• Title/Summary/Keyword: Discharge Control

Search Result 1,425, Processing Time 0.029 seconds

Studies on the Control of AtoN Charge and Discharge Controller (항로표지 충·방전조절기의 제어에 관한 연구)

  • Ye, Seong-hyeon;Han, Soonhee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.654-657
    • /
    • 2014
  • In this paper, we proposed a short distance control method of AtoN charge and discharge regulator. The proposed control measures, was constructed by applying the communication standards NEMA018 of AtoN and control function analysis of the charge and discharge regulator that has been operating in the country. By using the control method is proposed, while maintaining the waterproof without product degradation, there is an advantage that can communicate control wired or wireless. Also, it is possible to ensure the accessibility of the charge and discharge regulator in operation, it is effective for maintenance. In this paper, installed the application to control the charge and discharge regulator to the smart-phone. by using a PC and Blue-tooth communication, to examine the effectiveness of the control information. Future, control method of power controller, can provide a national standard.

  • PDF

The Development of the Automatic Discharge Acquisition & Management System (ADAMS) using Ubiquitous Technique

  • Park, Jae-Young;Oh, Byoung-Dong;Jeon, Seon-Mee;Kim, Jae-Bok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.488-493
    • /
    • 2006
  • Accurate river discharge is the most important factor in managing river basins and for successfully maintaining total maximum daily loads in Korea. It is not easy to measure the discharge directly in large rivers owing to physical and environmental constraints, even after investing much time and money. Recently, to overcome these historical drawbacks in river discharge measurement, we have developed the Automatic Discharge Acquisition & Management System (ADAMS) that scans the river cross-section and measures each cell $(1m{\times}1m)$ velocity using HADCP. The hardware system is composed of an HADCP sensor and winch, as well as a PC and software system for the discharge calculation module and hardware control module. It is controlled remotely via the internet and uses the velocity-depth integration method and the velocity-contour method for calculating river discharges. The characteristics of ADAMS are a ubiquitously accessible system, featuring real time automatic discharge measurement, remote control via the internet. The results using ADAMS at the Jindong stage site show less than 5% uncertainty and are 4 times more efficient than the ADCP & Q-boat system. This system can be used to measure any large river, river mouth or tributary river affected by backwater, all of which have a very difficult measuring real time discharge. The next generation of ADAMS will feature an upgrade to increase portability and GPS integration.

  • PDF

Embedded System Design for Precision Control of the Secondary Battery Charge/Discharge Production Process (2차 전지 충.방전 생산 공정 정밀제어를 위한 임베디드 시스템 개발)

  • Choi, Joong-Hyun;Kim, Jong-Tae;Oh, Jae-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.150-152
    • /
    • 2004
  • The battery charge/discharge process, the final step of the secondary battery production process, requires real-time precision controls for improving both lifetime and performance of the battery cell. In this paper, we present embedded system design for precision control of the secondary battery charge/discharge production process using low power embedded processor based on embedded linux. This system receive charge/discharge command from the main server through ethernet. Compared to existing charge/discharge control system, our design makes low cost and precision control system possible.

  • PDF

Analysis of the Dynamic Characteristics of the Underwater Discharge System using a Linear Pump (선형펌프 방식 수중발사 시스템의 동특성 해석)

  • Park, In-Ki;Jung, Chan-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.3 s.22
    • /
    • pp.11-17
    • /
    • 2005
  • In this paper, the mathematical model of the underwater discharge system using a linear pump is derived and the suitable opening pattern of a flow control valve which satisfies the discharge performance requirements is obtained through the underwater discharge simulations. The simulation results show that the dynamic characteristics of a projectile are greatly affected by the opening pattern of the flow control valve, however, hardly by the diving depth. It is anticipated that the simulation model can be used to derive the design parameters and analyze the performance of the designed underwater discharge system using a linear pump.

Discharging Voltage Control with Error Detecting for Search light of Ship (선박용 탐사조명 전원장치의 방전개시전압 제어와 조명 이상검출)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.8-17
    • /
    • 2008
  • This paper presents a stable lighting method for HID lamp for ship from initial discharging current limit with discharging voltage control. The output voltage of the proposed control scheme is boosted for ignition, and the charging voltage is decreased by the resistor discharging. The proposed controller fires the initial discharge at the designed discharging voltage to limit the discharge current. After the discharging, constant current controller is used for brightness in steady state. The proposed control scheme can limit the initial discharge current using the starting point control without a complex voltage controller. so it can improve the life-time of HID lamp and get a stable discharge from restricted the initial discharge current. In order to improve the protection of the system, a simple instantaneous error detecting circuit for open state and short state of HID lamp is used. The proposed error detecting of HID lamp can protect the power system of lamp control. The effectiveness of the proposed controller is verified from the experiments of practical 2.5[kW] HID search light for ship.

The Study on the Properties of He Glow discharge in a Dielectric Barrier Discharge (DBD) Model (DBD 전극구조에서의 He 가스 글로우방전 특성연구)

  • So, Soon-Youl
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.214-220
    • /
    • 2018
  • Light sources induced by gas discharge using rare gases have been widely used in the thin film deposition, the surface modification and the polymer etching. A dielectric barrier discharge (DBD) has been developed in order to consistently emit light and control the wavelength of the emission light. However, much research on the characteristics of the movement of discharge particles is required to improve the efficiency of the light lamp and the life-time of the light apparatus in detail. In this paper, we developed a He DBD discharge simulation tool and investigated the characteristics of discharge particles which were electrons, two positive ions ($He^+$, $He_2^+$) and 5 excited particles ($He^*(1S)$, $He^*(3S)$, $He^*$, $He^{**}$, $He^{***}$). The discharge currents showed the transition from pulse mode to continuous mode with the increase of power. With the accumulated charges on the barrier walls, the discharge current was rapidly increased and caused oscillation of the discharge voltage. As the gas pressure increased, $He_2^+$ and $He^*(3S)$ became the dominant activated particles. The input power was mostly consumed by electrons and $He_2^+$ ion. And the change curve showed that power consumption by electrons increased more with gas pressure than with source voltage or frequency.

