• 제목/요약/키워드: Discharge phenomena

검색결과 284건 처리시간 0.029초

AC 전압하에서 유리진공관의 방전현상 (Discharge Phenomena of Glass Tube Vacuum under AC Applied Voltage)

  • 최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.371-372
    • /
    • 2008
  • In this paper, we experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

Corona 방전에 의한 Polyethylene의 표면열화현상 (Surface Deterioration Phenomena in Polyethylene under Corona Discharge)

  • 성영권;송진수;민남기
    • 전기의세계
    • /
    • 제24권5호
    • /
    • pp.82-90
    • /
    • 1975
  • This study investigated the deterioration phenomena of the Polyethylene surface contaminated with organic(Saccharose) or inorganic(NaCl) matters through electrical and optical experiments. And also these experimental results relatively well coincided with which was treated by theoretical process. On the electrical experiment, relation between electric field intensity in corona discharge and time reached to the breakdown, and relation between total amount of charges discharged and increment of applied voltage were investigated. On the optical experiment, discharge time dependence of surface deterioration rate and process of surface deterioration in the X-ray diffraction pattern were investigated. It was concluded that chemical effects by the corona discharge deteriorated insulation characteristics of Polyethylene surface.

  • PDF

국산유기절연재료의 Treeing현상 (Treeing Phenomena in the Home-made Solid Organic Insulating Materials)

  • 성영권;이헌용;이계호;유기한
    • 전기의세계
    • /
    • 제26권2호
    • /
    • pp.57-65
    • /
    • 1977
  • In roder to investigate the influence of treeing on electric breakdown of solid organic insulator the initiation and growing mechanism of tree itself, and the correlation between corona discharge and treeing phenomena in solid orgainc insulating materials, several experiments were carried out by means of needle test on polymethyl-methacrylate. The obtained results showed that the existence of voids in specimen had important effects on initiation voltage of trees and, when the direct voltage was applied, the initiation voltage of trees increased by space charge effect. And also the stagnation phenomena due to the transfer of vacancy cluster or polymekr cage in specimen might beconsidered in process of growth of trees, and corona discharge seemed to be the pre-phenomena of treeing because trees were normally initiated by internal discharge in voids.

  • PDF

액체질소 중의 연면 방전과 트레킹 현상 (A Study on the Characteristics of the Surface Discharge and Tracking Phenomena in Liquid Nitrogen)

  • 신호영;윤대희;이상훈;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2320-2322
    • /
    • 1999
  • This paper was studied on the surface discharge characteristics and tracking phenomena on the solid insulator in liquid nitrogen ($LN_2$) at atmospheric pressure. In order to investigate the bubbles which have much influence on electric surface discharge in liquid nitrogen, Knife type electrode and plane electrode were arranged in different modes(Mode A, Mode B, and Mode C) and investigated for surface discharge and tracking phenomena. In Mode A, by the movement of bubbles tracking damage was formed under the electrodes. The tracking pattern in Mode B was formed along the electrode axis.

  • PDF

GITr(Gas Insulated Transformer) 내부에 발생되는 PD 신호의 패턴분석을 위한 PRPD와 CAPD 적용결과 비교 (A Comparative Study of The PD Pattern Analysis Based on PRPD and CAPD for The Diagnosis of Gas Insulated Transformer)

  • 정승용;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.308-312
    • /
    • 2006
  • Partial Discharge (PD) phenomena occurred by different nature of insulating defects has been regarded as a random process by which Phase Resolved Partial Discharge Analysis(PRPDA) has been proposed and then commercially accepted for the diagnosis of the power apparatus since more than three decades. Moreover, for the same purpose, a novel approach based on the Chaotic Analysis(CAPD) has been proposed since 2000, in which Partial Discharge(PD) phenomena is suggested to be considered as a deterministic dynamical process. In this work, for the diagnosis of Gas Insulated Transformer(GITr), four different types of specimen were fabricated as a model of the possible defects that might possibly cause its sudden failures such as turn to turn insulation, inter coil insulation, free moving particle and protrusion. For this purpose, these defects are introduced into the Gas Insulated Transformer(GITr) mock-up and experimental investigations have been carried out in order to analyze the related Partial Discharge(PD) patterns by means of both Phase Resolved Partial Discharge Analysis(PRPDA) and Chaotic Analysis(CAPD) respectively and then their comparisons are made systematically.

