• Title/Summary/Keyword: Discharge Properties

Search Result 1,318, Processing Time 0.03 seconds

A study for High Efficiency Dewatering of Sludge Contained Fine Particles (미세입자(微細粒子)를 함유(含有)한 슬러지의 고효율(高效率) 탈수(脫水) 연구)

  • Lee, Jung-Eun;Lee, Jae-Keun
    • Resources Recycling
    • /
    • v.15 no.4 s.72
    • /
    • pp.36-43
    • /
    • 2006
  • There was some difficulty dewatering properties due to small porosity diameter of cake, when pigment sludge contained fine particle was formed by cake under the dewatering. It was difficult to dewater the sludge with fine particles with the conventional mechanical dewatering method. This study was to improve the dewatering rate as discharging the water from porosity of cake easily, supplying the low heat to the cake layer. Thermal dewatering equipment of piston type to keep up constant temperature on the cake was set up and relative experiment was conducted for sludge of 200 g with fine pigment particle. As test results. filtration of 176.8 g, cake weight of 19.4 g, cake thickness of 4.2 mm was measured, and it was analyzed that the water content of cake was 47 wt% and dewatering velocity, which moaned the residual d교 sloid amount per dewatering area, was $2.1DS\;m^{2}{\cdot}cycle$. This results showed that filtration increased, cake weight and thickness decreased and dewatering velocity increased against mechanical dewatering method. And water content of cake decreased about 30%, so the result which dewatering rate improved was drew generally. The reason is that the inner vapor pressure working at the cake porosity increased as applying the low heat to the cake layer, which lead to discharge the water from porosity easily. Therefore, this study was estimated by the useful technology for sludge reduction.

Clincal Effect of Ketotifen in Allergic Rhinitis (알레르기성 비염에 대한 Ketotifen($Zaditen^{(R)}$)의 임상적 효과)

  • Eun, Sun-Jin;Kim, Yang-Dae;Park, Mun-Heum;Suh, Jang-Su;Song, Kei-Won
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.105-112
    • /
    • 1990
  • Ketotifen, a benzocycloheptathiophene, has an orally effective antiallergic as well as antihistaminic properties. In pervious studies, Ketotifen has shown encouraging results in patient with allergic rhinitis, either perennial or seasonal. 39 patients with allergic rhinitis had been treated with Ketotifen 1 mg twice daily for 8 weeks. And we obtained following results. 1) The efficacy rate in sneezing attack was 73.5%, in nasal discharge 71%, in nasal obstruction 58%. 2) Some improvements in at least one of three major symptoms were noted within 1 week in 30.7%, within 2 weeks in 55.8%, within 3 weeks in 66.7%, within 8 weeks in 87.2%. 3) Physical findings such as colour, swelling of turbinate, character of rhinorrhea were not improved significantly. 4) Side effect was observed only in one patient with abdominal pain and diarrhea, which was subsided after interruption of administration. These results suggested that Ketotifen was effective in treatment of allergic rhinitis.

  • PDF

Synthesis and Characterization of IPA-co-HDO-co-(TPA/MA) Anion-Exchange Membrane for All-Vanadium Redox Flow Battery (전바나듐계 레독스-흐름 전지용 IPA-co-HDO-co-(TPA/MA) 음이온교환막의 합성 및 특성)

  • Jung, Jae-Chul;Kwak, Noh-Seok;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.593-598
    • /
    • 2011
  • The IPA-co-HDO-co-(TPA/MA) copolymers for all-vanadium redox flow battery were synthesized by melt condensation polymerization using isophthalic acid(IPA), 1,6-hexandiol (HDO), terephthalic acid(TPA) and maleic anhydride(MA). The amination of chloromethylated IPA-co- HDO-co-(TPA/MA)(CIHTM) copolymer was carried out using trimethylamine, and the anion exchange membrane was also prepared by UV crosslinking reaction. The structure and thermal stability of IHTM copolymers were confirmed by FTIR, $^1H$ NMR, and TGA analysis. The anion membrane properties such as water uptake, ion exchange capacity, electric resistance and electrical conductivity, were measured by gravimetry, titration and LCR meter. The efficiency of the all-vanadium redox flow battery was analyzed. The ion exchange capacity, electric resistance and electrical conductivity were 1.10 meq/g, $1.98{\Omega}{\cdot}cm^2$, and 0.009 S/cm, respectively. The efficiency of charge-discharge, voltage, and energy for the allvanadium redox flow battery were 96.5, 74.6, 70.0%, respectively.

