• Title/Summary/Keyword: Disc shape

Search Result 194, Processing Time 0.023 seconds

Clinical Safety Evaluation of Interbody Fusion Cage Based on Tunable Elastic Modulus of the Cellular Structure According to the Geometrical Variables (형상학적 변수에 따른 다공성 구조의 가변탄성계수를 기반으로 한 추간체유합보형재의 임상적 안전성 평가)

  • Kim, SeongJin;Lee, YongKyung;Choi, Jaehyuck;Hong, YoungKi;Kim, JungSung
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.158-164
    • /
    • 2019
  • The interbody fusion cage used to replace the degenerative intervertebral disc is largely composed of titanium-based biomaterials and biopolymer materials such as PEEK. Titanium is characterized by osseointergration and biocompatibility, but it is posed that the phenomenon such as subsidence can occur due to high elastic modulus versus bone. On the other hand, PEEK can control the elastic modulus in a similar to bone, but there is a problem that the osseointegration is limited. The purpose of this study was to implement titanium material's stiffness similar to that of bone by applying cellular structure, which is able to change the stiffness. For this purpose, the cellular structure A (BD, Body Diagonal Shape) and structure B (QP, Quadral Pod Shape) with porosity of 50%, 60%, 70% were proposed and the reinforcement structure was suggested for efficient strength reinforcement and the stiffness of each model was evaluated. As a result, the stiffness was reduced by 69~93% compared with Ti6Al4V ELI material, and the stiffness most similar to cortical bone is calculated with the deviation of about 12% in the BD model with 60% porosity. In this study, the interbody fusion cage made of Ti6Al4V ELI material with stiffness similar to cortical bone was implementing by applying cellular structure. Through this, it is considered that the limitation of the metal biomaterial by the high elastic modulus may be alleviated.

Empirical Study for the Effects of Filler Shape on the Thermal Expansion Coefficient of PP Composites (충전제 함량 및 형태에 따른 PP복합체의 열팽창계수 변화에 대한 실증적 연구)

  • Hwang, Hyo-Yeon;Jeoung, Sun-Kyoung;Shim, Je-Hyeon;Kim, Jae-Min;Lee, Kee-Yoon
    • Polymer(Korea)
    • /
    • v.34 no.4
    • /
    • pp.352-356
    • /
    • 2010
  • The effects of the filler shapes and contents on the coefficient of thermal expansion (CTE) for polypropylene (PP) composites which included three dimensional ellipsoids ($a_1>a_2>a_3$), as determined by two aspect ratios (${\rho}_\alpha=a_1/a_3$ and ${\rho}_\beta=a_1/a_2$) were analyzed by the theoretical approach proposed by Lee and Paul and compared with the experimental results. The shapes of fillers in the composites were various, such as spherical, fiber, disc, and ellipsoid, using barium sulfate, glass fiber, and mica. The longitudinal CTE of barium sulfate whose shape was sphere ($\rho_\alpha=\rho_\beta=1$) decreased. For the glass fiber, primary aspect ratio decreased with the filler content, and longitudinal CTE decreased as filler contents increased. Normal CTE initially increased in the lower filler content. For the mica, longitudinal and transverse CTE decreased but normal CTE increased in the lower filler content like predicted values.

Encystation of Giardia lamblia by High Bile and Alkaline pH and Its Ultrastructural Changes during Encystation

  • Yong, Tai-Soon;Yang, Hye-Won;Im, Kyung-Il;Park, Soon-Jung
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.429-433
    • /
    • 2000
  • Giardia lamblia, a human pathogen causing outbreaks of diarrhea, recently became a focus of great concerns in the fields of both medical and environmental microbioloty. To develop the experimental tools to study giardiasis, encystation, one of the major processes in its life cycle, was reconstituted by inducing an axenic culture of a flagellated form of G. lamblia into a cyst from under high concentration of bile and alkaline pH condition. The successful induction was confirmed by Northern analysis of resulting increased expression of the CWPl gene encoding the cyst wall protein 1. An examination of the encystation process with SEM (scanning electron microscopy) and TEM (transmission electron microscopy) revealed that the trophozoite, a flagellate with a bilateral symmetry, was transformed to a cyst form with an oval-shape and defined filamentous wall. The encystation was found to cause a disappearance of the flagella and an invagination of the adhesive disc. An extensive formation of rER (rough endoplasmic reticulum) was observed after 24h of induction, indication an active synthesis and export of proteins during this process. The vital staining of the invitro-induced systs showed that most cysts maintained their viability.

