• 제목/요약/키워드: Discharge.charge-time

검색결과 242건 처리시간 0.026초

A Low-Power Single Chip Li-Ion Battery Protection IC

  • Lee, Seunghyeong;Jeong, Yongjae;Song, Yungwi;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권4호
    • /
    • pp.445-453
    • /
    • 2015
  • A fully integrated cost-effective and low-power single chip Lithium-Ion (Li-Ion) battery protection IC (BPIC) for portable devices is presented. The control unit of the battery protection system and the MOSFET switches are integrated in a single package to protect the battery from over-charge, over-discharge, and over-current. The proposed BPIC enters into low-power standby mode when the battery becomes over-discharged. A new auto release function (ARF) is adopted to release the BPIC from standby mode and safely return it to normal operation mode. A new delay shorten mode (DSM) is also proposed to reduce the test time without increasing pin counts. The BPIC implemented in a $0.18-{\mu}m$ CMOS process occupies an area of $750{\mu}m{\times}610{\mu}m$. With DSM enabled, the measured test time is dramatically reduced from 56.82 s to 0.15 s. The BPIC chip consumes $3{\mu}A$ under normal operating conditions and $0.45{\mu}A$ under standby mode.

Micro SMES를 이용한 전원공급 안정화장치 시뮬레이션을 위한 PSCAD/EMTDC 컴포넌트 모델링 (Component Modeling of Micro SMES Based Design of Stabilizer Simulation for Power Supply using PSCAD/EMTDC)

  • 김봉태;박민원;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.228-230
    • /
    • 2002
  • Recently, electric power reliability of our country has been improved. However, there are still remaining problems which are short-duration variations like instantaneous and momentary interruption and voltage sag by nature calamity ; typhoon, lightning, snow, etc. Besides, power quality ; harmonics, caused by using power electronics equipments, become a hot issue Malfunction of controller and stop machinery, and losing the important data are caused by poor power quality at a couple of second. Due to those, UPS, which is made up battery, has being used, but there are several disadvantages ; long charge and discharge time, environmental problem by acid and heavy metal, and short life time. As generally know, micro-SMES is a method to settle those mentioned. However, there need huge system apparatuses in order to verify the effect of system efficiency and stability considering the size of micro-SMES, the sort of converter type, and various conditions ; inner temperature, magnetic field, quench characteristic of micro-SMES, and etc. In this paper, in order to bring the mentioned above to a settlement, a micro-SMES is modeled with characteristics of micro-SMES is interfaced to EMTOC program using Fortran program interface method. We obtained hopeful answers and made the simulation model of micro SMES.

  • PDF

Rate Capability of Electric Double-Layer Capacitor (EDLC) Electrodes According to Pore Length in Spherical Porous Carbons

  • Ka, Bok-H.;Yoon, Song-Hun;Oh, Seung-M.
    • 전기화학회지
    • /
    • 제10권4호
    • /
    • pp.252-256
    • /
    • 2007
  • A series of spherical porous carbons were prepared via resorcinol-formaldehyde (RF) sol-gel polymerization in the presence of cationic surfactant (CTAB, cetyltrimethylammonium bromide), wherein the carbon sphere size was controlled by varying the CTAB introduction time after a pre-determined period of addition reaction (termed as "pre-curing"). The sphere size gradually decreases with an increase in the pre-curing time within the range of 30-150 nm. The carbons possess two types of pores; one inside carbon spheres (intra-particle pores) and the other at the interstitial sites made by carbon spheres (inter-particle pores). Of the two, the surface exposed on the former was dominant to determine the electric double-layer capacitor (EDLC) performance of porous carbons. As the intra-particle pores were generated inside RF gel spheres by gasification, the pore diameter was similar for all these carbons, thereby the pore length turned out to be a decisive factor controlling the EDLC performance. The charge-discharge voltage profiles and complex capacitance analysis consistently illustrate that the smaller-sized RF carbons deliver a better rate capability, which must be the direct result of facilitated ion penetration into shorter pores.

