• Title/Summary/Keyword: Discharge method

Search Result 3,036, Processing Time 0.031 seconds

A Study on the River Discharge Measurement Techniques (하천유량 측정기법에 관한 연구)

  • 김성원;지홍기
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

A Study on Estimation by Depth Integrating Method of Sediment Discharge (수심적분법에 의한 유사량 추정연구)

  • 서승덕;김활곤;우효섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.1
    • /
    • pp.90-97
    • /
    • 1996
  • In Korea, total sediment discharge of a river has been estimated simply by using certain sediment transport formulas including, among others, Einstein's formula. Those formular, however, are known not to be reliable enough for the result calculated by them to be used directly to river planning and management. Therefore, the study used the Modified Einstein Procedure to the estimation of total sediment discharge, because this method is reliable estimated by measurement. Here, measurement of sediment discharge used depth integrating method. The major results obtained from the study for estimation by depth integrating method of sediment discharge in Naeseong stream are as follow; 1 The sedeiment characteristics of Naeseong stream are; The distribution of sediment grain size shows that silt and clay are 55% and sand is 45%. and the bed load sediment grain size is constituted that sand contained with the grain size from O.062mm to 2.0mm is 80% 2. The sediment rating formulas derived from the regression analysis between the sediment discharge and flow discharge are; Seogpo-Gyo : Qs=$0.017 \times 10^{-4} Q^{2.352}$, where discharge is l0cms $0.074 \times 10^{-4} Q^{2.066}$, where discharge is l0cms

  • PDF

A Method for Determination of 3D-Electrical Discharge Machining Parameters Using Z-map (Z-map을 이용한 3차원 방전가공조건의 결정방법)

  • 주상윤;이건범
    • Korean Journal of Computational Design and Engineering
    • /
    • v.4 no.4
    • /
    • pp.355-359
    • /
    • 1999
  • This paper presents a method for determining machining parameters in electrical discharge machining process (EDM) based on discharge area. The parameters are the peak value of currents, the pulse-on time, and the pulse-off time, on which the EDM performance depends chiefly. The optimal machining parameters are closely related on discharge area, which can be calculated from a tool electrode and a discharge height. In the paper the discharge area is obtained from NC code for machining the tool electrode instead of its geometric model. The method consists of following three steps. First a Z-Map model is constructed from the NC code. Secondly, the discharge area is obtained from the Z-Map model and a Z-height. Finally, the machining parameters are calculated from the discharge area. An introduced example shows that the machining parameters are calculated by the using a Z-map model obtained from the machining data for a tool electrode.

  • PDF

A Study on the New Discharge AND Gate and Drive Scheme for the Cost Down of the PDPs (PDP의 가격절감을 위한 새로운 방전 AND Gate 및 구동기술에 관한 연구)

  • 염정덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.6
    • /
    • pp.267-273
    • /
    • 2003
  • The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

Study on Characteristics of Write Discharge with Single Sustain Waveform in AC Plasma Display Panel (교류형 플라즈마 디스플레이에서 단일 유지 파형을 가지는 기입 방전의 특성의 연구 )

  • Byung-Gwon Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.56-61
    • /
    • 2023
  • The characteristics of write discharge were investigated when the conventional driving method with the unipolar sustain voltages, and the single sustain driving method applying the bipolar sustain voltage were applied in an AC plasma display. In the case of having a single sustain waveform, the strength of the write discharge is weakened compared to the conventional driving method during the address period, because the wall charge inside the panel is more dissipated by the lower scanning voltage. In the driving method with a single sustain waveform, the bias voltage of the other electrodes was changed to improve the write discharge characteristics. As a result, the intensity of the discharge was enhanced by 32% and the delay time was shortened by 60 ㎲.

Estimation of Design Flood Considering Time Distribution of Rainfall (강우 시간분포를 고려한 설계홍수량산정)

  • Park, Jae-Hyun;Ahn, Sang-Jin;Hahm, Chang-Hahk;Choi, Min-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1191-1195
    • /
    • 2006
  • Now days, heavy storm occur to be continue. It is hard to use before frequency based on flood discharge for decision that design water pocket structure. We need to estimation of frequency based on flood discharge on the important basin likely city or basin that damage caused by flood recurrence. In this paper flood discharge calculated by Clark watershed method and SCS synthetic unit hydrograph method about upside during each minute of among time distribution method of rainfall, Huff method choosing Bocheong Stream basin that is representative basin of International Hydrologic Project (IHP) about time distribution of rainfall that exert big effect at flood discharge estimate to research target basin because of and the result is as following. Relation between probability flood discharge that is calculated through frequency analysis about flood discharge data and rainfall - runoff that is calculated through outward flow model was assumed about $48.1{\sim}95.9%$ in the case of $55.8{\sim}104.0%$, SCS synthetic unit hydrograph method in case of Clark watershed method, and Clark watershed method has big value overly in case of than SCS synthetic unit hydrograph method in case of basin that see, but branch of except appeared little more similarly with frequency flood discharge that calculate using survey data. In the case of Critical duration, could know that change is big area of basin is decrescent. When decide time distribution type of rainfall, apply upside during most Huff 1-ST because heavy rain phenomenon of upsides appears by the most things during result 1-ST about observation recording of target area about Huff method to be method to use most in business, but maximum value of peak flood discharge appeared on Huff 3-RD too in the case of upside, SCS synthetic unit hydrograph method during Huff 3-RD incidental of this research and case of Clark watershed method. That is, in the case of Huff method, latitude is decide that it is decision method of reasonable design floods that calculate applying during all $1-ST{\sim}4-TH$.