  • PDF

Injection Molding of Vertebral Fixed Cage Implant

  • Yoo, Kyun Min;Lee, Seok Won;Youn, Jae Ryoun;Yoon, Do Heum;Cho, Yon Eun;Yu, Jae-Pil;Park, Hyung Sang
    • Fibers and Polymers
    • /
    • v.4 no.2
    • /
    • pp.89-96
    • /
    • 2003
  • A vertebral cage is a hollow medical device which is used in spine forgery. By implanting the cage into the spine column, it is possible to restore disc and relieve pressure on the nerve roots. Most cages have been made of titanium alloys but they detract the biocompatibility. Currently PEEK (polyether ether ketone) if applied to various implants because it has good properties like heat resistance, chemical resistance, strength, and especially biocompatibility. A new shape of vertebral cage is designed and injection molding of PEEK is considered for production. Before injection molding of the cage, it is needed to evaluate process conditions and properties of the final product. Variables affecting the shrinkage of the cage are considered, e.g., injection time, packing pressure, mold temperature, and melt temperature. By using the numerical simula-tion program, MOLDFLOW, several cases are studied. Data files obtained by MOLDFLOW analysis are used for stress anal-ysis with ABAQUS, and shrinkage and residual stress fields are predicted. With these results, optimum process conditions are determined.

Origin and meaning of Circular stone Pagoda in Unjusa Temple (운주사 원형석탑의 시원과 의미)

  • Kim, Ki-Yong;Cheon, Deuk-Youm
    • Journal of architectural history
    • /
    • v.23 no.4
    • /
    • pp.91-100
    • /
    • 2014
  • There are lots of and kinds of stone pagoda and stone Buddhas at Unjusa Temple in Hwasun, Jeonnam, which is thus called as Cheontap(千塔) or Cheonbul.(千佛) Several archaeological excavations have been conducted in Unjusa though, the foundation purpose or background motivation is yet wrapped in mystery. Circular shape is representative pagoda of Unjusa made of round frame or spherical roof but circular stone pagoda is unusual that there is no similar example found in India or China as well as in Korea. Located in the symbolic center, Circular stone pagoda is a key to understand Unjusa. Yundeung(輪燈) is made of stone for circular stone pagoda and there are craft lamp and large lamp. The large lamp, for the palace courtyard on the occasion of Palgwanhoe,(八關會) consists of discs and light on each disc. Outdoor lamp of circular stone pagoda made of stone for permanent preservation purpose. Unjusa is a very special temple with stone-yundeung for circular stone pagoda. In this study, a circular stone pagoda that is the source of yundeung said. Unjusa circular stone pagoda next to the title of 'yundeung pagoda' and proposes to call.

A study on flow coefficient evaluation by shape change of butterfly valve (Grooved butterfly valve의 형상 변화에 따른 용량계수 평가에 관한 연구)

  • Lee, Jung-Won;Shin, Bong-Cheol;Cho, Yong-Kyu;Cho, Myeong-Woo;Lee, Kang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.4937-4943
    • /
    • 2012
  • Butterfly valves have been used to control the flow rate of various fluids in many industries because it have unique manageability compare to other valves. The flow rate passing through the butterfly valves can be controlled according to the coefficient of capacity calculated by disk angle change. In this study, flow analysis by 3D modeling was performed to derive the coefficient of capacity to evaluate and improve newly developed butterfly valves. Also, required measurement system was established to verify the performance of the valves, and to compare with the calculated results.

