection of treatment modality have done everyday, 25% responded have never done. The location physical therapy room is above one floor - 65%. A response of 57% is ventilation system sufficiency, it is considered that physical therapists needs more efforts on management of hospital infection.

  • PDF

Germicidal Effect of Electrolyzed Seawater on Live Fish and Shellfish (전기분해 해수의 활어패류 살균 효과)

  • Lee, Hee-Jung;Yu, Hongsik;Oh, Eun-Gyoung;Shin, Soon Bum;Park, Kunbawui;Kim, Ji Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.5
    • /
    • pp.534-539
    • /
    • 2013
  • To secure the biological safety of live fish and shellfish for raw consumption, the germicidal effects of electrolyzed seawater were evaluated. Upon direct exposure to electrolyzed seawater, coliform group bacteria were killed and decreased to undetectable levels after 1 day. The physicochemical characteristics of the seawater were stable during the test period. A byproduct of chlorine disinfection, trihalomethane, was not generated by the electrolysis of seawater. Vibrio parahaemolyticus infection in a live fish was effectively resolved by electrolyzed seawater and became undetectable after 12-36 h of treatment. Bioaccumulation of coliform group and fecal coliform bacteria in live oysters Crassostrea gigas was removed within 18 h of treatment. This study demonstrated that electrolyzed seawater is an effective and safe germicidal agent for the traditional retail market and can help to prevent outbreaks of foodborne disease associated with the consumption of raw fish and shellfish.

Treatment of White Line Disease by Therapeutic Shoeing in Horse (장제요법에 의한 말의 백선병 치료 1례)

  • Yang, Young-Jin;Shin, Sang-Kyung;Yun, Sung-Wook;Cho, Gil-Jae
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.394-398
    • /
    • 2013
  • An 3-year-old female Thoroughbred horse was referred with moderate lameness (3/5G) and mild heat on right hoof of forelimb. She was diagnosed with white line disease (WLD) that was included hoof wall separation by radiographic examination and hoof percussion. Treatment was carried out hoof wall resection at first, followed by disinfection of affected hoof and shod modified heart bar. On the re-examination after 4 months, we could find a results which had no lameness, gas pocket in the white line and clinical signs was improved. Subsequently, she was trained and raced after 8 months of diagnosis. So, we supposed that resection of wall and therapeutic shoeing was good for WLD including hoof separation.