• Title/Summary/Keyword: Discharge gap

Search Result 426, Processing Time 0.031 seconds

Evaluation of Pile Spacing Ratio of Stabilizing Piles for Ground Destruction Reduction at the Time of Soft Ground Excavation (연약지반 굴착시 지반파괴 저감을 위한 억지말뚝의 간격비 평가)

  • Kim, Jae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.47-56
    • /
    • 2016
  • In the case of excavating ground backfilled with soft ground, ground destruction occurs owing to the discharge of groundwater from excavated back ground in spite of earth retaining wall. To minimize this, indoor model test was implemented applying stabilizing pile as a solution for ground destruction. The unreinforced case was compared with the reinforced case and the comparison demonstrated that the ratio of the gap in settlement of the two cases is about three to one, which proves the reinforcement effect (Kim, 2014). This study has carried out the evaluation of appropriate pile spacing ratio, according to the confirmed effect of stabilizing pile. In the evaluation test the case with pile spacing ratio of 0.66 (5 stabilizing piles) was compared with that of 0.76 (3 stabilizing piles), and it has been shown that applying stabilizing pile has effect on ground destruction reduction, but may rather work as load when pile spacing ratio is narrower than a certain interval. So it was found that adjustment for appropriate pile spacing ratio is required at the stage of design. This study has shown that the pile spacing ratio is appropriate at around 0.7~0.8, which reduces ground destruction and does not function as the load of excavated back ground.

AC Breakdown Voltage Characteristics of $SF_6/CF_4$ and (E/P)crit in quasi-uniform Field (준평등전계에서 $SF_6/CF_4$ 혼합가스의 절연 파괴 전압 및 임계전계 특성)

  • Lee, Byung-Taek;Hwang, Cheong-Ho;An, Jung-Sik;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1455_1456
    • /
    • 2009
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in quasi-uniform field was performed. This experiments were carried out under AC voltages. The rod-rod electrode was used with 5 mm gap distance. The mixture of $SF_6/CF_4$ containing 20%,50%,70% of $SF_6$ were compared with pure $SF_6$ and $CF_4$ gas and gas pressure ranged from 0.1 to 0.5 MPa. The show that the breakdown voltages of gas were linearly increased according to the pressure in quasi-uniform field. For breakdown vlotage values of $(E/P)_{crit}$ are important. Because If values of (E/P) is a little more than $(E/P)_{crit}$, electrons rapidly increase and streamer discharge gernerates. Through this experiments values of $(E/P)_{crit}$ are found to vary with the ratio of $SF_6/CF_4$ mixture according to the following relationship. $V_b=(E/P)_{crit}{\cdot}p{\cdot}d$

  • PDF

Study on Validity and Reliablity of the Cutoff Probe and Langmuir Probe via Comparative Experiment in the Processing Plasma

  • Kim, D.W.;You, S.J.;You, K.H.;Lee, J.W.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.576-576
    • /
    • 2013
  • Recently, diagnostics of plasma becomes more important due to requirement of precise control of plasma processing based on measurement of plasma characteristics. The Langmuir probe has been used for the diagnostics but it has an inevitable uncertainty and error sources such as incorrect tip length and RF noise. Instead of the Langmuir probe, various diagnostic methods have been developed and researched. The cutoff probe is promising one for plasma density using microwaves and resonance phenomenon at the plasma frequency. The cutoff probe has various advantages as follows; (i) it is simple and robust, (ii) it uses few assumptions, and (iii) it is free from deposition by reactive gas. However, the cutoff probe also has uncertainty and error sources such as gap between tips, tip length, direction of tip plane, and RF noise. In this study, the uncertainty and error sources in manufacturing both probes and in diagnostics process were analyzed via comparative experiment at various discharge conditions. Furthermore, to reveal the user dependence of both probes, three well trained Ph. D students made the Langmuir probe and the cutoff probe, respectively, and it were analyzed. Thought this study, it is established that reliability and validity of the Langmuir probe and the cutoff probe related with not only the intrinsic characteristics of probes but also probe user.

  • PDF

Groundwater Balance in Urban Area (도시지역의 지하수수지)

