• Title/Summary/Keyword: Discrete fin

Search Result 9, Processing Time 0.026 seconds

Study on Heat Transfer Characteristics of Discrete Fin-and-tube Heat Exchangers (독립 핀-튜브 열교환기의 열전달 성능특성에 관한 연구)

  • Lee, Ho-Seong;Kim, Yong-Han;Choi, Jong-Min;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.274-280
    • /
    • 2005
  • The objective of this study Is to investigate the heat transfer performance of plate discrete fin-and-tube heat exchangers with large fin pitch. In this study, twenty-two heat exchangers were tested with a variation of fin pitch, number of tube row, longitudinal tube pitch and fin alignment. Discrete fin type exchangers improved heat transfer performance more than 10% compared to tile continuous fin type heat exchangers. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row, The staggered fin alignment improved heat transfer performance more than 6% compared to the inline fin alignment. The effect of longitudinal tube pitch was insignificant on the j-factor and experiments found opposite effects on the j-factor with respect to fin alignment. Heat transfer correlations were developed from the measured data for flat plate discrete fin-and-tube heat exchangers with large fin pitch. The correlations yielded good predictions of the measured data with mean deviations of 1,4% and 0.3% for tire inline and staggered tube alignment, respectively.

  • PDF

Heat Transfer Performance of Evaporator Used in a Domestic Refrigerator/Freezer Under Frosting Condition (착상을 고려한 가정용 냉동/냉장고 증발기의 열전달 성능)

  • Lee Jang-Seok;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-70
    • /
    • 2005
  • In this study, the air-side heat transfer coefficients of several types of evaporators in the household freezer/refrigerators are investigated. The types considered in this work are: discrete flat plate fin-and-tube type(in-lined tube array), continuous flat plate fin-and-tube type(staggered tube array), and spine fin-and-tube type(in-lined tube array). The heat transfer correlations obtained from this study for each heat exchangers could expect heat transfer coefficients less than $5\%$ of errors. The result indicates that the air-side heat transfer performance of spine fin-and-tube type evaporator shows the highest value under dry conditions, but discrete flat plate fin-and-tube type evaporator shows the highest value among these three evaporators under frosting conditions.

Frosting Heat Transfer Characteristics of Evaporators Used for Household Refrigerators According to Fin Configuration (냉장고용 증발기의 핀 형상 변화에 따른 착상 열전달 성능특성)

  • Lee, Moo-Yeon;Lee, Sang-Heon;Jung, Hae-Won;Kim, Yong-Chan;Park, Jae-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1071-1078
    • /
    • 2010
  • The objective of this study is to investigate the heat transfer characteristics of evaporators that have various fin configurations and are used in household refrigerators. The frosting and defrosting characteristics of a spirally coiled circular fin-tube evaporator, a discrete-plate fin-tube evaporator, and a continuous-plate fin-tube evaporator were measured and compared. Under non-frosting conditions, the heat transfer coefficient of the spirally coiled circular fin-tube evaporator was 22.3% and 40.2% higher than the coefficients of the discrete- and continuous-plate fin-tube evaporators, respectively. Under frosting conditions, the heat transfer coefficient of the spirally coiled circular fin-tube evaporator was 27.0% and 46.3% higher than the coefficients of the discrete- and continuous-plate fin-tube evaporators, respectively. In addition, the defrosting water amount of the spirally coiled circular fin-tube evaporator was 3.2% and 9.4% lower than the amounts in the case of the discrete- and continuous-plate fin-tube evaporators, respectively.

Experimental Study on the Air-Side Heat Transfer Characteristics of a Spirally-Coiled Circular Fin-Tube Heat Exchanger According to Geometric Parameters (형상변수에 따른 나선형 원형핀-튜브 열교환기의 공기측 열전달 특성에 관한 실험적 연구)

  • Kang, Tae-Hyung;Lee, Moo-Yeon;Kim, Yong-Chan;Yun, Sung-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.515-522
    • /
    • 2010
  • The objective of this study is to investigate the air-side heat transfer characteristics of a spirally-coiled circular fin-tube heat exchanger for various geometric parameters under non-frosting conditions. The heat transfer characteristics of the heat exchanger were analyzed with respect to heat exchanger geometries, and then, the characteristics were compared with those of rectangular-plate fin-tube heat exchangers with discrete fins. The heat transfer coefficient increased with a decrease in the number of tube rows and an increase in the fin pitch. The optimum length of the L-foot was 2.7 mm. In addition, the heat transfer rate increased with a decrease in the tube pitch and the tube thickness. The heat transfer coefficient of the spirally-coiled circular fin-tube heat exchanger was 24.3% higher than that of the rectangular-plate fin-tube heat exchanger.

