• Title/Summary/Keyword: Discharge Control

Search Result 1,425, Processing Time 0.031 seconds

A Study on the Design of Discharge Voltage of Discharge Element with Control Electrode (제어전극을 갖는 방전소자의 방전개시전압 설계에 관한 연구)

  • Park, Keun-Seok;Choi, Jun-Woong;Lee, Dae-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1512-1516
    • /
    • 2018
  • The power system and control system constantly reveals surge voltage such as switching surge of lighting devices and power conversion devices, operating and stops surge of rotating devices, charge & discharge surge, opening & closing surge of circuit breakers and the like. Such a surge voltages can cause damage or malfunction of the element such as CPU, Memory, semiconductor etc. In the industry, in order to protect the system from the surge voltage, a surge protector with low discharge starting voltage, fast response time, and low capacitance is required, and technical development research for that is ongoing. In this paper, in order to solve the problem of the existing GDT discharge tube not discharging from the transient voltage which is higher than the commercial voltage and lower than the discharge voltage of the discharge element, we have developed a discharge element having the control electrode & control circuit. The discharge element having the control electrode and the control circuit can control the discharge voltage according to the needs of the consumer and can satisfy the requirement of the discharge element and the technology of the surge protector downsizing technology and the surge protection technology. It is judged to be effective for development.

Discharge Coefficients of Orifice Hole in the Cartridge of Constant Flow Control Valve (정유량 밸브의 카트리지의 오리피스 구멍의 유출계수)

  • Yoo, Seon-Hak;Kang, Seung-Duk;Yang, Eui-Seok;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.305-308
    • /
    • 2004
  • The constant flow control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have similar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the constant flow control valve was developed. The performance of this control valve is effected by hole area and discharge coefficients of the cartridge holes. The discharge coefficients of orifice hole in the cartridge were testes with various sizes of holes and various flow direction in the holes. The discharge coefficients decreased as the hole size increased due to the collision at the cartridge wall of water jet. The effects of the flow direction at the hole were not significant on the discharge coefficients.

  • PDF

Estimation of Maintenance Flow for Suitable Utilization of Fishway (어도의 적절한 이용을 위한 유지유량 평가)

  • Kim, Seok-gyu;Kim, Chul;Kim, Seonghwan;Ko, Kwangyong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.281-287
    • /
    • 2009
  • Achieved monitoring regularly about fishway that is a intake dam belongings to Kyeongchon for 5 years. Result that achieve monitoring, discovered pressing issue of opening and closing degree of discharge control part in fishway. In this research, analyze discharge relation with fishway and intake sluice and presented operation plan of opening and closing of discharge control part. Investigated necessity intake discharge and benefited area to analyze relation of discharge that is flowed in fishway and discharge escaping by intake sluice. When opened discharge control part step by step gradually, analyzed discharge. Compared with survey discharge making ration curve of fishway and intake sluice using orifice and submerged weir formula. Because operation of intake dam is necessary intake discharge and upriver inflow discharge by time, operation uses by survey discharge and calculated opening discharge of fishway by opening discharge of intake sluice via monthly inflow discharge. To sum up, calculated floodgate opening height of fishway by water level to present maintenance standard of intake dam.

Analysis of Discharge Characteristics for a Control Gate in a River (하도내 조절수문 방류특성 해석)

  • Son, Kwang Ik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4B
    • /
    • pp.309-314
    • /
    • 2011
  • Analysis of discharge characteristics through control gates at river crossing structures is important for an effective water level control and water resources management. In recent years, many river control structures in four major rivers are under construction but only few researches on discharge characteristics at control gates could be found in Korea. The discharge characteristics depend on both shape of control gates and the effects of downstream water-depth. In this research, classification index for discharge patterns (free weir, submerged weir, free orifice, submerged orifice) through a control gate were reviewed with $h_g/h_1$, $h_3/h_g$, and $h_3/h_1$. Classification criteria of discharge patterns were also suggested. Representative discharge estimation equations for each discharge patterns were adopted and discharge coefficients were developed from a hydraulic model for a specific control gate which will be constructed in Nakdong river. Reliability of the derived discharge equation and coefficients were confirmed by comparisons between the real discharge in a model and the predicted discharge from the results of this research.

A Study on the New Discharge AND Gate and Drive Scheme for the Cost Down of the PDPs (PDP의 가격절감을 위한 새로운 방전 AND Gate 및 구동기술에 관한 연구)

  • 염정덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.6
    • /
    • pp.267-273
    • /
    • 2003
  • The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

A Study on the Wastewater and Air Pollution, Noise and Vibration Management and Discharge Control at the Industries (환경오염의 방지시설의 운영에 관한 실태조사)

  • Kim Nam Cheon;Woo Se Hong;Koo Sung Hoi
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.81-96
    • /
    • 1986
  • 510 random samples were studied during the months of may through November 1985 at the various industries and conclustions were made as follows; 1. $43.94\%$ of the plants studied operated their plants with semiautomatic control system, and better efficiency were observed at the plants where automatic control systems emplorid and also large industries showed more tendency adopting the automatic plant control system. 2. Overall efficiency of the treatment plants were seen much higher at the first and secand discharge class categories then the lower discharge classes, $80.79\%$ of the plants were see their daily plant operation being controlled by the operator himself. 3. The main causes of the plant stopage and in efficient discharge control were found to be malfunctioning of the plants machineries and equipment or inadequate decision made by the management to save chemicals or electricity. 4. The study showed $60\%$ of the industry treated their wastwater wholly and the rest discharged only with dilution without receiving any further treatment, and this tendency pronounced at the 4th and 5th class discharge category industries. 5. $66.17\%$ of the industry had their storage capacity to accommodate the waste discharge during plants outage while $92.67\%$ of the air pollution discharge industries had no means for the plant outage. 6. $56.77\%$ of the studied industry maintained 24 hour operation of their discharge control systems whill $18.67\%$ of air pollution discharge industries and $10.53\%$ of the waste water discharge industries showed no control effort during the night.