  • Lee, Seung-Hyun;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1553-1560
    • /
    • 2011
  • The study analyzes groundwater balance with regard to the water recharge and discharge which contain urbanization components in Suyeong-gu, Busan. It also verifies the reliability and accuracy improvement on the analysis of the balance. The result of the study is viewed as preliminary data which are useful to develop, utilize and manage groundwater. The average quantity of groundwater recharge is 6,014.1 $m^3$/day in the research area during the last ten year period(from 1998 to 2007). The outflow from drainage areas to rivers and coasts is 149.3 $m^3$/day, the inflow from rivers and coasts to drainage area is 439.9 $m^3$/day. The use of the water is 4,243.0 $m^3$/day. The outflow caused by subway in line No.2 and No.3 through Suyeong-gu and the one by building an underground electric complex is 1,500.0 $m^3$/day. The leakage of water works is 6514.9 $m^3$/day. The inflow and outflow of sewerage is 5082.2 $m^3$/day from groundwater to sewer. The amount of groundwater recharge, the inflow from rivers and coasts to drainage area, and the leakage of water works belong to the amount of groundwater inflow and the total amount is 12,968.9 $m^3$/day. The amount of outflow from drainage area to rivers and coasts, the use of groundwater, outflow by subway and underground electric complex tunnel and the amount of inflow of the water to sewerage belong to the amount of outflow of groundwater and the sum amount is 13,031.5 $m^3$/day. The gap between the amount of inflow and outflow of groundwater is 62.6 $m^3$/day, which is considered to reflect the trend that the short term drop in the amount of rainfall results in the amount of groundwater recharge and that the amount of outflow from drainage area to rivers and coasts decreases.

Numerical Modeling of Very High Frequency Multi Hollow Cathode PECVD (Very High Frequency Multi Hollow Cathode PECVD 장치의 수치모델링)

  • Joo, Jung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.331-340
    • /
    • 2010
  • 3D fluid based numerical modelling is done for a VHF multi hollow cathode array plasma enhanced chemical vapor deposition system. In order to understand the fundamental characteristics of it, Ar plasma is analyzed with a condition of 40 MHz, 100 Vrf and 1 Torr. For hole array of 6 mm diameter and 20 mm inter-hole distance, plasma is well confined within the hole at an electrode gap of 10 mm. The peak plasma density was $5{\times}10^{11}#/cm^3$ at the center of the hole. When the substrate was assumed at ground potential, electron temperature showed a peak at the vicinity of the grounded walls including the substrate and chamber walls. The reaction rate of metastable based two step ionization was 10 times higher than the direct electron impact ionization at this condition. For $H_2$, the spatial localization of discharge is harder to get than Ar due to various pathways of electron impact reactions other than ionization.

Negative Pressure Wound Therapy Applied to a Meshed Split-Thickness Skin Graft

  • Lee, Dong-Hun;Kim, Yu-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.2
    • /
    • pp.29-36
    • /
    • 2016
  • Purpose: Skin grafting is used for the transfer of cutaneous tissue from one site of the body to another. To improve graft survival, close contact between the graft and the wound bed is essential for vessels to grow across the gap. Here, we introduce an easy and efficient dressing method to improve graft survival. Materials and Methods: A retrospective chart review was performed to identify patients who underwent split thickness skin graft and negative pressure wound therapy (NPWT) or conventional treatment between January 2007 and April 2015. Overall, 25 consecutive patients were included in the NPWT group and 49 were included in the conventional dressing group to compare the outcome of the procedure. The data were obtained from medical records, including age, sex, cause of the skin defect, size of graft, time for healing, wound preparation time, and complications. Results: Of the NPWT group, the average wound size was $147.04{\pm}146.74cm^2$ (range, $9{\sim}900cm^2$). With the exception of one patient, all wounds healed without the need for further procedure. The average duration of time required for the NPWT group, which was defined as removal of stitches (or staples) and no need for additional active dressing, was $6.4{\pm}1.97days$ (range, 5~15 days). The average time for the conventional dressing group was $10.78{\pm}2.38days$ (range, 5~15 days). Conclusion: NPWT can be used to cover regions in which wound healing does not occur fully or when neither tie-over nor compressive dressings are applicable. This treatment also reduced wound healing time and allowed earlier patient mobilization and hospital discharge.

Characterization of the Hydrogen Reservoir for a High Power Gas Switch

  • Lee, Byeong-Jun;Park, Seong-Su;Kim, Sang-Hui;Gwon, Se-Jin;Jang, Seong-Deok;Mun, Yong-Jo;Ju, Yeong-Do;Kim, Chang-Beom;Hwang, Il-Mun;Sin, Seung-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.547-547
    • /
    • 2013
  • This paper presents the understandings carried out for the installation of the hydrogen reservoir of the multi-gap pseudospark switch under developing for the accelerator applications. As a cold cold cathode switch, the pseudospark switch could replace the thyratron switch which has hot cathode and being used well currently in the high power field such as laser and accelerator applications. Especially in the klystron modulator, the key component is a switch which mostly defines the jitter and the instability of the modulator system. To get the less jitter and the instability, we need to find proper range of the pressure for the gas discharge inside gas switch. This could be achieved by the understanding of the characteristic of the nonevaporable getter (NEG) which is used as a hydrogen reservoir for the switch. Therefore we verified the characteristics of the NEG (St 172, Saes) and its installation in the switch. Finally we controlled the getter to find best pressure point for the pseudospark switch.

