• Title/Summary/Keyword: Discharge Analysis Program

Search Result 183, Processing Time 0.035 seconds

Study on Estimation and Application of Discharge Coefficient about Nonpoint Source Pollutants using Watershed Model (유역모형을 이용한 유량조건별 배출계수 산정 및 활용방안 연구)

  • Hwang, Ha-Sun;Rhee, Han-Pil;Park, Jihyung;Kim, Yong-Seok;Lee, Sung-Jun;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.653-664
    • /
    • 2015
  • TPLMS (Total water pollutant load management system) that is the most powerful water-quality protection program have been implemented since 2004. In the implementation of TPLMS, target water-quality and permissible discharged load from each unit watershed can be decided by water-quality modeling. And NPS (Non-point sources) discharge coefficients associated with certain (standard) flow are used on estimation of input data for model. National Institute of Environmental Research (NIER) recommend NPS discharge coefficients as 0.15 (Q275) and 0.50 (Q185) in common for whole watershed in Korea. But, uniform coefficient is difficult to reflect various NPS characteristics of individual watershed. Monthly NPS discharge coefficients were predicted and estimated using surface flow and water-quality from HSPF watershed model in this study. Those coefficients were plotted in flow duration curve of study area (Palger stream and Geumho C watershed) with monthly average flow. Linear regression analysis was performed about NPS discharge coefficients of BOD, T-N and T-P associated with flow, and R2 of regression were distributed in 0.893~0.930 (Palger stream) and 0.939~0.959 (Geumho C). NPS Discharge coefficient through regression can be estimated flexibly according to flow, and be considered characteristics of watershed with watershed model.

Sensitivity Analysis of Debris Flow Simulation in Flo-2D Using Flow Discharge and Topographic Information (유량과 지형조건에 따른 Flo-2D에서의 토석류 확산 민감도 분석)

  • Kim, Namgyun;Jun, Byonghee
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.547-558
    • /
    • 2022
  • In August 2020, a debris flow occurred in Gokseon, Jeollanam-do, that resulted in the death of five residents. In this study area, high-resolution 0.03 m topographic information was generated through photogrammetry, and the amount of soil movement/loss was measured. In addition, sensitivity analysis was performed for flow depth, flow velocity, and debris flow area with the program Flo-2D using the difference in simulation parameter that discharge and topographic information. Wth increasing debris flow input discharge, increases were seen in flow depth, flow velocity, and debris flow area, as ell as in the gap in results from high-resolution topographic information and low-resolution topographic information. Also, when high-resolution topographic information was used, the results were similar to the actual (measured) flow direction of the debris flow. Therefore, the application of high-resolution topographic information increases the accuracy of the debris flow analysis results compared with low-resolution information. Results could be further imporved in the future by considering geological information such as yield stress and viscosity.

Development of educational programs for managing medical information utilizing medical data generation and analysis techniques (의료 데이터 발생과 분석기술을 활용한 의료정보관리 교육용 프로그램 개발)

  • Choi, Joonyoung
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.377-386
    • /
    • 2017
  • This study has developed a medical information management educational program that can improve the management ability of medical information. The educational medical information management program was developed for 8mnths uing VB. The database utilized the ACCESS Database, which allows learners to easily understand and understand the structure of the data. The learners enter data in the discharge analysis and the cancer registration program and the incomplete program after analyze the medical records. After entering and saving data, medical information management programs can be used to understand and analyze the structure of the database to generate medical information. The educational programs can improve the ability of learners to manage medical information by extracting the necessary data from the database directly through SQL and creating various medical information. However, although the medical information management program is an educational program, there is no evaluation system for the learners program operation. Accordingly, the next studies should develop the assessment system of the medical information management program for learners evaluation.

Responsiveness Comparisons of Self-Report Versus Therapist-Scored Functional Capacity for Workers With Low Back Pain

  • Choi, Bongsam;Park, So-Yeon
    • Physical Therapy Korea
    • /
    • v.19 no.3
    • /
    • pp.91-97
    • /
    • 2012
  • The primary aim of this study was to compare responsiveness of self-report by worker and therapist-scored functional capacity instrument. Self-report and therapist-scored interval-level person measures and item difficulties were compared at admission and discharge. Therapist and worker ratings were collected on 230 clients from 27 rehabilitation sites using the newly developed Occupational Rehabilitation Data Base (ORDB) functional capacity instrument. ORDB comprises several subscales measuring relevant variables of "a return-to-work model" in work-related rehabilitation clinics. The functional capacity scale deals with 10 DOT job factors. The rating scale categories were 1-severely impaired, 2-moderately impaired, 3-mildly impaired, and 4-not impaired. Only data from clients with low back pain (n=98) with complete data (both admission and discharge scores) were used for the present study. Therapists and workers completed the functional capacity instrument at admission and discharge. Rasch analysis [1-parameter item response theory model (IRT)] was applied to calibrate item difficulty and person ability measure of therapist and workers ratings. Effect sizes for therapist and self-report ratings were slightly different, .69 and .30, respectively. Therapist and worker ratings were more consistent at discharge (r=.54) than at admission (r=.32). Workers have a tendency to be more severe in their ratings (show higher item difficulties) than therapists at admission and discharge. Therapists and workers report similar magnitudes of improvement following treatment program. These findings challenge the belief that injured workers may unreliable source for monitoring therapeutic outcomes. Self-report measures have the advantage of conserving therapist time for treatment (versus evaluation). While the therapist and self-report ratings are comparable at discharge, there is less consistency at admission. Comparable therapist-worker ratings may be achieved by controlling for rating severity using IRT methodologies.