  • PDF

Estimation of Flood Discharge Based on Observation Data Considering the Hydrological Characteristics of the Han Stream Basin in Jeju Island (한천유역의 수문학적 특성을 고려한 관측자료 기반 홍수량 산정)

  • Yang, Sung-Kee;Kim, Min-Chul;Kang, Bo-Seong;Kim, Yong-Seok;Kang, Myung-Soo
    • Journal of Environmental Science International
    • /
    • v.26 no.12
    • /
    • pp.1321-1331
    • /
    • 2017
  • This study reviewed the applicability of the existing flood discharge calculation method on Jeju Island Han Stream and compared this method with observation results by improving the mediating variables for the Han Stream. The results were as follows. First, when the rain-discharge status of the Han Stream was analyzed using the flood discharge calculation method of the existing design (2012), the result was smaller than the observed flood discharge and the flood hydrograph differed. The result of the flood discharge calculation corrected for the curve number based on the terrain gradient showed an improvement of 1.47 - 6.47% from the existing flood discharge, and flood discharge was improved by 4.39 - 16.67% after applying the new reached time. In addition, the sub-basin was set separately to calculate the flood discharge, which yielded an improvement of 9.92 - 32.96% from the existing method. In particular, the steepness and rainfall-discharge characteristics of Han Stream were considered in the reaching time, and the sub-basin was separated to calculate the flood discharge, which resulted in an error rate of -8.77 to 8.71%, showing a large improvement of 7.31 - 28.79% from the existing method. The flood hydrograph also showed a similar tendency.

A Study on Discharge Estimation by Representative Parameter Method in Open Channels (개수로에서의 대표 매개변수 방법에 의한 유량산정에 관한 연구)

  • Choo, Tai Ho;Chae, Soo Kwon
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.637-644
    • /
    • 2012
  • The discharge estimation that means the most important element in a wetlands ecosystem and rivers is a prime concern. All the interim, this discharge estimation depends on stage-discharge curve, but the limitation of stage-discharge curve that uses only connection between the stage and discharge is widely well known. Thus, this paper proposed a method of discharge estimation in a section through "representative parameter estimation method" by using Manning and Chezy equations that have been extensively used in an open channel. Each result is presented by both RMSE and Discrepancy Ratio. The scale difference for the results between laboratory and natural open channel data existed, but the each result showed that the estimated discharge agree with the measured discharge. If the verification and improvement are conducted in various rivers through continuous study, the easy and rapid discharge estimation will be possible. So, the proposed method will be utilized in the water resources fields.

The Characteristics of the Discharge According to ITO Gap by the CLHS Driving Method in AC PDP (AC PDP에서 CLHS 구동 방법에 의한 ITO Gap에 따른 방전 특성)

  • Shin, Jae-Hwa;Choi, Myung-Gyu;Kim, Gun-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.83-89
    • /
    • 2013
  • In order to reduce the power consumption in international standard IEC62087, the luminance efficiency should be improved at the low discharge load rather than at the high discharge load. Thus, this paper analysed the characteristics of the discharge at the panels with ITO Gap of $65{\mu}m$, $80{\mu}m$, and $100{\mu}m$ in 50-inch PDP with FHD resolution. It was well known that the long gap panel improves the luminance and the luminous efficiency. However, it is very difficult to drive the panel due to high driving voltage. When the normal driving method was applied at the panel with ITO gap of $100{\mu}m$, the phenomenon of the double peak was generated in the sustain period. We confirmed that main factor of the double peak is the self-erasing discharge. When the CLHS driving method was applied at the panel with ITO gap of $100{\mu}m$, the self-erasing discharge was improved in the sustain period. Also, the $V_S$ and $V_A$ minimum voltage of the CLHS driving method decreased about 9V and 12V compared with those of the normal driving method. Moreover, when the CLHS driving method was applied to the panel with ITO gap of $100{\mu}m$, the luminance and the luminous efficiency increased compared with those of the normal driving method. The luminance and the luminous efficiency greatly increased at the low discharge load. The less discharge load, the higher increase rate of the luminance and the luminous efficiency. Especially, the luminous efficiency at ITO gap of $100{\mu}m$ increased about 26.3% at the discharge load of 4% compared with that at ITO gap of $65{\mu}m$.

ORGANIC POLLUTANTS DEGRADATION USING PULSELESS CORONA DISCHARGE: APPLICATION IN ULTRAPURE WATER PRODUCTION

  • Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.144-154
    • /
    • 2005
  • The use of ozone gained acceptance in the production of ultrapure water because of its powerful oxidizing ability. Ozone is currently used to deactivate microorganisms and remove organic contaminants. However, interest also exists in using radical species, which arc stronger oxidants than ozone, in such processes. One means of producing radical species is by corona discharge. This work investigates the use of a novel pulseless corona-discharge system for the removal of organic substances in ultrapure water production. The method combines corona discharge with electrohydrodynamic spraying of oxygen, forming microbubbles. Experimental results show that pulseless corona discharge effectively removes organics, such as phenol and methylene blue, in deionized water. The corona-discharge method is demonstrated to be comparable to the direct use of ozone at a high-applied voltage. The results also show that a minimum applied voltage exists for operation of the corona-discharge method. In this work, the minimum applied voltage is approximately 4.5 kV. The kinetic rate or phenol degradation in the reactor is modeled. Modeling results show that the dominant species of the pulseless corona-discharge reactor are hydroxyl radical and aqueous electron. Several radical species produced in the pulseless corona-discharge process are identified experimentally. The. major species are hydroxyl radical, atomic hydrogen species, and ozone.