• 제목/요약/키워드: Discharge Input Power

검색결과 158건 처리시간 0.025초

PDP를 위한 새로운 전류원 타입의 에너지 회수 및 방전유지 회로 (A Novel Current-fed Energy Recovery Sustaining Driver for Plasma Display Panel (PDP))

  • 한상규;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.755-760
    • /
    • 2003
  • A novel current-fed energy-recovery sustaining driver (CFERSD) for a PDP is proposed in this paper. Its main idea is to recover the energy stored in the PDP or to inject the input source energy to the PDP by using the current source built-up in the energy recovery inductor. This method provides zero-voltage-switching (ZVS) of all main power switches, the reduction of EMI, and more improved operational voltage margins with the aid of the discharge current compensation. In addition, since the current flowing through the energy recovery inductor can compensate the plasma discharge current flowing through the conducting power switches, the current stress through all main power switches can be considerably reduced. Furthermore, it features a low conduction loss and fast transient time. Operations, features and design considerations are presented and verified experimentally on a 1020X106mm sized PDP, 50kHz-switching frequency, and sustaining voltage 140V based prototype.

  • PDF

Plasma 부하를 갖는 System에서의 Automatching 회로

  • 황기웅;김원규;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1985년도 하계학술회의논문집
    • /
    • pp.224-227
    • /
    • 1985
  • During operation of an RF glow discharge system, it can be observed that the reflected power tends to increase in small value, due to changes in the impedance of the system. This problem can be relieved by adding an automatic impedance matching circuit to the system. This paper presents a detailed method of automatically matching the input impedance of a 50 ohm transmission line to an RF glow discharge system at 13.56 MHZ.

  • PDF

Comparison of Classification Rate for PD Sources using Different Classification Schemes

  • Park Seong-Hee;Lim Kee-Joe;Kang Seong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.257-262
    • /
    • 2006
  • Insulation failure in an electrical utility depends on the continuous stress imposed upon it. Monitoring of the insulation condition is a significant issue for safe operation of the electrical power system. In this paper, comparison of recognition rate variable classification scheme of PD (partial discharge) sources that occur within an electrical utility are studied. To acquire PD data, five defective models are made, that is, air discharge, void discharge and three types of treeinging discharge. Furthermore, these statistical distributions are applied to classify PD sources as the input data for the classification tools. ANFIS shows the highest rate, the value of which is 99% and PCA-LDA and ANFIS are superior to BP in regards to other matters.

부극성 직류 코로나 방전에 미치는 자계의 영향 (Effect of Magnetic Field on Negative DC Corona Discharge)

  • 박재윤;김익균;정장근;김건호;김정달;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2308-2310
    • /
    • 1999
  • The effect of magnetic field on NOx removal characteristics from a combustion flue gas has been experimentally investigated for a DC corona discharge reactor with a multipoint plate geometry in our Lab. Combustion flue gas removal efficiency of this type was much higher than that of the other types. In this paper, needle-plate geometry discharge system with applied magnetic field at a right angle to the electric field was made. Input power source was used negative DC. The corona discharge characteristics for this system was investigated and compared with the corona characteristics for the corona discharge system without magnetic field.

  • PDF

Flow Actuation by DC Surface Discharge Plasma Actuator in Different Discharge Modes

  • Kim, Yeon-Sung;Shin, Jichul
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권3호
    • /
    • pp.339-346
    • /
    • 2015
  • Aerodynamic flow control phenomena were investigated with a low-current DC surface discharge plasma actuator. The plasma actuator was found to operate in three different discharge modes with similar discharge currents of about 1 mA or less. Stable continuous DC discharge without audible noise was obtained at higher ballast resistances and lower discharge currents. However, even with continuous DC power input, a low-frequency self-pulsed discharge was obtained at lower ballast resistances, and a high-frequency self-pulsed discharge was obtained at higher set-point currents and higher ballast resistances, both with audible noise. The Schlieren image reveals that the low-frequency self-pulsed mode produces a synthetic jet-like flow implying that a gas heating effect plays a role, even though the discharge current is small. The high-frequency self-pulsed mode produces pulsed jets in a tangent direction, and the continuous DC mode produces a steady straight pressure wave. Particle image velocimetry (PIV) images reveal that the induced flow field by the low-frequency self-pulsed mode has flow propagating in the radial direction and centered between the electrodes. The high-frequency self-pulsed mode and continuous DC mode produce flow from the anode to the cathode. The perturbed region downstream of the cathode is larger in the high-frequency self-pulsed mode with similar maximum speeds.