A Study on the One-Stage 3-Dimensional Axial Turbine Performance Test with Different Incidence Angle (입사각 변경에 따른 단단 3차원 축류형 터빈의 성능시험에 관한 연구)

  • 조수용;박찬우
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.2
    • /
    • pp.24-31
    • /
    • 2001
  • An axial-type turbine design technology is developed. In order to design one-stage turbine, the preliminary design method is applied, and then design parameters are chosen after analyzing gas properties within the turbine passage using the streamline curvature method. Stator blade is designed using C4 profile, and rotor blade is designed using shape parameters. Stator is manufactured as an integral type and rotor is manufactured to be disassembled from the disc for changing blade incidence angle. The output power from the rotor is measured with various RPM and input power. Experimental results show that the maximum efficiency of turbine rotor is obtained on the design point, and the output power is proportionally decreased with the negative incidence angle even the test turbine is a reaction turbine. The efficiency of turbine rotor is decreased to 5% by $7.5^{\cire}$ negative incidence angle from the designed value.

  • PDF

Analysis about DITI of the Patients having a Neck and Upper Extremity Pain on One Side (적외선체열촬영을 통한 편측 경항상지통환자의 임상적 고찰)

  • Park, Min-jung;Lee, Kyung-yun;Cho, Won-young;Park, Koae-hwan
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.301-314
    • /
    • 2004
  • Objectives : We studied to discover the patterns of DITI of the patients having a both neck and upper extremity pain on one side without any nerve root compression sign and the history of cervical disc herniation. Method : We selected 26 patients as an experimental group, who had visited for a both neck and upper extremity pain on one side without any nerve root compression sign, at the department of acupunture and moxibustion in Conmaul oriental medical hospital, during 2001. 01. - 2003. 09. And 31 normal adults were selected as a control group, not having any neck or arm pain and any history of cervical disease. We analyzed the segmental temperature statistically with t-test. Results & Conclusion : There was a significant change of temperatures in the scapula, posterior brachium, lateral forearm and dorsal hand area. And the experimental group showed cold spot and disruption of normal thermographic shape that were usually shown on the cervical sprain.

  • PDF

Analysis about DITI of the Patients having a Neck and Upper Extremity Pain on One Side (적외선체열촬영을 통한 편측 경항상지통환자의 임상적 고찰)

  • Lee, Kyung-Yun;Cho, Won-Young;Park, Koae-Hwan;Park, Min-Jung
    • Journal of Oriental Medical Thermology
    • /
    • v.4 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • Objectives : We studied to discover the patterns of DITI of the patients having a both neck and upper extremity pain on one side without any nerve root compression sign and the history of cervical disc herniation. Method : We selected 26 patients as an experimental group, who had visited for a both neck and upper extremity pain on one side without any nerve root compression sign, at the department of acupunture and moxibustion in Conmaul oriental medical hospital, during 2001. 01. - 2003. 09. And 31 normal adults were selected as a control group, not having any neck or arm pain and any history of cervical disease. We analyzed the segmental temperature statistically with t-test. Results & Conclusion : There was a significant change of temperatures in the scapula, posterior brachium, lateral forearm and dorsal hand area. And the experimental group showed cold spot and disruption of normal thermographic shape that were usually shown on the cervical sprain.

  • PDF

Preparation and Properties of Disc Type CuO Catalyst Impregnated Ceramic Filters (디스크형 산화구리 촉매담지 세라믹필터의 제조와 물성)

  • Hong Min-Sun;Moon Su-Ho;Lee Jae-Chun;Lee Dong-Sub;Lim Woo Taik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.185-193
    • /
    • 2004
  • A catalyst with CuO ceramic filter for simultaneous treatment of dust and HAP was prepared and characterized. Catalytic ceramic filter can not only potentially achieve the substantial savings in energy but provide with effective optimization and integration of process for simultaneous removal of SO$_2$, NO$_{x}$ and particulates from flue gases. Catalytic ceramic filters remove simultaneously particulates on exterior surface of filters and reduce NO to $N_2$ and $H_2O$ by SCR (Selective Catalytic Reduction) process. Preparation of catalyst impregnated ceramic filter with disk shape (Ψ 50) follow the processing of alumino-silicate ceramic filter, support impregnation and catalyst impregnation (copper oxide). Preparation routes of alumino-silicate catalyst carrier suitable for production of catalytic filters practically were studied and developed using the sol-gel and colloidal processing, homogeneous precipitation and impregnation method. Characterization of the catalyst, catalyst carrier catalytic filter materials have been performed the using various techniques such as BET, XRD, TGA, SEM. Combination of the sol-gel and colloidal processing and impregnation method is recommended to prepare catalyst carriers economically for catalytic filter applications.s.