• Title/Summary/Keyword: Disinfecting Agent

Search Result 6, Processing Time 0.025 seconds

Morphological aspect of the attached bacteria by the sterilization method of the ultrasonic scaling tip (소독멸균 방법에 따른 초음파 스케일링 팁에 부착된 세균의 양상)

  • Nam, Seoul-Hee;Kim, Yu-rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.4
    • /
    • pp.713-718
    • /
    • 2015
  • Objectives: The purpose of the study was to investigate the bacterial morphology attached on ultrasonic scaler tips using no cleansing solution, alcohol cotton, liquid chemical disinfecting agent, and autoclave method. Methods: Scaling tip was applied to the mouth and the ultrasonic scaler tips were assigned to four groups. Group 1 was control group with no cleansing solution. Group 2 was treated with alcohol cotton. Group 3 was treated with 2% green Y-Na solution in liquid chemical disinfecting agent, and Group 4 was sterilized by autoclave method. Live bacteria were observed by phase contrast microscopy. The scanning electron microscopy(SEM) revealed the morphological characteristics of scaler surface. The type of attached bacteria were analyzed using SPSS 21.0 program. The data were analyzed by one-way analysis of variance(ANOVA) and Tukey's post-hoc test. Results: The types of sterilization methods had influences on the bacterial viability. The numbers of cocci, bacilli, spiral form bacteria, and filamentous bacteria was observed in $89.00{\pm}3.60%$, $29.67{\pm}3.51%$, $3.33{\pm}0.57%$ and $1.67{\pm}0.57%$ in control group, $31.67{\pm}3.51%$, $63.33{\pm}4.04%$, $2.00{\pm}1.00%$ and $1.67{\pm}0.57%$ in alcohol cotton group, $69.67{\pm}4.50%$, $12.33{\pm}2.51%$, 0% and 0% in liquid chemical disinfecting agent group, and 0.0%, 0.0%, 0.0% and 0.0% in autoclave method group. The clean surface of ultrasonic scaler tip was shown on SEM by autoclave method. Conclusions: The most effective sterilization method of ultrasonic scaler tip was the autoclave method. Autoclave method is the most effective sterilization method and can reduce the cross-infection in the dental clinic.

Effect of 2, 6-Dichlorobenzonitrile on Amoebicidal Activity of Multipurpose Contact Lens Disinfecting Solutions

  • Moon, Eun-Kyung;Lee, Seungeun;Quan, Fu-Shi;Kong, Hyun-Hee
    • Parasites, Hosts and Diseases
    • /
    • v.56 no.5
    • /
    • pp.491-494
    • /
    • 2018
  • Multipurpose contact lens disinfecting solutions (MPDS) are widely used to cleanse and disinfect microorganisms. However, disinfection efficacy of these MPDS against Acanthamoeba cyst remain insufficient. 2, 6-dichlorobenzonitrile (DCB), a cellulose synthesis inhibitor, is capable of increasing the amoebical effect against Acanthamoeba by inhibiting its encystation. In this study, we investigated the possibility of DCB as a disinfecting agent to improve the amoebicidal activity of MPDS against Acanthamoeba cyst. Eight commercial MPDS (from a to h) were assessed, all of which displayed insufficient amoebicidal activity against the mature cysts. Solution e, f, and h showed strong amoebicidal effect on the immature cysts. Amoebicidal efficacy against mature cysts remained inadequate even when the 8 MPDS were combined with $100{\mu}M$ DCB. However, 4 kinds of MPDS (solution d, e, f, and h) including $100{\mu}M$ DCB demonstrated strong amoebicidal activity against the immature cysts. The amoebicidal activity of solution d was increased by addition of DCB. Cytotoxicity was absent in human corneal epithelial cells treated with either DCB or mixture of DCB with MPDS. These results suggested that DCB can enhance the amoebicical activity of MPDS against Acanthamoeba immature cyst in vitro.

Effects of Residual Hypochlorite Ion on Methane Production during the Initial Anaerobic Digestion Stage of Pig Slurry

  • Yoon, Young-Man;Kim, Hyun-Cheol;So, Kyu-Ho;Kim, Chang-Hyun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.1
    • /
    • pp.122-127
    • /
    • 2013
  • The hypochlorite ion ($OCl^-$) is a widely used disinfecting agent in pig rearing in Korea, but its residual effect on $CH_4$ production from pig slurry is unclear. The objective of this study was to investigate the inhibition effects of residual $OCl^-$ on $CH_4$ production during the initial anaerobic digestion stage of pig slurry. Three organic concentrations (9.9, 26.2 and 43.7 g/L) of volatile solids (VS) were tested with the addition of 52.3 mg/L $OCl^-$, ten times of the typical concentration used in Korea, or without $OCl^-$ (Control) in anaerobic batch culture. The culture was run under mesophilic ($38^{\circ}C$) conditions for 20 d. At the lowest organic concentration with $OCl^-$, the VS degradation was 10.3% lower (p<0.05) than Control, while at the higher organic concentration with $OCl^-$, it did not differ from Control. $CH_4$ yields were higher in the control treatments than their $OCl^-$ counterpart cultures, and $CH_4$ yields of Control and $OCl^-$ treatments at the organic concentrations of 9.9, 26.2 and 43.7 g/L differed in the probability level (p) of 0.31, 0.04, and 0.06, respectively. Additionally, $CH_4$ concentration increased steeply and reached 70.0% within 4 d in the absence $OCl^-$, but a gradual increase up to 60.0% was observed in 6 d in the $OCl^-$ treated cultures. The $R_m$ (the maximum specific $CH_4$ production rate) and ${\lambda}$ (lag phase time) of 9.9 g/L with $OCl^-$ were 8.1 ml/d and 25.6 d, while the $R_m$ was increased to 15.1 ml/d, and ${\lambda}$ was reduced to 11.4 d in PS-III (higher organic concentration) with $OCl^-$. The results suggest that a prolonged fermentation time was necessary for the methanogens to overcome the initial $OCl^-$ inhibitory effect, and an anaerobic reactor operated with high organic loadings was more advantageous to mitigate the inhibitory effect of residual hypochlorite ion.