  • PDF

A Study on the Discharge AND Gate of Plasma Display Panels (플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구)

  • 손현성;채승엽;염정덕
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

The Effects of a Home-Visiting Discharge Education on Maternal Self-esteem, Maternal Attachment, Postpartum Depression and Family Function in the Mothers of NICU Infants

  • Ahn Young-Mee;Kim Mi-Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.8
    • /
    • pp.1468-1476
    • /
    • 2004
  • Purpose: A quasi-experimental study was performed to investigate the effects of a home visiting discharge education program on the maternal self-esteem, attachment, postpartum depression and family function in 35 mothers of neonatal intensive care unit (NICU) infants. Methods: Twenty-three mothers in the intervention group received the home visiting discharge education while 12 mothers in the control group received the routine, hospital discharge education. Baseline data was collected in both groups one day after delivery. The intervention group received the home visiting discharge education while the control group did the routine hospital-based discharge education. The questionnaire including the data on maternal self-esteem, attachment, postpartum depression and family function were collected within 1 week after the discharge by mail. Results: The scores of maternal self-esteem, and attachment were significantly increased, and the postpartum depression and the family function score were decreased after the home visiting discharge education in intervention group. There were no changes in these variables before and after the routine hospital-based discharge education in control group. Conclusion: These results support the beneficial effects of home visiting discharge education on the maternal role adaptation and family function of the mothers of NICU infants.

A Study on Minimum Ignition Energy by Controlled Discharge Energy (방전에너지 제어에 의한 최소점화에너지의 고찰)

  • Choi, Sang-Won;Ohsawa, Atsushi
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.36-39
    • /
    • 2007
  • It is important to know Minimum Ignition Energy(MIE) of flammable materials for ignition hazard of chemical processes etc.. Currently a capacitor discharge is used mainly to measure the MIE. Then, it is impossible to control actively discharge energies and discharge time because the MIE measurement uses a high voltage capacitor and fixed capacitor. However, the control of discharge energy and discharge time will be convenient if self-sustain discharge is used. In this paper, we measured the MIE by self-sustain discharge of a pulse shape to propose the new measuring method of the MIE. AS a result, ignition energies are increased gradually as discharge duration time gets longer, and discharge current grows larger. Also, an arc discharge and a glow discharge occurred during the experimental period, and the ignition by glow discharges happened when discharge duration time was $90{\mu}s$, discharge current was 8A and 1A Especially, the MIE occurred the 0.05mm and 0.08mm of the gap distance between discharge electrode in the same discharge duration time.

The Effects of Nursing Information on knowledge, physical symptoms, state anxiety and daily activity levels of patients recovering from open heart surgery (퇴원시 간호정보 제공이 개심술 환자의 지식, 신체증상, 상태불안 및 일상활동에 미치는 효과에 관한 연구)

  • 김금순;유경희
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.257-267
    • /
    • 1991
  • This study investigated the effects of nursing in formation given verbally and a booklet on the knowledge, Physical symptoms, anxiety and daily activities of patients recovering from open heart surgery from just before discharge to six weeks after discharge. The convenience sample was of patients who had undergone open heart surgery in Seoul National University Hospital. The first 25 patients who agreed to participate in the study became the control group. They did not receive the intentional information but the usual nursing care. The next 28 patients became the experimental group who received a booklet about their post-discharge care which was discussed with them by the researcher before discharge. This study used a non equivalent control group non - synchronized quasiexperimental design. The tools included a 30 item knowledge scale, a 9 item physical symptom scale, Spielberger's state anxiety scale, and a 28 item daily activity scale. The instruments were applied before discharge and at two and six weeks after discharge. For data analysis, frequency, t-test, Pearson's Correlational Coefficient and Cronbach's $\alpha$ were used. The results were as follows : 1. Information given through the booklet was effective in increasing the knowledge of patients recovering from open heart surgery. The experimental group's knowledge was higher at 2 weeks after discharge than prior to discharge (P<0.05). 2. There was no significant difference in physical symptoms between the two groups at two and six weeks after discharge. 3. Information given through the booklet was effective in decreasing the State Anxiety two weeks after discharge (P<0.001) but at six weeks after discharge, there was no significant difference in anxiety between the control and the experimental groups. 4. There was no significant difference in daily activity between the two groups at two and six weeks after discharge. 5. There was a negative correlation between knowledge at discharge and at 2 weeks and anxiety at 2 weeks after discharge. There was a positive correlation between knowledge at discharge and daily activity at 2 weeks after discharge. There was a negative correlation between knowledge at 2 weeks and Physical symptom at 6 weeks after discharge.

  • PDF