Electrochemical Properties of Boron-doped Cathode Materials (LiNi0.90Co0.05Ti0.05O2) for Lithium-ion Batteries (붕소가 도핑된 리튬이온전지용 양극 활물질(LiNi0.90Co0.05Ti0.05O2)의 전기화학적 특성)

  • Kim, Geun Joong;Park, Hyun Woo;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.832-840
    • /
    • 2019
  • To improve the electrochemical performances of the cathode materials, boron-doped $LiNi_{0.90}Co_{0.05}Ti_{0.05}O_2$ were synthesized by using concentration gradient precursor. The characteristics of the prepared cathode materials were analyzed by XRD, SEM, EDS, PSA, ICP-OES and electrical conductivity measurement. The electrochemical performances were investigated by initial charge/discharge capacity, cycle stability, C-rate, cyclic voltammetry and electrochemical impedance spectroscopy. The cathode material with 0.5 mol% boron exhibited a capacity of 187 mAh/g (0.5 C) in a voltage range of 2.7~4.3 V(vs. $Li/Li^+$), and an capacity retention of 94.7% after 50 cycles. In the relatively high voltage range of 2.7~4.5 V(vs. $Li/Li^+$), it showed a high capacity of 200 mAh/g and capacity retention of 80.5% after 50 cycles.

Electrochemical performance of the flexible supercapacitor based on nanocarbon material/conductive polymer composite and all solid state electrolyte (탄소나노복합재료와 전고체 전해질 기반의 유연성 슈퍼커패시터의 전기화학적 특성 분석)

  • Kim, Chang Hyun;Kim, Yong Ryeol;Jeong, Hyeon Taek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.200-207
    • /
    • 2019
  • In this study, flexible supercapacitor based on the all solid state electrolyte with PVA (polyvinyl alcohol)-$H_3PO_4$, ionic liquid as a BMIMBF4 (1-buthyl-3-methylimidazolium tetrafluoroborate) and reduced graphene oxide/conductive polymer composite was fabricated and characterized electrochemical properties with function of its flexibility. In order to measure and compare that electrochemical performances (including cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS) and galvanostatic charge/discharge,after 0~100th bending test) of prepared flexible supercapacitor based on reduced graphene oxide/conducting polymer composite and all solid state electrolyte, we have conducted press machine with constant pressure ( 0.01/cm2) for $100^{th}$ bending test. As a result, specific capacitance of the flexible supercapacitor was 43.9 F/g which value decreased to 42.0 and 40.1 F/g after 50 and $100^{th}$ bending test, respectively. This result exhibited that decreased electrochemical property of the flexible supercapacitor effected on physical stress on the electrode after repeated bending test. In addition, we have measured that electrode surface morphology by SEM to prove its decreased electrochemical property of the flexible supercapacitor after prolonged bending test.

Improving the Port-Reception-Facility System (선박 배출 오염물질 항만처리시스템 확보방안 연구)

  • Ha, Shin-Young;Gug, Seung-Gi
    • Journal of Navigation and Port Research
    • /
    • v.44 no.6
    • /
    • pp.488-493
    • /
    • 2020
  • In this study, we sought to establish a vessel-discharge pollutant-treatment system recommended by IMO by first investigating advanced facilities overseas to help us understand and evaluate our domestic facility and needs. IMO recommends the installation and operation of port pollutant-storage facilities to adequately treat pollutants emitted by ships entering the port, and we reviewed the registration and operation of these facilities in IMO member countries, focusing on the IIII Code. Due to recent environmental regulations, additional facilities are required to treat the washing water discharged from equipment such as scrubbers mounted on the ship so pollutant-storage facilities must be established. Currently, Korea's ship-discharged wastes are being moved from ports to land waste-treatment plants, and their quantity and properties are not being monitored. Therefore, in this study, we improved monitoring of the discharged pollutants and investigated the proper arrangement of pollutant storage facilities as recommended by IMO. The system we established can help provide smooth service to incoming ships - and appropriate treatment of pollutants and will greatly benefit international maritime operations.

The Engineering Characteristics of the Sludge Mixed Soil (슬러지 혼합토의 공학적 특성)

  • Kim, JungUn;Kim, MyeongKyun;Bae, WooSeok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.5
    • /
    • pp.43-50
    • /
    • 2011
  • As a result of population growth and economic growth, household and industrial wastes continue to rapidly increase every year. Especially, sewage sludge produced at final stage is increasing with the constant construction and putting in good order of the sewage plant. In addition to the government's prohibition for filling up the sludge, it became more and more difficult to discharge wastes to the sea as London Dumping Convention '96 came into effect. And sewage sludge and the livestock wastes are expected to be thoroughly prohibited from discharging to the sea from 2012. So we need desperately economical and useful alternatives to compact and reuse these wastes. The purpose of this study is to evaluate the utilization of solidified sludge-soil mixture as an enhancement and covering material. To determine the proper mixed ratio of solidified sludge, this study conducted basic physical properties tests, compaction tests, uniaxial compression tests, and permeability test. It was found that the higher the ratio of solidified sludge, the lower the coefficient of permeability. Upon the results of particle size distribution, the mixed ratio of solidified sludge that meet the enhancement material condition was 59% or lower for SP granite soil and 48% or lower for SM granite soil respectively.

