• Title/Summary/Keyword: Discharging voltage

Search Result 288, Processing Time 0.027 seconds

Proposal of the Energy Recovery Circuit for Testing High-Voltage MLCC (고전압 MLCC 시험을 위한 에너지 회수 회로 제안)

  • Kong, So-Jeong;Kwon, Jae-Hyun;Hong, Dae-Young;Ha, Min-Woo;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2022
  • This paper proposes a test device designed for developing a high-voltage multilayer ceramic capacitor (MLCC). The proposed topology consists of an energy recovery circuit for charging/discharging capacitor, a flyback converter, and a boost converter for supplying power and a bias voltage application to the energy recovery circuit. The energy recovery circuit designed with a half-bridge converter has auxiliary switches operating before the main switches to prevent excessive current from flowing to the main switches. A prototype has been designed to verify the reliability of target capacitors following the voltage fluctuation with a frequency range below 65 kHz. To conduct high root mean square (RMS) current to the capacitor as a load, the MLCC test was conducted after the topology verification was completed through the film capacitor as a load. Through the agreement between the RMS current formula proposed in this paper and the MLCC test results, the possibility of its use was demonstrated for high-voltage MLCC development in the future.

A Novel Charger/Discharger for the Parallel Connected Battery Module System (병렬 연결 배터리 모듈 시스템을 위한 새로운 충.방전기)

  • 조윤제
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.636-640
    • /
    • 2000
  • A novel integrated battery charger/discharger converter for a standardized battery module is proposed. Instead of using separate charger and discharger converters. it integrates these two converters into a single converter in order to minimize the size. the integrated charger/discharger converter not only regulates the solar array output power including the peak power tracking capability but also controls the battery charging/discharging current depending on the solar array output power and the load power. In addition it offers a regulated bus voltage which simplifies the power distribution/conversion for the pay load.

  • PDF

Development of the wind generation output stabilization with Lithium-ion battery (리티움-이온 배터리를 이용한 풍력발전의 출력안정화 시스템 개발)

  • Oh, Seung-Jin;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.178-179
    • /
    • 2010
  • This paper presents a simulation model and analysis of grid-tied wind turbine generator with batteries using the PSCAD/EMTDC software. The modeled system is consist of two inverters and one bidirectional DC/DC converter. These inverter are to capture the maximum active power under varying wind conditions and to keep the DC-Link voltage magnitude at a specific level. And the bidirectional DC/DC converter makes battery charging or discharging depend on power gap between wind turbine output and local load. Aerodynamic models are applied for a wind turbine blade simulator.

  • PDF

Energy Recovery Circuit for the Plasma Display Panel Sustainer

  • Cho, B.H.;Kim, W.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.625-630
    • /
    • 2005
  • In this paper, several energy recovery circuits (ERC) for the plasma display panel (PDP) are reviewed and classified in a manner of operation characteristics. A typical ERC using the Regenerative Transformer (RT) is introduced and compared with conventional ones. RT-ERC can achieve zero-voltage-switching (ZVS) for main full-bridge switches and zero-current-switching (ZCS) for the resonant switches and diodes. The charging/discharging energy of panel capacitance is efficiently recovered with the RT and without a sub-circuit. The presented circuit is verified with simulation and experimental results.

  • PDF

A 30 W Copper Vapor Laser Using a Vacuum Tube Based Pulse Generator (진공관 전원방식 30 W급 구리증기레이저)

  • 진정태;차병헌;김철중;이흥호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.568-572
    • /
    • 2003
  • A longitudinal discharge heated copper vapor laser with internal diameter 28 mm and discharge length 1.3 m has been constructed and tested. At the discharging voltage 15.2 kV, pulse repetition rate 10 kHz, buffer gas pressure 40 mbar, and internal temperature of the laser plasma tube $1520^{\circ}C$, it delivers more than 30 W average laser outputs.

Thickness Dependence of Stress Currents in Silicon Oxide (실리콘 산화막에서 스트레스 전류의 두께 의존성)

  • 강창수;이형옥;이성배;서광일
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.102-105
    • /
    • 1997
  • The thickness dependence of stress voltage oxide currents has been measured in oxides with thicknesses between 10nm and 80nm. The oxide currents were shown to be composed of stress current and transient current. The stress current was caused by trap assited tunneling through the oxide. The transient current was caused by the tunneling charging and discharging of the trap in the interfaces. The stress current was used to estimate to the limitations on oxide thicknesses. The transient current was used to the data retention in memory devices.