  • PDF

A Study on Production of Nitrogen Oxides in Plasma Reactors

  • Lim, Gye-Gyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E3
    • /
    • pp.91-99
    • /
    • 2001
  • Plasma reactor was used to generate a high potential difference between two surfaces of concentric pyrex tubes by electrical current. The annular gap of the reactor was calculated by trial and error from the breakdown voltage equation and set at 0.45 cm. The overall objective of this research was to know the effects of the frequency, humidity, and residence time on the formation of nitrogen oxides in a plasma reactor. The primary voltage varied from 50 to 90 volts and the frequency was varied in increments of 10 Hz from 60 to 650 Hz at the primary voltage of 90. The increase in the secondary voltage was not linear but exponential at high frequencies. At a maximum concentration of about 745 ppm, the frequency and secondary voltage was 600 Hz and 4,200 volts, respectively. All tests for the effects of humidity on NO$_{x}$ production were performed at the optimal setting of 90 colts and 600 Hz frequency. Since the NO$_{x}$ production was not an one dimensional phenomenon, competing reactions were assumed to occur in the discharge chamber. The sharp peak concentration of 1,810 ppm was observed at 38% of relative humidity, The enhanced production was choked off, and the production rate rapidly dropped to 3 ppm at above 40% of relative humidity. It is assumed that the corona attacks the most vulnerable molecules in the reaction chamber before attacking other more lightly bonded molecules, possibly at humidities above 38% and the optimized 90 volt setting. Thus, there was not enough energy left after attacking all water molecules to decompose an appreciable amount of $N_2$. If nitrogen breakdown does not occur, then oxides of nitrogen are not likely to be produced.ced.

  • PDF

Two-Way Coupled Fluid Structure Interaction Simulation of a Propeller Turbine

  • Schmucker, Hannes;Flemming, Felix;Coulson, Stuart
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.342-351
    • /
    • 2010
  • During the operation of a hydro turbine the fluid mechanical pressure loading on the turbine blades provides the driving torque on the turbine shaft. This fluid loading results in a structural load on the component which in turn causes the turbine blade to deflect. Classically, these mechanical stresses and deflections are calculated by means of finite element analysis (FEA) which applies the pressure distribution on the blade surface calculated by computational fluid dynamics (CFD) as a major boundary condition. Such an approach can be seen as a one-way coupled simulation of the fluid structure interaction (FSI) problem. In this analysis the reverse influence of the deformation on the fluid is generally neglected. Especially in axial machines the blade deformation can result in a significant impact on the turbine performance. The present paper analyzes this influence by means of fully two-way coupled FSI simulations of a propeller turbine utilizing two different approaches. The configuration has been simulated by coupling the two commercial solvers ANSYS CFX for the fluid mechanical simulation with ANSYS Classic for the structure mechanical simulation. A detailed comparison of the results for various blade stiffness by means of changing Young's Modulus are presented. The influence of the blade deformation on the runner discharge and performance will be discussed and shows for the configuration investigated no significant influence under normal structural conditions. This study also highlights that a two-way coupled fluid structure interaction simulation of a real engineering configuration is still a challenging task for today's commercially available simulation tools.

Chloride and lactate as prognostic indicators of calf diarrhea from eighty-nine cases

  • Gencay Ekinci;Emre Tufekci;Youssouf Cisse;Ilknur Karaca Bekdik;Ali Cesur Onmaz;Oznur Aslan;Vehbi Gunes;Mehmet Citil;Ihsan Keles
    • Journal of Veterinary Science
    • /
    • v.25 no.3
    • /
    • pp.38.1-38.16
    • /
    • 2024
  • Importance: Deaths due to neonatal calf diarrhea are still one of the most critical problems of cattle breeding worldwide. Determining the parameters that can predict diarrhea-related deaths in calves is especially important in terms of prognosis and treatment strategies for the disease. Objective: The primary purpose of this study was to determine mortality rates and durations, survival status, and predictive prognosis parameters based on vital signs, hematology, and blood gas analyses in neonatal diarrheic calves. Methods: The hospital automation system retrospectively obtained data from 89 neonatal diarrheic calves. Results: It was found that 42.7% (38/89) of the calves brought with the complaint of diarrhea died during hospitalization or after discharge. Short-term and long-term fatalities were a median of 9.25 hours and a median of 51.50 hours, respectively. When the data obtained from this study is evaluated, body temperature (℃), pH, base excess (mmol/L), and sodium bicarbonate (mmol/L) parameters were found to be lower, and hemoglobin (g/dL), hematocrit (%), lactate (mmol/L), chloride (mmol/L), sodium (mmol/L) and anion gap (mmol/L) parameters were found to be higher in dead calves compared to survivors. Accordingly, hypothermia, metabolic acidosis, and dehydration findings were seen as clinical conditions that should be considered. Logistic regression analysis showed that lactate (odds ratio, 1.429) and CI- (odds ratio, 1.232) concentration were significant risk factors associated with death in calves with diarrhea. Conclusions and Relevance: According to the findings obtained from this study, the determination of lactate and Cl- levels can be used as an adjunctive supplementary test in distinguishing calves with diarrhea with a good prognosis.