• Title/Summary/Keyword: Discharge Pressure

Search Result 1,480, Processing Time 0.029 seconds

A study on the machine load on shield advancing between soil ground and mix ground included core stone (토사지반과 핵석이 포함된 복합지반에서 쉴드TBM 굴진 시 장비부하에 관한 연구)

  • Kim, Ki-Hwan;Kim, Hyouk;Mun, Cheol-Hwa;Kim, Young-Hyu;Kim, Dong-Ho;Lee, Jae-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1039-1048
    • /
    • 2018
  • In urban tunnel construction, most of the Shield TBM method is applied to secure the safety of buildings and to minimize risks. On the other hand, in the urban development process, landfills are often embanked or improving in many cases, so that the boundary between the surface and the rock is often heterogeneous. In case of ground condition such as alluvial soil, granite, decomposed granite, core stone and rock with various layers, datas on shield TBM advancing according to each ground condition are analyzed, The characteristics of machine load were compared and analyzed. As a result, it can be predicted that the change of ground condition can be predicted by the tendency of discharge volume, thrust force and cutting wheel torque when the cutter is checked and replaced regularly on advancing under maintaining the design slurry pressure.

Effect of cold plasma treatment on the quantitative compositions of silkworm powder

  • Jo, You-Young;Seo, YoungWook;Lee, Young Bo;Kim, Seong-Ryul;Kweon, HaeYong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.38 no.2
    • /
    • pp.25-30
    • /
    • 2019
  • Atmospheric-pressure plasma technique is a technology for sterilizing agricultural product. In this study, dielectric barrier discharge plasma was applied to silkworm powder for 1 to 5 h with less than 2 ppm of $O_3$ and $NO_2$. Quantitative compositions including proximate contents, mineral and heavy metal contents, fatty acids, vitamins, and DNJ contents were measured. Proximate contents of silkworm powder were protein (57.2%), fat (9.9%), fiber (4.6%), ash (10.1%), and moisture (5.7%). These compositions were not affected by the treatment of plasma. Silkworm powder has 5 abundant minerals potassium (K), phosphorus (P), sulfur (S), calcium (Ca), and magnesium (Mg). Among these minerals, plasma treatment decreased the contents of P and S sharply from 732.3 to 176.8, and 492.7 to 185.2 mg/100g, respectively. Heavy metal contents including lead (Pb), cadmium (Cd), arsenic (As), and mercury (Hg) were not detected in the silkworm powder. Five vitamins such as ascorbic acid (13.6 mg/100g), riboflavin (5.4 mg/100g), ${\beta}$-carotene (1.8 mg/100g), niacin (0.6 mg/100g), and thiamine (0.4 mg/100g) were not significantly changed by plasma treatment. Silkworm powder is composed of 30 parts saturated fatty acids and 70 parts unsaturated ones. The fatty acid composition was not significantly changed by plasma treatment. The DNJ content of silkworm powder (3.72 mg/g) was also nearly constant within the experimental condition of plasma treatment.

Evaluation of Nonthermal Plasma Treatment by Measurement of Stored Citrus Properties

  • Seo, Youngwook;Park, Jong-Ryul;Park, Hoe Man
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.401-409
    • /
    • 2018
  • Decay of fruit is one of the greatest issues in fruit storage. Purpose: In this study, citrus sterilization was performed to evaluate a dry sterilization method using an atmospheric-pressure nonthermal plasma treatment based on a dielectric-barrier discharge technique. Methods: Citrus samples were stored under four different environmental conditions as follows: group A had cold storage with plasma treatment with a temperature of $6.2{\pm}1.0^{\circ}C$ and relative humidity (RH) of $93.4{\pm}8.2%$, group B had ambient-temperature storage with $22.9{\pm}2.3^{\circ}C$ and $82.1{\pm}4.5%$ RH, group C ambient-temperature storage with plasma treatment with $25.3{\pm}2.2^{\circ}C$ and $90.0{\pm}2.8%$ RH, and group D had cold storage with $5.7{\pm}1.0^{\circ}C$ and $93.4{\pm}6.5%$ RH. Results: As a result of citrus surface sterilization by plasma treatment, treatment groups A and C together showed an average of 16.1 CFU/mL of mold colonies, while control groups B and D showed an average of $2.2{\times}10^2CFU/mL$ or approximately 13 times greater than the treatment groups. Regarding the mean concentration of aerobic bacteria colonies, the treatment groups (A and C) and control groups (B and D) showed an average of 7.1 CFU/mL and $1.9{\times}10^3CFU/mL$, respectively. This is approximately a 270-fold difference in the concentration of pathogen colonies between treatment and control groups. Conclusions: The results showed the potential of nonthermal plasma treatment for citrus storage in enhancing storage duration and quality preservation.