Flow Actuation by DC Surface Discharge Plasma Actuator in Different Discharge Modes

  • Kim, Yeon-Sung;Shin, Jichul
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.339-346
    • /
    • 2015
  • Aerodynamic flow control phenomena were investigated with a low-current DC surface discharge plasma actuator. The plasma actuator was found to operate in three different discharge modes with similar discharge currents of about 1 mA or less. Stable continuous DC discharge without audible noise was obtained at higher ballast resistances and lower discharge currents. However, even with continuous DC power input, a low-frequency self-pulsed discharge was obtained at lower ballast resistances, and a high-frequency self-pulsed discharge was obtained at higher set-point currents and higher ballast resistances, both with audible noise. The Schlieren image reveals that the low-frequency self-pulsed mode produces a synthetic jet-like flow implying that a gas heating effect plays a role, even though the discharge current is small. The high-frequency self-pulsed mode produces pulsed jets in a tangent direction, and the continuous DC mode produces a steady straight pressure wave. Particle image velocimetry (PIV) images reveal that the induced flow field by the low-frequency self-pulsed mode has flow propagating in the radial direction and centered between the electrodes. The high-frequency self-pulsed mode and continuous DC mode produce flow from the anode to the cathode. The perturbed region downstream of the cathode is larger in the high-frequency self-pulsed mode with similar maximum speeds.

Estimation of Sediment Discharge Controlled by Sediment-filled Check-dam in a Forested Catchment (산림유역의 만사 사방댐에 의한 토사유출 조절 효과 추정)

  • Seo, Jung Il;Chun, Kun Woo;Song, Dong Geun
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.3
    • /
    • pp.321-329
    • /
    • 2016
  • To estimate the sediment discharge controlled by sediment-filled check-dam and thereby enhancing factor for check-dam design and dredging criteria, we surveyed slope failures and stream-bed fluctuation caused by geomorphic disturbances (i.e., landslides and debris flows) in Inje, Gangwondo. In general, check-dams play roles for restraining and controlling sediment discharge within a section under the design equilibrium gradient and a section under the design flood gradient, respectively. The results in this study showed same pattern: that is, the closed type check-dam, which has a design restraint sediment discharge of $2,111m^3$, estimated to control a sediment discharge of $3,996m^3$ in the stream section within 250 m right upper area immediately after the disturbances occurred in 2006. As a result, a design control sediment discharge of the check-dam was larger than its design restraint sediment discharge. This represents that the check-dam is still having an own function for controlling sediment discharge although it exceeded the designed capacity by the sediment discharged from upstream during the disturbances. Our finding suggests that the sediment discharge controlling of check-dam may need to be evaluated separately from its sediment discharge restraint. Currently, the country, however, does not consider the design control (or restraint) sediment discharges, based on the actual field survey, as criteria for check-dam design and/or dredging work. Therefore, the accumulation of the quantitative data is required to support that check-dam has functions for both restraining and controlling sediment discharge. This would be a way to develop our erosion control technology to the scientific technology equipped with a more objective and systematic aspects.

The Improved Characteristics of the Stand-alone PV System by the Independent Battery Control Method (밧데리 개별 제어 방식에 의한 소규모 독립형 태양광 발전 시스템의 특성 개선)

  • 강신영;이양규;김광헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.482-489
    • /
    • 2002
  • This paper studies the stand-alone photovoltaic system for the solar lighting lamp. The solar lighting lamp has PV modules, batteries, and charge & discharge system. The charge efficiency is improved for the control of each battery which is divided the charge from the discharge to change the structure of existing solar lighting lamp charge & discharge system. so, the charge and discharge times are reduced of 50% and the depth of discharge control can be controlled in the discharge cut off voltage. It can be effective of the battery use. If a battery is out of order, this system can be executed for a regular period. So we saved the repair cost and developed of system's stabilization. It Is possible to make economical effects to apply for solar lighting lamp used photovoltaic system.

Study on Characteristics of DBD Plasma Actuator as Design Parameters for Plasma Flow Control (플라즈마 유동제어를 위한 DBD 플라즈마 액츄에이터의 설계변수에 따른 특성 연구)

  • Yun, Su-Hwan;Kwon, Hyeok-Bin;Kim, Tae-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.6
    • /
    • pp.492-498
    • /
    • 2012
  • Characteristics of DBD(Dielectric Barrier Discharge) plasma actuator as design parameters were investigated for plasma flow control. Flow velocity and power consumption of the DBD plasma actuator were measured according to the design parameters such as discharge voltage and frequency, gap, width and length of electrode, and the thickness of dielectric barrier. The flow velocity and power consumption increased as the discharge voltage and frequency increased. As the electrode gap increased, the flow velocity increased with decreasing the power consumption, whereas high voltage was required for the plasma discharge. The flow velocity increased as the upper-electrode width decreased, and as the lower-electrode width increased at the constant power consumption. The performance of the DBD plasma actuator can be estimated at the given discharge and geometry conditions.