Outcomes of Home Care Service for Coronary Artery Bypass Graft (관상동맥우회술 환자의 가정간호 효과)

  • Baek, Hee-Chong
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.10 no.2
    • /
    • pp.123-131
    • /
    • 2003
  • This study was to compare the functional status. complication and readmission rates. and client satisfaction with nursing care of home-based care and hospital-based care for clients with Coronary Artery Bypass Graft. Raw data were collected by interviewing and reviewing charts of 41 clients with Coronary Artery Bypass Graft between June 2001 and July 2002 at an university hospital located in Seoul. Korea. Out of 41 clients. 15 were in home care group and 26 were in hospitalization group. The baseline characteristics of the groups were almost identical. Mean age was 61.7 and 75.6% of clients being male. For home care group. the data collection was made at discharge and at termination of home care. and for hospitalization group. at discharge and at the first visit of outpatient department. Complication and readmission rates were investigated at one month after operation. Collected data were then analysed by conducting Chi-square test. Wilcoxon rank sum test. and Wilcoxon signed ranks test with SPSS program. The level of significance was .05. The results of the study are summarized as follows: 1. Postoperative length of stay of the home care group was shorter than that of hospitalization group by 1. 14 days(8.45 days vs. 9.59 days). On average. 1.8 home visits per client were observed. 2. The functional status (Barthel Index) at the termination of home care was significantly increased from that at discharge. For hospitalization group. a significant increase was observed between the functional status at the discharge and that at the first visit of outpatient department. The differencies in incremental of the scores. between the groups. were however not significant. 3. Complication and readmission rates; no statistically significant difference between the groups was observed. 4. The client satisfaction with nursing care (CSS) at termination of home care was significantly higher than that at hospital discharge. In conclusion. the outcomes of the analysis suggest that the home care benefits clients with Coronary Artery Bypass Graft. Client satisfaction with nursing care rises at termination of home care as compare to that measured at hospital discharge. Meanwhile. there was no significant differences in functional status. and complication and readmission rates. Further. home care reduced the length of stay in hospital.

  • PDF

A Preliminary Study for Expending of Hospital-Based Horne Health Care Coverage - Focused on Accident Inpatients Who has the Workers Compensation Insurance - (병원중심 가정간호사업 관리대상범위 확대를 위한 기초연구)

  • Lee, Sook-Ja;Lee, Jin-Kyung;Ryu, Ho-Sihn
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.5-18
    • /
    • 1999
  • This study was attempt to encourage for developing on rehabilitation delivery system and programs as a substitute service instead of hospitalization for accident patients at work, such as hospital based home health care nursing service. It needs vary substitutes service of hospitalization to curtail the length of stay for inpatients who were hospitalized with workers compensation insurance. It focused on developing an estimation of early discharge day of accident inpatients based on a detail statement of treatment for 115 inpatients who were hospitalized at General Hospital in 1997. This study has four specific purpose as follows. First, to find out the status of health service utilization. Second, to estimate the early discharge days and income increasing effect based on the early discharge for those patients. Third, to identify the factors to affect total medical expenditure and the length of stay for those inpatients. Forth, to figure out the need of utilizing home health care nursing service for accident patients. In order to analyze of the length of stay and medical expenditure for inpatients who were hospitalized due to the accident, the authors conducted with micro-analysis and macroanalysis from medical records and medical expenditure records. Micro-analysis was done by nominal group discussion of 4 expertise with the critical criteria. such as a decrease in the amount of treatment after surgery, treatments, tests, drugs and changes in the tests consistency, drug methods, vital signs, start of ROM exercise, doctor's order, patient's outside visiting ability, stable conditions. In addition to identify affected variables for medical expenditure. the length of stay and income effect due to early discharge day, the data was analyzed with multiple regression analysis and linear regression analysis model by SPSS-PC for windows and Excell program. Results of this study as follows. First, the mean length of stay was 37.1 days, whereas the mean length of stay due to early discharge was 28.2 days at the hospital. The estimation of early discharge days were shown that depends on the length of stay. The longer length of stay, the longer length of early discharge days, such as under 7 days length of stay patients was to estimated the mean length of stay was 4.9 days and early discharge days was 4.6. whereas the mean length of stay was 122.6 days and early discharge days was 92.0 respectively. The mean medical expenditure per day were found to be 133.409 Won. whereas the mean medical expenditure per day was shown negative linear trends according to the length of stay at the hospital. The estimation results of the income effect due to 11 early discharge days per bed was around 2,150,000 won. However, it means not the real benefits from early discharge, but the income increasing amount without considering medical prime cost in general hospital. Therefore, it needs further analysis on the cost containments and benefits under the considering as well turn over rates per bed as the medical prime costs. The length of stay was most significant and the sign was positive to the total medical expenditure, as expected. Surgery and patient's residential area also an important variable in explaining medical expenditure. The level of complications was most significant variable in explaining the length of stay. The level of the needs on horne health care nursing service which can be used for early discharge accident patients were shown very high. The needs distribution varied from 65.5% of patients and 88.9% of caregivers, to 96.4% of doctors, and 99.1% of nurses. In addition horne health nurse responded that they can be managed the accident inpatients from early discharge. From these research findings. the following suggestions has been drawn it needs to develop strategies on rehabilitation delivery system in order to focused on consumer's side which is planned for 21 century health policy in Korea. Vary intermediate facilities and horne health care would have been developed in the community based for comprehensive rehabilitation services as a substitutes of hospitalization for shortening the length of stay of hospitalizations. In hospital based horne health care nursing service, it's available immediately to utilize for the patients who wanted rehabilitation services as a substitutes of hospitalization under the cooperations with workers compensation insurance company.

