• 제목/요약/키워드: Discharge Control

검색결과 1,425건 처리시간 0.029초

제어전극을 갖는 방전소자의 방전개시전압 설계에 관한 연구 (A Study on the Design of Discharge Voltage of Discharge Element with Control Electrode)

  • 박근석;최준웅;이대동
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1512-1516
    • /
    • 2018
  • The power system and control system constantly reveals surge voltage such as switching surge of lighting devices and power conversion devices, operating and stops surge of rotating devices, charge & discharge surge, opening & closing surge of circuit breakers and the like. Such a surge voltages can cause damage or malfunction of the element such as CPU, Memory, semiconductor etc. In the industry, in order to protect the system from the surge voltage, a surge protector with low discharge starting voltage, fast response time, and low capacitance is required, and technical development research for that is ongoing. In this paper, in order to solve the problem of the existing GDT discharge tube not discharging from the transient voltage which is higher than the commercial voltage and lower than the discharge voltage of the discharge element, we have developed a discharge element having the control electrode & control circuit. The discharge element having the control electrode and the control circuit can control the discharge voltage according to the needs of the consumer and can satisfy the requirement of the discharge element and the technology of the surge protector downsizing technology and the surge protection technology. It is judged to be effective for development.

정유량 밸브의 카트리지의 오리피스 구멍의 유출계수 (Discharge Coefficients of Orifice Hole in the Cartridge of Constant Flow Control Valve)

  • 유선학;강승덕;양의석;박경암
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.305-308
    • /
    • 2004
  • The constant flow control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have similar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the constant flow control valve was developed. The performance of this control valve is effected by hole area and discharge coefficients of the cartridge holes. The discharge coefficients of orifice hole in the cartridge were testes with various sizes of holes and various flow direction in the holes. The discharge coefficients decreased as the hole size increased due to the collision at the cartridge wall of water jet. The effects of the flow direction at the hole were not significant on the discharge coefficients.

  • PDF

어도의 적절한 이용을 위한 유지유량 평가 (Estimation of Maintenance Flow for Suitable Utilization of Fishway)

  • 김석규;김철;김성환;고광용
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.281-287
    • /
    • 2009
  • Achieved monitoring regularly about fishway that is a intake dam belongings to Kyeongchon for 5 years. Result that achieve monitoring, discovered pressing issue of opening and closing degree of discharge control part in fishway. In this research, analyze discharge relation with fishway and intake sluice and presented operation plan of opening and closing of discharge control part. Investigated necessity intake discharge and benefited area to analyze relation of discharge that is flowed in fishway and discharge escaping by intake sluice. When opened discharge control part step by step gradually, analyzed discharge. Compared with survey discharge making ration curve of fishway and intake sluice using orifice and submerged weir formula. Because operation of intake dam is necessary intake discharge and upriver inflow discharge by time, operation uses by survey discharge and calculated opening discharge of fishway by opening discharge of intake sluice via monthly inflow discharge. To sum up, calculated floodgate opening height of fishway by water level to present maintenance standard of intake dam.

하도내 조절수문 방류특성 해석 (Analysis of Discharge Characteristics for a Control Gate in a River)

  • 손광익
    • 대한토목학회논문집
    • /
    • 제31권4B호
    • /
    • pp.309-314
    • /
    • 2011
  • 하류수위의 영향을 받는 하도 내 조절수문의 경우 조절수문의 기하학적 형상은 물론 상 하류 수위에 따라 방류특성이 변화하므로 효율적 수위조절 및 수자원 관리를 위해서는 정확한 개도별 방류능 산정이 요구된다. 최근 4대강 살리기 사업으로 인하여 보의 건설과 함께 조절수문이 많이 설치되고 있으나 국내에서는 조절수문 개도에 따른 방류형태 분류기준 및 방류능 산정에 대한 연구를 찾아보기 힘든 실정이다. 따라서 본 연구에서는 특정 조절수문에 대한 수리모형실험을 통하여 방류형태(자유위어, 수중위어, 자유오리피스, 수중오리피스)를 판단할 수 있는 주요 인자를 찾고 분류기준을 검토하여 조절수문 운영을 위한 기초자료를 제시하였다. 게이트 개도높이와 상류수심의 비($h_g/h_1$), 하류수심과 게이트 개도높이의 비($h_3/h_g$)와 하류수심과 상류수심의 비($h_3/h_1$)를 하도 내 조절수문의 개도 및 상 하류 수위에 따른 방류형태를 판단할 수 있는 주요 인자로 선정하고 방류형태 분류기준 값을 제안하였다. 또한 본 연구에서 유도된 각 방류형태별 유출계수 및 방류능 산정공식으로 예측된 유량과 모형에서의 실측유량을 비교하여 연구결과의 적용성을 검증하였다.

PDP의 가격절감을 위한 새로운 방전 AND Gate 및 구동기술에 관한 연구 (A Study on the New Discharge AND Gate and Drive Scheme for the Cost Down of the PDPs)

  • 염정덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권6호
    • /
    • pp.267-273
    • /
    • 2003
  • The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

환경오염의 방지시설의 운영에 관한 실태조사 (A Study on the Wastewater and Air Pollution, Noise and Vibration Management and Discharge Control at the Industries)