Numerical Analysis on the Cavitation Performance of a Seawater Cooling Pump (해수냉각 펌프의 캐비테이션 성능에 대한 수치해석)

  • Tran, Bao Ngoc;Kim, Jun-ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • In this study, a centrifugal seawater cooling pump was analyzed to investigate its cavitation behavior over different operating flow rates. 3D two-phase simulations were carried out with ANSYS-CFX commercial code. The $k-{\varepsilon}$ turbulence and Rayleigh-Plesset cavitation models were employed in the simulations. A head drop characteristics curves for three discharge rates was built based on numerical predictions. At higher flow rates, the impeller was more vulnerable to bubble cavitation. The 3 % head drop points of the pump working at 0.7Q, Q, and 1.3Q (Q: design flow rate) corresponded with NPSHa 1.21 m, 1.83 m, and 3.45 m, respectively. The volume of vapor bubbles was estimated and cavitation locations were anticipated to visualize the development of the cavity within the impeller. Moreover, the distribution of pressure coefficient and a blade loading chart are specifically presented, bringing out the harmful impacts of cavitation on the pump operation.

A Facile Process for Surface Modification with Lithium Ion Conducting Material of Li2TiF6 for LiMn2O4 in Lithium Ion Batteries

  • Kim, Min-Kun;Kim, Jin;Yu, Seung-Ho;Mun, Junyoung;Sung, Yung-Eun
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.223-230
    • /
    • 2019
  • A facile method for surface coating with $Li_2TiF_6$ which has a high lithium-ion conductivity, on $LiMn_2O_4$ spinel cathode material for high performance lithium ion batteries. The surface coating is performed by using a co-precipitation method with $Li_2CO_3$ powder and $H_2TiF_6$ solution under room temperature and atmospheric pressure without special equipment. Total coating amount of $Li_2TiF_6$ is carefully controlled from 0 to 10 wt.% based on the active material of $LiMn_2O_4$. They are evaluated by a systematic combination of analyses comprising with XRD, SEM, TEM and ICP. It is found that the surface modification of $Li_2TiF_6$ is very beneficial to high cycle life and excellent rate capability by reducing surface failure and supporting lithium ions transportation on the surface. The best coating condition is found to have a high cycle life of $103mAh\;g^{-1}$ at the 100th cycle and a rate capability of $102.9mAh\;g^{-1}$ under 20 C. The detail electrochemical behaviors are investigated by AC impedance and galvanostatic charge and discharge test.

The Effect of Korean Medical Complex Treatment on Functional Dyspepsia Patients : Through Measurement of Functional Dyspepsia Symptoms through NDI-K (Nepean Dyspepsia Index-Korean Version), Pressure Pain Threshold through an Algometer (기능성 소화불량 환자에 대한 한의복합치료 효과 : NDI-K(Nepean Dyspepsia Index-Korean version)를 통한 기능성 소화불량증상, algometer를 통한 압력통각역치 측정을 통하여)

  • Rho, Gi-Hwan;Choi, Gyu-Ho;Lee, Sang-Hyun;Choi, Seo-Hyung;Noh, Hyeon-Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.100-104
    • /
    • 2022
  • The purpose of this study is to observe the effectiveness of the Korean medical complex treatments for functional dyspepsia (FD). And we observed NDI-K (Nepean dyspepsia index-Korean version) and algometer on acupoints to confirm the treatment effectiveness. In this retrospective study, we investigated 77 patients with FD symptoms who admitted to 00 Korean Hospital for 2 weeks from April 14, 2020 to March 31, 2021. All patietns were treated with herbal medicines, acupuncture, pharmacopuncture, moxa treatment, aroma therapy, So-jeok and So-jeok II therapy. On the day of admission and discharge, NDI-K, algometer on acupoints (CV12, CV10, ST25, ST27, SP14) were examined twice. Among the NDI-K values, all 14 items except for poor breathing were decreased statistically significantly. The algometer values were increased statistically significantly in all acupoints (CV12, CV10, ST25, ST27, SP14). These results suggest that Korean medical treatment can be useful in the treatment of FD.

Implementation of Human Positioning Monitoring Device for Underwater Safety (수중안전을 위한 인체 위치추적 모니터링 장치 구현)

  • Jong-Hwa Yoon;Dal-Hwan Yoon
    • Journal of IKEEE
    • /
    • v.27 no.3
    • /
    • pp.225-233
    • /
    • 2023
  • This paper implements a system that monitors human body lifting information in the event of a marine accident. The monitoring system performs ultrasonic communication through a lifting device controller that transmits underwater environment information, and LoRa communication is performed on the water to provide GPS information within 10 km to the control center or mother ship. The underwater lifting controller transmits pneumatic sensor, gyro sensor, and temperature sensor information. In an environment where the underwater conditions increase by one atmosphere of water pressure every 10m in depth, and the amount of air in the instrument decreases by half compared to land, a model of a 60kg underwater mannequin is used. Using one 38g CO2 cartridge in the lifting appliance SMB(Surface Maker Buoy), carry out a lifting appliance discharge test based on the water level rise conditions within 10 sec. Underwater communication constitutes a data transmission environment using a 2,400-bps ultrasonic sensor from a depth of 40m to 100m. The monitoring signal aims to ensure the safety and safe human structure of the salvage worker by providing water depth, water temperature, and directional angle to rescue workers on the surface of the water.