Preparation and Characterization of a Cross-Linked Anion-Exchange Membrane Based on PVC for Electrochemical Capacitor (전기화학 캐퍼시터용 PVC기반 가교 음이온교환 멤브레인의 제조 및 특성)

  • Kim, Young-Ji;Kim, Soo-Yeoun;Choi, Seong-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.903-913
    • /
    • 2021
  • Three-type PVC membranes denoted by AEM-1, AEM-2, and AEM-3 with a cross-linked anion-exchange group were prepared by substitution reaction of PVC with triethyldiamine (TEDA), 1,4-dimethylpiperazine (DMP), and 1,4-bis(imidazol-1-ylmethyl)benzene (BIB) in cyclohexanone, respectively. We confirmed the successful preparation of the AEM-1, AEM-2, and AEM-3 via ionic conductivity (S/cm), water uptake (%), contact angle, ion-exchange capacity (meq/g), thermal properties, SEM and XPS analysis, respectively. The electrochemical capacitor experiments using PVC membrane with cross-linked anion-exchange group in organic electrolytes were performed. The prepared AEM-1, AEM-2 AEM-3 have a good stability by charge and discharge performance in organic electrolyte. As a result, the AEM-2 and AEM-3 membrane based on PVC prepared by the solvent casting method after substituent reaction is suitable for the use as a separator in organic electrochemical capacitor (supercapacitor).

A Study on the Electrochemical Performance of Fe-V Chloric/Sulfuric Mixed Acid Redox Flow Battery Depending on Electrode Activation Temperature (Fe-V Chloric/Sulfuric Mixed Acid 레독스흐름전지 전극의 활성화 온도에 따른 전기화학적 성능 고찰)

  • Lee, Han Eol;Kim, Dae Eop;Kim, Cheol Joong;Kim, Taekeun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.639-645
    • /
    • 2020
  • Among the components of redox flow battery (RFB), the electrode serves as a diffusion layer of an electrolyte and a path for electrons and also is a major component that directly affects the RFB performance. In this paper, chloric/sulfuric mixed acidwas used as a supporting electrolyte in RFB system with Fe2+/Fe3+ and V2+/V3+ as redox couple. The optimum electrode and activation temperature were suggested by comparing the capacity, coulombic efficiency and energy efficiency according to the electrode type and activation temperature. In the RFB single cell evaluation using 5 types of carbon electrodes used in the experiments, all of them showed close to the theoretical capacity to retain the reliability of the evaluation results. GFD4EA showed relatively excellent energy efficiency and charge/discharge capacity. In order to investigate the electrochemical performance according to the activation temperature, GFD4EA electrode was activated by heat treatment at different temperatures of 400, 450, 500, 600 and 700 ℃ under an air atmosphere. Changes in physical properties before and after the activation were observed using electrode mass retention, scanning electron microscope (SEM), XPS analysis, and electrochemical performance was compared by conducting RFB single evaluation using electrodes activated at each temperature given above.

Evaluation of Compressive Strength and Freeze-thaw Resistance Properties of Concrete using Superabsorbent Polymer (고 흡수성 폴리머를 혼입한 콘크리트의 압축 강도 및 동결융해 저항성 평가)

  • Kim, Il-Sun;Choi, So-Yeong;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.86-94
    • /
    • 2020
  • When the Superabsorbent Polymer (SAP) is added into concrete, the slump decreases rapidly, deteriorating the workability, the internal curing effect can be obtained through the water absorption and discharge process, and the internal voids of the concrete are increased. In this study, the effects of internal curing and voids were evaluated by evaluating the compressive strength, freeze-thaw resistance, and chloride penetration resistance of SAP-adding concrete that secured workability using a water reducing agent. Also, the internal curing effect of SAP was evaluated by dividing the curing conditions of concrete into water curing and sealed curing. From the result, as the SAP adding ratio increased, the amount of water reducing agent increased, and as for the compressive strength, the SAP adding ratio of 1.5% showed the greatest compressive strength. In particular, in the case of sealed curing showed higher compressive strength than the water curing. It is considered that the compressive strength increased due to the reduction of the effective water-cement ratio and the internal curing effect. Adding 1.0~1.5% of SAP improved the freeze-thaw resistance similar to the case of adding the AE agent, and the addition of more than 1.0% of SAP improved the chloride penetration resistance. The optimal adding ratio of SAP is 1.5%, and the adding ratio of 2.0% or more adversely affects the compressive strength and freeze-thaw resistance.