  • 김남천;우세홍;구성회
    • 환경위생공학
    • /
    • 제1권1호
    • /
    • pp.81-96
    • /
    • 1986
  • 510 random samples were studied during the months of may through November 1985 at the various industries and conclustions were made as follows; 1. $43.94\%$ of the plants studied operated their plants with semiautomatic control system, and better efficiency were observed at the plants where automatic control systems emplorid and also large industries showed more tendency adopting the automatic plant control system. 2. Overall efficiency of the treatment plants were seen much higher at the first and secand discharge class categories then the lower discharge classes, $80.79\%$ of the plants were see their daily plant operation being controlled by the operator himself. 3. The main causes of the plant stopage and in efficient discharge control were found to be malfunctioning of the plants machineries and equipment or inadequate decision made by the management to save chemicals or electricity. 4. The study showed $60\%$ of the industry treated their wastwater wholly and the rest discharged only with dilution without receiving any further treatment, and this tendency pronounced at the 4th and 5th class discharge category industries. 5. $66.17\%$ of the industry had their storage capacity to accommodate the waste discharge during plants outage while $92.67\%$ of the air pollution discharge industries had no means for the plant outage. 6. $56.77\%$ of the studied industry maintained 24 hour operation of their discharge control systems whill $18.67\%$ of air pollution discharge industries and $10.53\%$ of the waste water discharge industries showed no control effort during the night.

  • PDF

플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구 (A Study on the Discharge AND Gate of Plasma Display Panels)

  • 손현성;채승엽;염정덕
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

The Effects of a Home-Visiting Discharge Education on Maternal Self-esteem, Maternal Attachment, Postpartum Depression and Family Function in the Mothers of NICU Infants

  • Ahn Young-Mee;Kim Mi-Ran
    • 대한간호학회지
    • /
    • 제34권8호
    • /
    • pp.1468-1476
    • /
    • 2004
  • Purpose: A quasi-experimental study was performed to investigate the effects of a home visiting discharge education program on the maternal self-esteem, attachment, postpartum depression and family function in 35 mothers of neonatal intensive care unit (NICU) infants. Methods: Twenty-three mothers in the intervention group received the home visiting discharge education while 12 mothers in the control group received the routine, hospital discharge education. Baseline data was collected in both groups one day after delivery. The intervention group received the home visiting discharge education while the control group did the routine hospital-based discharge education. The questionnaire including the data on maternal self-esteem, attachment, postpartum depression and family function were collected within 1 week after the discharge by mail. Results: The scores of maternal self-esteem, and attachment were significantly increased, and the postpartum depression and the family function score were decreased after the home visiting discharge education in intervention group. There were no changes in these variables before and after the routine hospital-based discharge education in control group. Conclusion: These results support the beneficial effects of home visiting discharge education on the maternal role adaptation and family function of the mothers of NICU infants.

방전에너지 제어에 의한 최소점화에너지의 고찰 (A Study on Minimum Ignition Energy by Controlled Discharge Energy)

  • 최상원;대택돈
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.36-39
    • /
    • 2007
  • It is important to know Minimum Ignition Energy(MIE) of flammable materials for ignition hazard of chemical processes etc.. Currently a capacitor discharge is used mainly to measure the MIE. Then, it is impossible to control actively discharge energies and discharge time because the MIE measurement uses a high voltage capacitor and fixed capacitor. However, the control of discharge energy and discharge time will be convenient if self-sustain discharge is used. In this paper, we measured the MIE by self-sustain discharge of a pulse shape to propose the new measuring method of the MIE. AS a result, ignition energies are increased gradually as discharge duration time gets longer, and discharge current grows larger. Also, an arc discharge and a glow discharge occurred during the experimental period, and the ignition by glow discharges happened when discharge duration time was $90{\mu}s$, discharge current was 8A and 1A Especially, the MIE occurred the 0.05mm and 0.08mm of the gap distance between discharge electrode in the same discharge duration time.

퇴원시 간호정보 제공이 개심술 환자의 지식, 신체증상, 상태불안 및 일상활동에 미치는 효과에 관한 연구 (The Effects of Nursing Information on knowledge, physical symptoms, state anxiety and daily activity levels of patients recovering from open heart surgery)

  • 김금순;유경희
    • 대한간호학회지
    • /
    • 제21권3호
    • /
    • pp.257-267
    • /
    • 1991
  • This study investigated the effects of nursing in formation given verbally and a booklet on the knowledge, Physical symptoms, anxiety and daily activities of patients recovering from open heart surgery from just before discharge to six weeks after discharge. The convenience sample was of patients who had undergone open heart surgery in Seoul National University Hospital. The first 25 patients who agreed to participate in the study became the control group. They did not receive the intentional information but the usual nursing care. The next 28 patients became the experimental group who received a booklet about their post-discharge care which was discussed with them by the researcher before discharge. This study used a non equivalent control group non - synchronized quasiexperimental design. The tools included a 30 item knowledge scale, a 9 item physical symptom scale, Spielberger's state anxiety scale, and a 28 item daily activity scale. The instruments were applied before discharge and at two and six weeks after discharge. For data analysis, frequency, t-test, Pearson's Correlational Coefficient and Cronbach's $\alpha$ were used. The results were as follows : 1. Information given through the booklet was effective in increasing the knowledge of patients recovering from open heart surgery. The experimental group's knowledge was higher at 2 weeks after discharge than prior to discharge (P<0.05). 2. There was no significant difference in physical symptoms between the two groups at two and six weeks after discharge. 3. Information given through the booklet was effective in decreasing the State Anxiety two weeks after discharge (P<0.001) but at six weeks after discharge, there was no significant difference in anxiety between the control and the experimental groups. 4. There was no significant difference in daily activity between the two groups at two and six weeks after discharge. 5. There was a negative correlation between knowledge at discharge and at 2 weeks and anxiety at 2 weeks after discharge. There was a positive correlation between knowledge at discharge and daily activity at 2 weeks after discharge. There was a negative correlation between knowledge at 2 weeks and Physical symptom at 6 weeks after discharge.

  • PDF