Performance evaluation of rotating roller type raw anchovy sorting machine (회전롤러식 생멸치 선별기계 성능평가)

  • Ok-sam KIM;Seok-bong JEONG;Doo-jin HWANG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.28-34
    • /
    • 2023
  • In the anchovy boat seine fishing boat, it is necessary to select other aquatic organisms other than live anchovies, which are the target species of catch. By making a rotating roller sorter using hydraulic pressure, the anchovy sorting amount was compared and the sorting accuracy of the rotary roller sorter, and the discharge speed of butter fish and jerry fish according to the number of roller revolutions were analyzed. The rotating roller sorter increases the weight of the sorted raw anchovy by 54%, 74% and 91.5% compared to the round bar fixed type, so it can reduce the required time by an average of 73.2%. As a result of converting the sorting accuracy to the weight of pure anchovies excluding the catch weight, the round bar fixed type was 89%; however, the average of the rotating roller sorter was 97.7%. Thus, the sorting accuracy of the rotary roller sorter was further improved by about 8.7%. The roller speed moved 7% at 300 rpm, 7.5% at 600 rpm, and 16% at 900 rpm, so butter fish were discharged overboard 10% faster than jelly fish on average. In addition, the average feed speed of butter fish and jelly fish is 1,400 mm/s when the roller rotation speed is 300 rpm, 1,480 mm/s at 600 rpm, and 1,850 mm/s at 900 rpm. A Φ58 mm roller rotates once it moved about 1.23 mm. In the future, a follow-up study of quantitative evaluation is needed targeting more non-target fish species of anchovy boat seine.

Influencing factors for Sleep Disturbance in the Intensive Care Unit Patients: A Systematic Review (중환자실 환자의 수면에 영향을 미치는 요인: 체계적 고찰)

  • Cho, Young Shin;Joung, Sunae
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.2
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : Sleep disturbances in patients in the intensive care unit (ICU) are related to health problems after discharge. Therefore, active prevention and management are required. Hence, identification of the factors that affect sleep in patients who are critically ill is necessary. Methods : The PubMed, Cochrane Library, CINAHL, EMBASE, and Web of Science databases were searched. Selection criteria were observational and experimental studies that assessed sleep as an outcome, included adult patients admitted to the ICU, and published between November 2015 and April 2022. Results : A total of 21,136 articles were identified through search engines and manual searches, and 42 articles were selected. From these, 22 influencing factors and 11 interventions were identified. Individual factors included disease severity, age, pain, delirium, comorbidities, alcohol consumption, sex, sleep disturbance before hospitalization, chronic obstructive pulmonary disease (COPD), cardiovascular disease, and high diastolic blood pressure (DBP), low hemoglobin (Hb), and low respiratory rate (RR). Environmental factors included light level, noise level, and temperature. Furthermore, treatment-related factors included use of sedatives, melatonin administration, sleep management guidelines, ventilator application, nursing treatment, and length of ICU stay. Regarding sleep interventions, massage, eye mask and earplugs, quiet time and multicomponent protocols, aromatherapy, acupressure, sounds of the sea, adaptive intervention, circulation lighting, and single occupation in a room were identified. Conclusion : Based on these results, we propose the development and application of various interventions to improve sleep quality in patients who are critically ill.

Association between Optic Nerve Sheath Diameter/Eyeball Transverse Diameter Ratio and Neurological Outcomes in Patients with Aneurysmal Subarachnoid Hemorrhage

  • Jinsung Kim;Hyungoo Shin;Heekyung Lee
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.6
    • /
    • pp.664-671
    • /
    • 2023
  • Objective : The optic nerve sheath diameter (ONSD)/eyeball transverse diameter (ETD) ratio is a more reliable marker of intracranial pressure than the ONSD alone. We aimed to investigate the predictive value of the ONSD/ETD ratio (OER) for neurological outcomes in patients with aneurysmal subarachnoid hemorrhage (aSAH). Methods : Adult patients with aSAH who visited the emergency department of a tertiary hospital connected to a South Korean university between January 2015 and December 2021 were included. Data on patient characteristics and brain computed tomography scan findings, including the ONSD and ETD, were collected using a predefined protocol. According to the neurological outcome at hospital discharge, the patients were divided into the unfavorable neurological outcome (UNO; cerebral performance category [CPC] score 3-5) and the favorable neurological outcome (FNO; CPC score 1-2) groups. The primary outcome was the association between the OER and neurological outcomes in patients with aSAH. Results : A total of 171 patients were included in the study, of whom 118 patients (69%) had UNO. Neither the ONSD (p=0.075) nor ETD (p=0.403) showed significant differences between the two groups. However, the OER was significantly higher in the UNO group in the univariate analysis (p=0.045). The area under the receiver operating characteristic curve of the OER for predicting UNO was 0.603 (p=0.031). There was no independent relationship between the OER and UNO in the multivariate logistic regression analysis (adjusted odds ratio, 0.010; p=0.576). Conclusion : The OER was significantly higher in patients with UNO than in those with FNO, and the OER was more reliable than the ONSD alone. However, the OER had limited utility in predicting UNO in patients with aSAH.