대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상 (The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in $LN_{2}$ at the Atmospheric Pressure)

  • 박경태;신호영;박광서;최병주;이광식;이동인
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.114-118
    • /
    • 2002
  • This paper were investigated discharge characteristics in the Liquid Nitrogen($LN_{2}$) noticed as a cooling medium of high temperature superconductor, and the characteristics of surface discharge and tracking phenomena on the solid insulators of cryocable. In order to investigate the bubbles which have much influence on electric surface discharge in Liquid Nitrogen, knife type electrode and plane electrode was formed oppositely with mode A and B, C configuration. It is considered that these result are fundamental data for electric insulation design of superconductivity and cryogenic application machinery which will be studied and developed in the future.

  • PDF

교류전압하에서 저압 진공관의 방전현상 (Discharge Phenomena of Low Pressure Vacuum under AC Applied Voltage)

  • 전진;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2301-2302
    • /
    • 2008
  • We experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and SF6. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

2차 전자방출 효과를 고려한 기체방전의 과도상태 유한요소해석 (Finite Element Analysis of Gas Discharge in Transient State Considering Secondary Electron Emission Effects)

  • 김남경;정기우;최낙선;이세희;김동훈
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1276-1281
    • /
    • 2010
  • To analyze the gas discharge phenomena in parallel-plane electrodes, the fully coupled finite element method (FEM) considering secondary electron emission effects in discharge column was adopted in this paper. Two coupled equations of the hydrodynamic diffusion-drift equations for three carriers and the Poisson's equation for electric scalar potential should be solved as a system equation. The proposed method including two secondary electron processes of the photoemission and background ionization has been successfully applied to evaluating the breakdown voltage in parallel-plane electrodes and is verified by comparing its numerical results with the experimental ones. From the obtained results, it is inferred that the proposed numerical scheme will be useful for predicting and understanding streamer transient phenomena.

저항률에 따른 수중방전 특성에 관한 연구 (A Study of underwater discharge characteristics in different resistivity)

  • 이복희;최종혁;이강수;;;안창환;정용기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.254-255
    • /
    • 2007
  • This paper describes underwater discharge phenomena which are less studied than gas, solid and dielectric liquid. Since discharge phenomena were affected by various factors, we investigated the effect of water resistivity in point-plane gap by impulse voltage. In discharge photograph, it is hard to discover the streamer development in positive polarity at high reisistivity. On the other hand, the streamer originated at the tip of rod and developed toward the plane with increasing voltage. It is found that the breakdown voltage of both polarities in lower resistivity are lower than that of high resistivity. High current flowing in lower resistivity before the breakdown induce more streamer and enhance the probability of breakdown.

  • PDF

유기 가스중 고주파 글로우가전 특성에 관한 연구 (The Study on Characteristics of High Frequency Glow Discharge in Organic Vapor)

  • 이덕출;김은배;박상현;박종대
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.355-360
    • /
    • 1985
  • In this paper, the discharge phenomena of high frequency glow discharge in organic vapor are basically investigted to establish the growth mechanism and preparation technique for organic thin film. According to the increasing of discharge frequency, the discharge firing voltage(Vs) of organic vapor decreases. The dependence of discharge voltage(Vd) on gas pressure is generally in accord with Paschen's Law and Vd decreases as gas flow rate become larger, but increases as dischange current density become higher. And the values of Vd in organic vapor are generally higher than those of inorganic gas.

  • PDF