Thermal Analysis of a Radial Heat Sink with Radiation and Natural Convection (복사 열전달을 고려한 자연대류 원형 히트싱크 열전달 해석)

  • Yu, Seung-Hwan;Jang, Dae-Seok;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.385-390
    • /
    • 2012
  • A radial heat sink, adopted to LED(light emitting diode) downlight, was optimized. Discrete transfer radiation model (DTRM) was used to calculate radiation heat transfer, and numerical model was verified with experimental results. The effects of number of fin, long fin length and middle fin length on overall thermal resistance and radiation heat transfer were analyzed. As the emissivity increased, thermal resistance decreased due to the increment of radiation heat transfer. The radial heat sink was optimized and optimum number of long fins is 19~28, optimum length of long fin is about half of radius of heat fink and optimum fin ratio is 0.4~0.7.

The Study of Performance Evaluation Coefficient of Fin-and-Tube Heat Exchangers with Frosting (착상을 수반한 핀-관 열교환기의 성능평가계수에 관한 연구)

  • 최봉준;황준현;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • For the study of performance evaluation on different shape heat exchangers that have the same energy consumption in a refrigerator, we make performance evaluation coefficient (PEC) which can distinguish performance of different shape heat exchangers. The results were reported in order to compare with for the dry frosting and wet frosting test as various definition of PECs. Results showed that PEC of dry frosting test is higher than that of wet frosting test because attached water droplet increases pressure drop of air-side then this decreases performance of heat exchanger.

Covariance analysis describing function technique for missile performance (CADET를 이용한 가로방향 힘의 Saturation에 대한 미사일의 성능해석)

  • 김진호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.456-459
    • /
    • 1993
  • CADET is used to analyze the performance of the missile. Miss distance is calculated for a given lateral fin force saturation level due to the aerodynamic characteristics, target acceleration, and glint and fading noises which is assumed as Gaussian noises. As .alpha.-.betha. filter is studied to attenuate the noises, the results are compared with those of without filter. For the easy simulation, the transfer function of a discrete .alpha.-.betha. filter is converted into the continuous model. Simulation results show that the results of CADET simulation is similar to those of Monte-Carlo simulation. Moreover CADET is the better in computing time demand.

  • PDF

An Analysis of the Decision Factors on Mokpo Port by Multinomial Logit Model

  • Seong, Yu-Chang;Youn, Myung-Ou
    • Journal of Navigation and Port Research
    • /
    • v.31 no.2
    • /
    • pp.133-139
    • /
    • 2007
  • Relative importance of maritime transport that takes charge of main current of freight in country' economy is very large. Especially, port and facility carry out important role which treats freight of import and export smoothly and improves international trade as turning point, to achieve key role on connection and association between sea and land. For such reason, enlargement of port facilities or development of port needs to grasp exactly the utilization of port, attributes and selective factors of shipper. On the other hand, the amounts of physical distribution on Mokpo port located in Korean west coast are increasing, with fast economic growth of East Asian including China. This study uses discrete choice model that is measuring to analyze attribute and characteristic of Mokpo port, and analyzes port selection by decision factors of shipper. This paper composed a questionnaire using the result of preceding research, to decide port selection factor among competitive ports. Through factor analysis on a basis of the questionnaire' result, five principal components were extracted. These are resorted out by Logit model, to grasp competitive elements of port. This research fin present direction which raises competitive power of ports in west coast of Korea, especially on alternative and concentration of middle-class port as Mokpo may be useful.

A Study on Electromagnetic-Spring Actuator for Low Cost Miniature Actuators (소형 및 저비용화를 위한 전자석-스프링 구동장치 연구)

  • Kim, Sewoong;Lee, Changseop;Choi, Hyunyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.392-400
    • /
    • 2019
  • This paper provides a fin actuation system of missile based on electromagnetic-spring mechanism to miniaturize the system and lower the cost. Compared with proportional electro-mechanical actuators, the output of Electromagnetic-Spring Actuators(EMSA) has two or three discrete states, but the mechanical configuration of EMSA is simple since it does not need power trains like gears. The simple mechanism of EMSA makes it easy to build small size, low cost, and relatively high torque actuators. However, fast response time is required to improve the dynamic performance and accuracy of missiles since bang-off-bang operation of EMSA affects the flight performance of missile. In this paper the development of EMSA including parameter optimization and mathematical modeling is described. The simulation results using Simulink and experimental test results of prototype EMSAs are presented.