  • PDF

Contamination Characteristics of Polymer Insulator using High Frequency Current Transformer (HF-CT센서를 이용한 고분자애자의 오손특성)

  • Park, Jae-June
    • The Journal of Information Technology
    • /
    • v.8 no.4
    • /
    • pp.1-7
    • /
    • 2005
  • Investigations of high frequency current transformer(HF-CT) waveform characteristics of the surface leakage on kaolin polluted EPDM polymer insulators have been performed. This work is part of a program aimed at examining the potential for HF-CT waveform characteristics analysis to provide information about the environment contaminants and environment condition of polymer insulators. The investigation reported examined the HF-CT waveform characteristics at high frequencies. The use of high frequency measurements for on-line applications reduces electrical inference. This work was peformed utilizing HF-CT to monitor of surface polluted discharge. It was found that HF-CT waveform frequency spectrum, magnitude depend on importantly the duration of the surface discharge activity.

  • PDF

A Study on the Design and the Dynamic Characteristics of Electro-Hydraulic Flow Control Servo Valve (전자유압 서보 유량제어밸브의 설계 및 동특성 향상에 관한 연구)

  • 김고도;김수태
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.151-160
    • /
    • 2000
  • An experimental and theoretical analysis for the improvement of dynamic characteristics and design of electro-hydraulic flow control servo valve are performed. The theoretical results are compared with the experimental step responses, and the important design parameters of an electro-hydraulic flow control servo valve are derived by using the simulation program. Simulation parameters of nozzle jet coefficient and orifice and spool valve discharge coefficient are given through experiment. The theoretical and experimental step response curves show that the valve gain depends on the fixed orifice and nozzle $ratio(R_on)$ and is maximum at $R_on=1.$ And drain orifice in the flapper - nozzle return line creates a small back pressure, which improves the performance fur the valve.

  • PDF

Numerical Investigation for Spray Angles of Dual Swirl Injector (Dual Swirl 인젝터의 분산각에 관한 해석적 연구)

  • 정해승;김선진
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.132-144
    • /
    • 2003
  • Numerical analysis of the spray angles of Dual swirl injector were investigated to obtain basic design data and to predict the combustion performance. Using the commercial thermal hydraulic program, discharge coefficients and spray angles were numerically analyzed with recess length, pressure drop, velocity ratio, mixture ratio and back hole length. Water was used as simulants for oxidizer and fuel, respectively to compare the experimental results. Swirl injectors were designed to inject oxidizer of 70.5g/s and fuel of 29.5g/s at the pressure drop of 1MPa and two recess lengths were considered. In addition, the effect of injector geometry coefficient and velocity ratio on the discharge coefficient was studied.

Analysis of Partial Discharge Signal Propagation Characteristics in GIS using FEM (FEM을 이용한 GIS내 부분방전 신호의 전파특성 해석)

  • Kim Jae-Chul;Lee Do-Hoon;Song Seung-Yeop;Kim Kwang-Whoa
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.624-629
    • /
    • 2004
  • The UHF electromagnetic waves excited by PD pulses propagate along the GIS busbar not only TEM mode, but also TE and TM mode. Generally the waves detected by the UHF sensors are those of high order modes and such waves can only propagate higher than cut-off frequency. In this paper, the cut-off frequency of 362[kV] GIS for each modes is computed and the electromagnetic field of each propagation modes is simulated by FEM(Finite Element Method) program. Frequency band of each TEmn/TMmn modes was determinated by simulation results and was discussed optimal position of UHF sensor from this results.