자연방전을 고려한 개선된 슈퍼커패시터의 동특성 모델 개발 (Development of the Improved Dynamic Model of the Supercapacitor Considering Self-Discharge)

  • 김상현;이교범;최세완;최우진
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.188-196
    • /
    • 2009
  • 슈퍼커패시터는 전력밀도가 높고 사이클 수명이 길며 깨끗한 특성으로 인해 신재생에너지원의 동특성 보상 및 배터리의 동작시간이나 수명연장을 목적으로 널리 사용되고 있다. 본 논문에서는 개선된 슈퍼커패시터의 동특성 모델을 전기화학적 임피던스 분광법(Electrochemical Impedance Spectroscopy)을 이용하여 개발한다. 개발된 모델은 슈퍼커패시터의 정확한 동적 행동을 예측하거나 특정 충전상태(State-Of-Charge)에서의 정확한 정전용량 값을 계산하는데 사용될 수 있다. 주파수영역에서 개발된 모델은 Matlab/Simulink 시뮬레이션을 위하여 시간영역으로 등가 변환된다. 시뮬레이션 결과는 실험 결과와 일치하였으며, 이를 통해 개발된 모델의 유용함과 정확성을 증명하였다.

시정수 비교기를 이용한 작은 크기의 위상고정루프 (Small-size PLL with time constant comparator)

  • 고기영;최영식
    • 한국정보통신학회논문지
    • /
    • 제21권11호
    • /
    • pp.2009-2014
    • /
    • 2017
  • 본 논문에서는 변화하는 루프필터 전압을 시정수 비교기를 사용하여 감지하고, 이의 출력에 따라 루프필터 전압변화를 보상하여 단일 칩으로 구현이 가능한 작은 크기의 위상고정루프를 제안하였다. 제안된 위상고정루프는 기존 구조에서는 안전한 동작이 불가능한 크기인 작은 용량을 가지는 커패시터를 사용하여 칩의 크기를 최소화 하였다. 시정수 비교기는 작은 시정수 값을 가지는 저항, 커패시터와 높은 시정수 값을 가지는 저항, 커패시터를 통과한 신호들을 입력으로 받아 루프필터 출력 전압의 변화를 감지한다. 시정수가 큰 노드의 출력은 루프필터 출력전압의 평균 값을 가지고, 시정수가 작은 노드의 출력은 루프필터 출력전압과 거의 같은 값을 가진다. 각 노드의 차이를 비교하여 나온 출력은 전류 보상기를 제어하여 작은 크기의 루프필터 커패시터를 충 방전 시킨다. 이는 제안된 위상고정루프를 안정하게 동작하도록 한다. 제안된 위상고정루프는 1.8V $0.18{\mu}m$ CMOS 공정을 사용하여 설계하였고, Hspice 시뮬레이션을 통해 회로의 동작을 검증하였다.

자궁적출술 환자를 위한 critical pathway 개발과 적용효과 (Critical Pathway Development for the Hysterectomy Patients and its applied Effect)

