• Title/Summary/Keyword: Discharge gap

Search Result 426, Processing Time 0.028 seconds

Effects of Nanopowder Additives in Micro-electrical Discharge Machining

  • Tan, Peng-Cheong;Yeo, Swee-Hock;Tan, Yie-Voon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.22-26
    • /
    • 2008
  • The use of electrical discharge machining (EDM) for micro-machining applications requires particular attention to the machined surface roughness and discharge gap distance, as these factors affect the geometrical accuracy of micro-parts. Previous studies of conventional EDM have shown that selected types of semi-conductive and non-conductive powder suspended in the dielectric reduced the surface roughness while ensuring a limited increase in the gap distance. Based on this, an extension of the technique to micro-EDM was studied Such work is necessary since the introduction of nanopowders suspended in the dielectric is not well understood. The experimental results showed that a statistically significant reduction in the surface roughness value was achieved at particular concentrations of the powder additives, depending on the powder material and the machining input energy setting. The average reduction in surface roughness using a powder suspended dielectric was between 14-24% of the average surface roughness generated using a pure dielectric. Furthermore, when these additive concentrations were used for machining, no adverse increase in the gap distance was observed.

A Study on the Characteristics of High Pressure DC Glow Discharge with a Narrow Gap (좁은 간격의 고압 DC 글로우 방전에서의 방전물성에 관한 연구)

  • Park, Jae-Seong;Jeong, Heui-Seob;Shin, Buhm-Jae;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.435-437
    • /
    • 1995
  • It is important to understand tile behaviours of tile high pressure DC glow discharge with a micro gap inside a pixel of the plasmas display panel. We prepared a narrow gap discharge system and have measured electron temperature and density by means of double probe methods in high pressure which was between 100torr and 200torr. And the electrode gap was 7mm. When the pressure varied from 100torr to 200torr, the negative glow was created at a distance less than 1mm from the cathode. And the length of the faraday dark space decreased from 8mm to 5mm. Hence probe measurements was mainly, performed in the region of the Faraday dark space. The dependence of electron temperature and density on the pressure and current density was same with that of the general flow discharge, i.e. as the pressure increased the electron temperature decreased and the density increased. But the spatial electron density distribution in the Faraday dark space was highly distorted because of the effect of high pressure.

  • PDF

New Reset Waveform for a Large-Sustain-Gap Structure in AC PDPs (AC PDP의 장방전 구조의 구동을 위한 새로운 리셋파형)

  • Kim, Sun;Kim, Dong-Hun;Song, Tae-Yong;Kim, Ji-Yong;Lee, Seok-Hyun;Seo, Jeong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1544-1545
    • /
    • 2006
  • In this paper, we present a new reset waveform for a large-sustain-gap structure in at PDPs. In the driving of the large-sustain-gap structure with a conventional ramp reset waveform, we cannot avoid the condition of an address being a cathode, which causes lots of trouble in stabilizing a reset discharge. To solve these problems, we use the square pulse instead of the conventional rising ramp pulse. Before making a strong discharge between the address (cathode) and scan (anode) electrodes, we make a priming discharge between the address (anode) and the scan (cathode) electrodes to stabilize the strong discharge in which the address electrodes are the cathode. With this scheme, we obtained 60V minimum address voltage and 145V maximum address voltage in $250{\mu}m$ and $350{\mu}m$ gap structures.

  • PDF

Analysis on the Discharge Characteristics of AC Plasma Display Panel with Counter Sustain Electrodes (교류형 플라즈마 표시기의 신 대향형 구조에 대한 방전 특성 분석)

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1579-1583
    • /
    • 2008
  • We proposed the new structure of ac plasma display panel(PDP) to improve the luminous efficacy and driving voltage characteristics. Through two-dimensional numerical simulations, we analyzed the effects of new counter discharge type, which consists of counter sustain electrodes and auxiliary electrodes. Generally, an advantage of AC PDP with the counter sustain electrodes has been known for the driving characteristics of the low voltage. In this work, the new counter structure using the ignition discharge by the auxiliary pulse applied to the address electrode showed the result of the increased luminous efficacy. The short gap discharge between two auxiliary electrodes on the front plate could intensity the long gap discharge between counter electrodes. The reliability of simulation result could be confirmed by the experimental result in the test panel.

A Study on Ozone Generation Characteristic using Ba-Ti-Si Ceramic Tube (Ba-Ti-Si 세라믹 방전관의 오존 발생 특성 연구)

  • 이동훈;박홍재;박재윤
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.634-640
    • /
    • 2003
  • This paper is to be researched into ozone generation character of Bi-Ti-Si type high dielectric yield ceramic catalyst discharge tube. And conditions of basic experiment are the outside diameter of discharge tube : 52 mm, the length of discharge tube : 350 mm, the frequence : 900 Hz, the temperature of cooling water : 25 $^{\circ}C$, quantity of flow : 5, 10, 20 l/min, pressure : 1.2, 1.4, 1.6 atm, and distance of discharge gap : 0.4, 0.6, 0.8 mm. Ozone generation characteristics were measured to consumption power. At quantity of flow : 20 l/min, discharge gap : 0.6 mm, pressure : 1.6, and consumption power : 150 W, Maximum ozone generation efficiency of 175 g/kWh was obtained. Maximum ozone generation efficiency was measured below the flow quantity of 20 l/min at below pressure of 1.6 atm. However, Maximum ozone generation efficiency was measured over the flow quantity of 20 l/min at over pressure of 1.6 atm.