  • PDF

Battery energy storage system for 10kW wind turbine output stabilization (배터리 에너지 저장장치를 이용한 10kW 풍력발전출력 안정화 시스템 개발)

  • Oh, Seung-Jin;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.36-37
    • /
    • 2010
  • This paper presents a simulation model and results of experiment about analysis of grid-tied wind turbine generator with batteries. The system consists of two inverters and a bidirectional DC/DC converter. These inverters are to capture the maximum active power under varying wind conditions and to keep the DC-link voltage magnitude at a specific level. And the bidirectional DC/DC converter makes battery charging or discharging depend on power gap between wind turbine output and local load.

  • PDF

The Sugge Voltage restraint of induction motor using low-loss snubber circuit (저손실 스너버 회로를 이용한 유도전동기의 서지전압 억제)

  • Cho, Man-Chul;Mun, Sang-Pil;Kim, Chil-Yong;Kim, Ju-Yong;Shu, Ki-Young;Kwon, Soon-Kurl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.473-477
    • /
    • 2007
  • The development of advanced Insulated Gate Bipolar Transistor(IGBT)has enabled high-frequency switching operation and has improved the performance of PWM inverters for motor drive. However, the high rate of dv/dt of IGBT has adverse effects on motor insulation stress. In many motor drive applications, the inverter and motor are separated and it requires long motor feds. The long cable contributes high frequency ringing at the motor terminal and it results in hight surge voltage which stresses the motor insulation. The inverter output filter and RDC snubber are conventional method which can reduce the surge voltage. In this paper, we propose the new low loss snubber to reduce the motor terminal surge voltage. The snubber consists of the series connection of charging/discharging capacitor and the voltage-clamped capacitor. At IGBT turn-off, the snubber starts to operate when the IGBT voltage reaches the voltage-clamped level. Since dv/dt is decreased by snubber operating, the peak level of the surge voltage can be reduced. Also the snubber operates at the IGBT voltage above the voltage-clamped level, the snubber loss is largely reduced comparing with RDC snubber. The proposed snubber enables to reduce the motor terminal surge voltage with low loss.

  • PDF

A study on the design of triggering pulse generator for the triggered vacuum switch (진공스위치 트리거 발생기 설계에 관한연구)

  • Kim, Mu-Sang;Son, Yun-Gyu;Park, Ung-Hwa;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.201.2-201.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) is widely used as a high power switch in the field of pulsed power application. TVS can produce current of higher than 100 kA within a microsecond after being triggered. A triggering high voltage pulse generator supplies a high voltage signal to the trigger system to initiate the discharge between a trigger pin and one of main electrode. The trigger system, which consists of a tungsten trigger electrode and cylindrical ceramic insulator around it, is normally installed at the center of main cathode electrode. The discharging characteristics of the trigger system strongly depend on the geometry, electrode material, vacuum pressure and so on. In addition, we especially will focus on the developing a triggering pulse generator, which can vary not only value of voltage but also pulse duration, because its properties gives pivot influences on the TVS discharge. To verify such effects, we made a 3.3 kJ TVS set-up initially. Thus we will discuss some of prominent results from 3.3 kJ TVS system. In parallel we will show on the design of 300 kJ TVS system for the high current in the future.

  • PDF

A Study on Asymmetric Pulsed DC Plasma Power Supply with Energy Recovery Circuit (에너지 반환회로를 갖는 비대칭 펄스형 DC 플라즈마 전원장치에 관한 연구)

  • Choo, Dae-Hyeok;Yoo, Sung-Hwan;Kim, Joohn-Sheok;Han, Ki-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.593-600
    • /
    • 2013
  • The asymmetric pulsed DC reactive magnetron sputtering system is widely used for the high quality plasma sputtering process such as a thin film deposition. In asymmetric pulsed DC power supply a reverse voltage is applied to the target periodically to minimize arc discharging effect. When sputtering in the mid-frequency range (20-350 kHz), the periodic target voltage reversals suppress arc formation at the target and provide long-term process stability. Thus, high quality, defect-free coatings of these materials can now be deposited at competitive rates. In this paper, a new style asymmetric pulsed DC power supply including mid-transformer is presented. In the proposed, an energy recovery circuit is adopted to reduce the mutual inductance of the transformer. As a result, the system dynamics of the voltage control loop is increased highly and the non-linear voltage boosting effect of the conventional system is removed. This work was proved through simulation and laboratory based experimental study.