  • 노기옥;박경숙
    • 여성건강간호학회지
    • /
    • 제6권2호
    • /
    • pp.234-257
    • /
    • 2000
  • At present in the medical care, the study and effort for producing health service to consider efficiency, effectiveness, and quality are urgently called for because of the difficulty in the keen competition according to the inter- nationalization and opening, the operation in the medical institution service testing system, the change in the medical policy of KDRGs, and the lack of the health care cost increasing rate. As an alternative, the case management for the new management system is introduced in the U.S., and the Critical Pathway that is the method designing the contents of activity and its result has been developed and applied in order to anticipate and manage the patient-outcome for the realization of the cost-effective case-management. Thus, this study intended to analyze the effectiveness to obtain by developing the Critical Pathway presented as the method to improve the quality-betterment and cost effectiveness through the continuous and consistent patient management for the hysterectomy patient and applying it to the real practice. As a study method, this author formed a conceptual framework through considering five Critical Pathway used in the current U.S. and three Critical Pathway presented in the literature to develop the Critical Pathway for the hysterectomy patient, and made out the preliminary Critical Pathway through reviewing the old chart. This author made the verified the validity of the expert group about the developed Critical Pathway, and to confirm the possibility of practice application, completed and settled the final Critical Pathway after using the Critical Pathway to the hysterectomy patient from March 1st to 15th, 1997. Finally, to analyze the application-effect of the developed Critical Pathway, this author offered health care service applying the Critical Pathway to the hysterectomy patient from April 15th to August 31th, 1997. The guide for the Critical Pathway was carried out in advance by outpatient setting nurse for outpatient setting visit before the operation, and after hospitalization the primary nurse monitored the execution degree on the every duty. After discharge this author surveyed the complication through phone visiting, and one month after discharge surveyed the patient's reaction about the offered service when outpatient setting visit and analyzed the result. The source for health care cost was obtained by the statistics about the hospital charge which was offered by the General Business Department. The results were as follows. 1. It was decided that the vertical line of the Critical Pathway was made up of eight items such as monitoring/assessment, treatment, line/drains, activity, medication, lab test, diet, patient teaching, and the horizontal line of the Critical Pathway was made up of from hospitalization to discharge. 2. After the analysis of service contents through reviewing the old chart, it was decided that the horizontal line of the preliminary Critical Pathway was made up of from hopitalization to fourth postoperative day, and the vertical line of it was divided into eight items which were the contents to occur with the time frame of the horizontal line. 3. After the verifying the validity of the expert group about the preliminary Critical Pathway, the horizontal line was amended from hopitalization to third postoperative day, and taking their consensus, some contents of the horizontal line was amended and deleted. 4. From March 1st to 15th, 1997, to confirm the clinical suitability, this author offered eight hysterectomy patients the medical service through the Critical Pathway. The result was that three of them could be discharged at the expected discharge day, and the others later than that day. Supplementing the preliminary Critical Pathway through analyzing the cause of that delay- case, this author developed the final Critical Pathway. 5. There were no significant differences between the experimental and the control group in the incidence of complication(P > 0.05). 6. The 92.4% of experimental group was satisfied with the Critical Pathway service. 7. The length of hospital stay of the experimental group offered with the Critical Pathway service was 4.6 days and there was a significant difference that it was 1.3 days shorter than that of the control group(t=-29.514, P=0.000). 8. There wsa a significant difference that the mean medical charge per one patient of the experimental group offered the Critical Pathway service was cheaper \124,150 than that of the control group(t=-9.826, P=0.000). 9. The result that the author assumed and analyzed hospital income with the rate of turning bed was assumed that the increase of hospital income was \63,245,072 for that study, and the income increase was expected with \68,704,864 for a year. The result that this author applied the Critical Pathway to the hysterectomy patient have no differences in the incidence of complication, high satisfaction with that service, and the length of hospital stay decreased in the experimental group, and the mean hospital charge per one patient decreased, but hospital income increased. Suggestions for further study and nursing practice are as follows. 1. The study to apply the Critical Pathway for a year, verify the validity, and measure the effect repeatedly is needed. 2. To apply and manage the Critical Pathway effectively, the study to computerize it is needed. 3. The study to develop hospital-based Critical Pathway about other diseases or procedure, and measure the effect is needed.

  • PDF

Influence of Sustain Pulse-Width on the Electrical and Optical characteristics in AC-PDPs

  • Jeong, Y.W.;Cho, T.S.;Kim, T.Y.;Choi, M.C.;Ahn, J.C.;Jeong, J.M.;Lim, J.Y.;Choi, S.H.;Chong, M.W.;Kim, S.S.;Ko, J.J.;Kim, D.I.;Lee, C.W.;Kang, S.O.;Cho, G.S.;Choi, E.H.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.155-158
    • /
    • 2000
  • Influence of sustain pulse-width on electro-luminous efficiency is experimentally investigated for surface discharge of AC-PDP. A square pulse with variable duty ratio and rising time of 300 ns has been used in the experiment. It is found that the firing voltage is decreased as the pulse-width is increased from 2 ${\mu}s$ to 8 ${\mu}s$ with sweeping frequency range of 10 kHz to 50 kHz. It has been found that the optimal sustain pulse-width is in the range of $3{\sim}4{\mu}s$ under driving frequency range of 30 kHz and 50 kHz, based on observation of memory coefficient, wall charge, and wall voltage as well as luminous efficiency.