Modeling and Analysis of an Avionic Battery Discharge Regulator

  • Chen, Qian;Yu, Haihong;Huang, Xiaoming;Lu, Yi;Qiu, Peng;Tong, Kai;Xuan, Jiazhuo;Xu, Feng;Xuan, Xiaohua;Huang, Weibo;Zhang, Yajing
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1218-1225
    • /
    • 2016
  • The avionic battery discharge regulator (BDR) plays an important role in a power-conditioning unit. With its merits of high efficiency, stable transfer function, and continuous input and output currents, the non-isolated Weinberg converter (NIWC) is suitable for avionic BDR. An improved peak current control strategy is proposed to achieve high current-sharing accuracy. Current and voltage regulators are designed based on a small signal model of a three-module NIWC system. The system with the designed regulators operates stably under any condition and achieves excellent transient response and current-sharing accuracy.

Symmetric Adiabatic Logic Circuits against Differential Power Analysis

  • Choi, Byong-Deok;Kim, Kyung-Eun;Chung, Ki-Seok;Kim, Dong-Kyue
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.166-168
    • /
    • 2010
  • We investigate the possibility of using adiabatic logic as a countermeasure against differential power analysis (DPA) style attacks to make use of its energy efficiency. Like other dual-rail logics, adiabatic logic exhibits a current dependence on input data, which makes the system vulnerable to DPA. To resolve this issue, we propose a symmetric adiabatic logic in which the discharge paths are symmetric for data-independent parasitic capacitance, and the charges are shared between the output nodes and between the internal nodes, respectively, to prevent the circuit from depending on the previous input data.

고주파 유도방전 플라즈마 특성에 관한 연구 (A Study on the Characteristics of the Radio-Frequency Induction Discharge Plasma)

  • 박원주
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.34-39
    • /
    • 1999
  • 본 연구에서는 랑그뮤어 푸로브법을 이용요하여 고주파 유도결합 플라즈마에서 전자온도와 전자밀도를 측정하였다. 실험의 공통조건은 압력 10∼40[mTorr], 입력파워는 100∼600[W]이고, 공간분포는 측정에서의 아스펙트비(R/L)는 2로하였다. 전자온도와 전자밀도의 의존성을 측정한 결과 입력파워에서는 전자온도는 약간 증가하는 경향을 보이고 있지만 전자말도는 입력파워가 100∼250[W]까지는 증가율이 완만하고 450[W]에서 포화하는 것을 알수 있었다. 압력에 대한 의존성은 압력이 낮을수록 높은 값을 나타내고 전자밀도에서는 압력이 증가함에 따라 증가하는 것을 알 수 있었다. 전자온도의 반경방향의 공간분포는 석영창 부근에서 기판쪽으로 갈수록 감소되는 경향이 있다. 전자밀도에서는 플라즈마 중심부에서 석영창 쪽으로 약간 이동한 위치에서 피크의 값을 가지고, 석영창과 기판쪽에서는 그 값이 감소함을 볼 수 있었다. 전자온도의 축방향의 공간분포는 석영창 부근에서 기판쪽으로 감소되는 경향이 있다. 또, 전자밀도는 플라즈마 중심부에서 석영창 쪽으로 약간 이동한 위치에서 피크의 값을 가지고, 석영창과 기판쪽에서는 그 값이 감소함을 볼 수 있었다. 이상의 결과들은 유도방전플라즈마의 메카니즘의 체계적인 이해에 기여할 수 있을 것이다.

  • PDF

온도변화를 고려한 유동기체의 방전특성에 관한 연구 (Characteristics of Sparkover Discharge In Flowing Gas with Variation of Temperature)

  • 김상구;오재열;송현직;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.310-313
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing air with variation of Temperature(T). Also, We studied changes of discharge pattern for constant input power by adjustment of the Reynolds number(Re) and T. The essentiales of this paper are as followers. The invaluable equation obtained from this experiment is [%]$\frac{Vs}{Re}$=A+B${\varepsilon}^{c{\cdot}Re}$ where A=10.5 B=120 $C=-3.00{\times}10^{-5}$ Breakdown Voltage for Variation of temperature in static air is given by expression Vs = K (23.98 ${\rho}$d+6.8 ${\sqrt}{{\rho}d}$)[kV] The discharge pattern can be controlled by adjustment of the Reynolds number.

  • PDF

온도변화를 고려한 유동공기의 방전특성에 관한 연구 (Characteristics of Sparkover Discharge In Flowing Air With Variation of Temperature)

  • 김상구;오재열;송현직;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.28-32
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing air with variation of Temperature(T). Also, We studied changes of discharge pattern for constant input power by adjustment of the reynolds number(Re) and T. the essentials of this paper are as followers. The invaluable equation obtained from this experiment is [%] {{{{ { Vs} over {Re } = A·LOG10 Re + B}}}} w here A,B : constant Breakdown Voltage for variation of temperature at 1[m/s] is given by expression Vs = K(23.98 pd + 6.8{{{{ SQRT { pd} }}}}) [kV] where K = 0.331 The discharge pattern can be controlled by adjustment of the Reynolds number

  • PDF