Fabrication of Atmospheric Coplanar Dielectric Barrier Discharge and Analysis of its Driving Characteristics (평면형 대기압 유전장벽방전장치의 제작 및 동작특성분석)

  • Lee, Ki-Yung;Kim, Dong-Hyun;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.80-84
    • /
    • 2014
  • The discharge characteristics of Surface Dielectric Barrier Discharge (SDBD) reactor are investigated to find optimal driving condition with adjusting various parameter. When the high voltage with sine wave form is applied to SDBD source, successive pulsed current waveforms are observed owing to multiple ignitions through the long discharge channel and wall charge accumulation on the dielectric surface. The discharge voltage, total charge between dielectrics, mean energy and power are calculated from measured current and voltage according to electrode gap and dielectric thickness. Discharge mode transition from filamentary to diffusive glow is observed for narrow gap and high applied voltage case. However, when the diffusive discharge is occurred with high applied voltage, the actual firing voltage is always lower than that with low driving voltage. The $Si_3N_4$, $MgF_2$, $Al_2O_3$ and $TiO_2$ are considered for dielectric protection and high secondary electron emission coefficient. SDBD with $MgF_2$ shows the lowest breakdown voltage. $MgF_2$ thin film is proposed as a protection layer for low voltage atmospheric dielectric barrier discharge devices.

Development of Ozone Generation Technology Using Gaseous Electrical Discharge for Environment Improvement (환경개선용 기체전기방전을 이용한 오존발생기술 개발)

  • 이동헌;송현직;구건효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.25-34
    • /
    • 2001
  • In this paper, discharge lamp ozonizer(DLO) of a new discharge type using superposition of gaseous electrical discharge for environment improvement was designed and manufactured. DLO is equipped with 3 electrodes(central ground electrode of discharge lamp type internal high voltage electrode of mesh type and external high voltage electrode of spiral type), and it is composed of double gap(gap between discharge lamp and internal electrode, gap between discharge lamp and external electrode). Internal and external electrodes are respectively applied AC high voltage which has 180[$^{\circ}$] phase difference. Ozone is generated by overlaying of each silent discharge which is respectively came from two gaps. At the moment discharge characteristics and ozone generation characteristics of DLO were investigated in accordance with quantity of supplied gas, discharge power and the number of DLO. When ozone generated by DLO was in contact with NO gas, removal characteristics was excellent, so it confirmed that DLO could be used as air environment improvement facility.

  • PDF

Efficient Arc Detection and Control Method in Electro-discharge Machining (방전가공기의 효율적인 아크 검출과 제어방법)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.309-315
    • /
    • 2018
  • In this paper, propose an efficient arc detection and control method to achieve fast machining speed, improved precision and surface roughness in discharge machining, especially for carbide and hard material processing and metal processing using discharge phenomenon as energy. A single discharge waveform is divided into three sections of Td (Time-Delay), Ton (Time-on) and Toff (Time-off) and the gate control timing is simulated using the HDL language. In this paper, we analyze the effect of the gap between the electrode and the workpiece on the machining results by determining the operation of the servo mechanism by sampling the Td section through the comparator circuit. As a result of the analysis, the Td section of the formed waveform was more precisely sampled at a high speed and the results were improved when applied to the gap control between the electrode and the workpiece.

Effect of Discharge Gas on the Electrical Characteristics of the Glow Discharge Plasma for the Gas Chromatographic Detector (글로우방전 가스크로마토그라프 검출기에서 방전가스의 영향)

  • 박현미;강종성;김효진
    • YAKHAK HOEJI
    • /
    • v.39 no.5
    • /
    • pp.480-486
    • /
    • 1995
  • The change in discharge current of a glow discharge has been shown the potential sensitive detector for gas chromatography. To investigate the effect of carrier gas on the electrical characteristics of the discharge and the peak response, the discharge pressure, gas flow rate, and discharge gap have been studied. The discharge gas included the Ar, He, and N$_{2}$. The gas flow rate has been found one of the important parameters to affect both the electrical characteristics and the peak response.

  • PDF

Effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap

  • Park, Sang-Dae;Lee, Seung-Hun;Shin, Nam-Hoon;Lee, Kyo-Sung;Park, Sung-Yun;Kim, Sang-Ho;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.109-112
    • /
    • 2004
  • The effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap was investigated. The auxiliary electrode was placed between scan and common electrode. When the pulse was applied to the auxiliary electrode during sustain period, the luminance of Ne + 13%Xe gas-mixture discharge increased and the discharge current decreased. The auxiliary pulse plays a role of improving electron excitation efficiency. When the auxiliary pulse was applied during address period, the address discharge time lag of Ne + 13%Xe gas-mixture could be reduced remarkably.

  • PDF