  • PDF

바나듐레독스흐름전지 전해질 유량에 따른 성능변화 (Effect of Electrolyte Flow Rates on the Performance of Vanadium Redox Flow Battery)

  • 이건주;김선회
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.324-330
    • /
    • 2015
  • The electrolyte flow rates of vanadium redox flow battery play very important role in terms of ion transfer to electrolyte, kinetics and pump efficiency in system. In this paper a vanadium redox flow battery single cell was tested to suggest the optimization criteria of electrolyte flow rates on the efficiencies. The compared electrolyte circulation flow rates in this experimental work were 15, 30 and 45 mL/min. The charge/discharge characteristics of the flow rate of 30 mL/min was the best out of all flow rates in terms of charging and discharging time. The current efficiencies, voltage efficiencies and energy efficiencies at the flow rate of 30 mL/min were the best. The IR losses obtained at thd current density of $40mA/cm^2$, at the flow rates of 15, 30 and 45 mL/min were 0.085 V, 0.042 V and 0.115 V, respectively. The charge efficiencies at the current density of $40mA/cm^2$ were 96.42%, 96.45% and 96.29% for the electrolyte flow rates of 15, 30 and 45 mL/min, respectively. The voltge efficiencies at the current density of $40mA/cm^2$ were 77.34%, 80.62% and 76.10% for the electrolyte flow rates of 15, 30 and 45 mL/min, respectively. Finally, the energy efficiencies at the current density of $40mA/cm^2$ were 74.57%, 77.76% and 73.27% for the electrolyte flow rates of 15, 30 and 45 mL/min, respectively. The optimum flow rates of electrolytes were 20 mL/min in most of operating variables of vanadium redox flow battery.

EDLC 전극용 메조기공 활성탄소 섬유의 전기화학적 특성 (The Electrochemical Characteristics of Mesopore Active Carbon Fiber for EDLC Electrode)

  • 강채연;신윤성;이종대
    • Korean Chemical Engineering Research
    • /
    • 제49권1호
    • /
    • pp.10-14
    • /
    • 2011
  • 철 이온 교환방법에 의해 메조기공을 갖는 활성탄소 섬유(ACF)를 제조하고, 이를 사용하여 전기 이중층 커패시터(EDLC)의 전극소재 성능을 조사하였다. 질산처리에 의해 제조된 메조기공 ACF는 비표면적이 1,249, 664 $m^2/g$이고, 메조 기공 분율이 70.6-81.3%이고, 평균 기공크기는 약 2.78~4.14 nm이다. 질산처리시간이 짧을수록 비표면적이 크고 메조 기공이 적게 발달됨을 알 수 있었다. 전기이중층 커패시터의 성능을 조사하기 위해서, 메조기공 ACF, 도전제, 바인더를 사용하여 단위 셀을 제조하였으며, 유기 전해질을 사용하였다. 2시간 질산으로 처리된 ACF의 비 축전양은 0.47 $F/cm^2$이고, 20회 충.방전 테스트에서 안정된 실험결과를 얻을 수 있었다. EDLC의 전기화학적 성능은 ACF 전극의 비표면적에 크게 영향을 받으며 메조기공은 전하의 확산저항을 감소시키는 것을 알 수 있었다.

페놀계 활성탄소섬유 전극과 유기성 전해질을 사용하는 전기이중층 캐패시터의 비축전용량 특성 (Specific Capacitance Characteristics of Electric Double Layer Capacitors with Phenol Based Activated Carbon Fiber Electrodes and Organic Electrolytes)

  • 안계혁;김종휘;신경희;노근애;김태환
    • 공업화학
    • /
    • 제10권6호
    • /
    • pp.822-827
    • /
    • 1999
  • 본 연구에서는 에너지 밀도가 큰 초고용량 캐패시터를 제작하기 위한 기초 연구로서 활성탄소섬유의 물성과 유기 전해질의 특성이 초고용량 캐패시터의 전기화학적 특성에 미치는 영향을 조사하였다. 유기성 전해질의 경우는 이온의 크기가 수용성 전해질 보다 훨씬 크기 때문에 탄소전극의 세공크기에 많은 영향을 받으며, 용량을 발현할 수 있는 유효세공의 크기가 커야 한다는 것을 알 수 있었다. 혼합용매를 이용한 전해액의 조성은 큰 비축전용량과 빠른 충전속도, 그리고 낮은 ESR 및 방전전류의 세기에 대한 높은 비축전용량 유지성 등의 우수한 충방전 특성을 나타내는 것을 알 수 있었고, 전해질의 높은 이온전도도가 용량발현 및 자가방전 특성에 큰기여를 하고 있으며, 전해질 이온의 크기는 충전속도에 많은 영향을 미치는 것을 알 수 있었다.

  • PDF