Effect of Treatment with Ozonated Water on Shelf Life of Refrigerated Meat (오존수 처리가 냉장 쇠고기의 화학적 품질에 미치는 영향)

  • Kim, Min-Ju;Shin, Han-Seung
    • Food Science of Animal Resources
    • /
    • v.31 no.4
    • /
    • pp.617-623
    • /
    • 2011
  • Ozone is a strong oxidant and potent disinfecting agent. In this study, volatile basic nitrogen, thiobarbituric acid reactive substances, acid value and pH all of which are quality indicators in meat products, were evaluated. The meat was treated with the ozonated water (0.2 ppm) for 0, 5, 10, 30, and 60 min and then stored at $5^{\circ}C$ for 24 d. The volatile basic nitrogen content of meat was 22.40 mg% after 9 d of storage and 23.24 mg% at 15 d of storage with ozonated water (0.2 ppm) treatment. During 24 d of storage, the pH, thiobarbituric acid reactive substances, and acid value were decreased when subjected to ozonated water treatment. These results suggested that the ozonated water treatment effectively improved the chemical properties and food safety.

In vitro evaluation of octenidine as an antimicrobial agent against Staphylococcus epidermidis in disinfecting the root canal system

  • Chum, Jia Da;Lim, Darryl Jun Zhi;Sheriff, Sultan Omer;Pulikkotil, Shaju Jacob;Suresh, Anand;Davamani, Fabian
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.1
    • /
    • pp.8.1-8.7
    • /
    • 2019
  • Objectives: Irrigants are imperative in endodontic therapy for the elimination of pathogens from the infected root canal. The present study compared the antimicrobial efficacy of octenidine dihydrochloride (OCT) with chlorhexidine (CHX) and sodium hypochlorite (NaOCl) against Staphylococcus epidermidis (S. epidermidis) for root canal disinfection. Materials and Methods: The minimum inhibitory concentration (MIC) was obtained using serial dilution method. The agar diffusion method was then used to determine the zones of inhibition for each irrigant. Lastly, forty 6-mm dentin blocks were prepared from human mandibular premolars and inoculated with S. epidermidis. Samples were randomly divided into 4 groups of 10 blocks and irrigated for 3 minutes with saline (control), 2% CHX, 3% NaOCl, or 0.1% OCT. Dentin samples were then collected immediately for microbial analysis, including an analysis of colony-forming units (CFUs). Results: The MICs of each tested irrigant were 0.05% for CHX, 0.25% for NaOCl, and 0.0125% for OCT. All tested irrigants showed concentration-dependent increase in zones of inhibition, and 3% NaOCl showed the largest zone of inhibition amongst all tested irrigants (p < 0.05). There were no significant differences among the CFU measurements of 2% CHX, 3% NaOCl, and 0.1% OCT showing complete elimination of S. epidermidis in all samples. Conclusions: This study showed that OCT was comparable to or even more effective than CHX and NaOCl, demonstrating antimicrobial activity at low concentrations against S. epidermidis.

Determination of the mole fractions of ethylene oxide and freons in medical liquefied gas mixture by GC/AED (GC/AED를 이용한 의료용 액화혼합가스 중 산화에틸렌 및 프레온 가스류의 몰분율 측정)

  • Kim, Hyunjoo;Kim, Dalho;Lim, Arang;Lee, Taeck-Hong;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.382-387
    • /
    • 2012
  • Ethylene oxide ($C_2H_4O$, EtO) is used as a raw material for the production of ethylene glycol and other industrially important material such as ethanolamines and also used as a disinfecting agent. It is applied for gas-phase sterilization of thermally sensitive medical equipment, and for processing of storage facilities as a mixture with fluorinated hydrocarbon. In this perspective, accurate determination of the mole fractions of components in the liquefied gas mixture is required for the quality control and safety of production and use. Each component of the liquefied gas mixture has different chemical and physical properties such as vapor pressure and boiling point. Therefore, we can suppose that analytical results can be different according to the introduction method for the gas phase of upper layer, or for the liquid phase of lower layer in gas cylinder. In this study, we designed a new on-line sample injection device for the liquefied gas mixture in liquid or gas state, and applied to the analysis of liquefied gas mixture of ethylene oxide and fluorinated hydrocarbons by GC/AED (gas chromatograph-atomic emission detector). We studied performance of AED, and effect of sample introduction and selected wavelength to the accuracy and repeatability of analytical results.