• Title/Summary/Keyword: Disaster Prevention Performance

Search Result 345, Processing Time 0.025 seconds

Plan for the Development of a Standardized Dummy for Persons in Need of Rescue in a Confined Space (밀폐공간 구조 요구자를 위한 더미 표준화 개발 방안)

  • Choi, Seo-Yeon;Rie, Dong-Ho;Kim, Hyung-Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.99-105
    • /
    • 2016
  • This study was conducted to develop a dummy in an environment similar to the human body, to prepare a standard for evaluation and to present the process of the production in order to evaluate the performance of the robot that can detect the persons needing rescue in a confined space, who are difficult for fire-fighting officials to rescue in case of fire and disaster. As a result, a standard for evaluation was developed and standardized into four parts 'Normal,' 'Risk Stage 1,' 'Risk Stage 2' and 'Risk Stage 3'based on the number of breath cycles, carbon dioxide concentration, core temperature and criteria for hearing to recognize the voice. In addition, in order to produce a dummy, fever, breathing capacity and voice output function were compared and analyzed. This study has significance that it built up basic data of the method of producing the actual dummy, by presenting characteristics and controlling methods using the waterproof insulation heating coil for the function, solenoid valve for the consecutive output of breathing capacity and USB program sound board for voice output.

Assessing the Suitability of Satellite Precipitation Products for Flood Modeling in the Tonle Sap Lake Basin, Cambodia

  • Oudom Satia Huong;Xuan-Hien Le;Giha Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.176-176
    • /
    • 2023
  • The Tonle Sap is the richest and diverseness of freshwater ecosystem in Southeast Asia, receiving nurturing water flows from the Mekong and its immediate basin. In addition, the rapid development in the Tonle Sap Lake (TSL) Basin, and flood inundation may threaten the natural diversities and characteristics. The impacts of flood inundation in 11 sub-basins contributing to the Tonle Sap Lake were assessed using the Rainfall-Runoff-Inundation (RRI) model to quantify the potential magnitude and extent of the flooding. The RRI model is set up by using gauged rainfall data to simulate the information of river discharge and flood inundation of huge possible flood events. Moreover, two satellite precipitation products (SPPs), CHIRPS and GSMaP, within respectively spatial resolutions of 0.05° and 0.1°, are utilized as an input for the RRI model to simulate river discharge, flood depth, and flood extent for the great TSL Basin of Cambodia. This study used statistical indicators such as NSE, PBIAS, RSR, and R2 as crucial indices to evaluate the performance of the RRI model. Therefore, the findings of this study could provide promising guidance in hydrological modeling and the significant implications for flood risk management and disaster preparedness in the region.

  • PDF

Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes (방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안)

  • Hong-Sang Lee;Jai Young Lee;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.

An Exploratory Study on the Analysis of Characteristics of Pedestrian Accident Vulnerable Points using Road View: Focusing on Sasang-gu, Busan (로드뷰를 활용한 보행자 사고 취약 지점 특징 분석 탐색적 연구: 부산광역시 사상구를 중심으로)

  • Dong Kyu Lee;Jae Seon Kim;Kyung Soo Pyo;Min Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.351-368
    • /
    • 2024
  • Purpose: In general, traffic accidents occur sporadically, so there are various limitations in terms of time and cost when conducting field investigations to prepare prevention and prevention measures. In particular, with the transition to a non-face-to-face society after the COVID-19, there is a greater need to prepare a replacement for field surveys. Therefore, in this study, Roadview provided by various websites was used as an alternative to field surveys in Sasang-gu, Busan City. The possibility was evaluated. Method: The research method was to extract vulnerable points for traffic accidents that occurred between 2016 and 22 and analyze road views based on the field survey evaluation items provided in the Traffic Safety Diagnosis Guidelines. Result: The main result was that Sasang-gu was most vulnerable to accidents involving elderly pedestrians at Sasang-ro, Daedong-ro, and Hakjang-ro. As a result of a detailed analysis of vulnerable points through Road View, Sasang-ro needed control of commercial vehicles and protection of the transportation vulnerable in the market commercial area. Daedong-ro was vulnerable to illegal on-street parking and slope merging sections, and Hakjang-ro was vulnerable to roads that were prone to speeding. When evaluating the possibility of replacing Roadview's field survey based on the results of this analysis, Roadview was able to effectively evaluate most items, such as separation of sidewalks and the location and spacing of safety facilities. However, there were limitations in items such as actual measurement performance. Conclusion: In other words, the road view can replace most field surveys, and the actual measurement evaluation items can be judged to be useful as auxiliary data, resulting in time and cost savings and high efficiency.

A Study on the Performance and the Improving Methods of the Building Fire Compartment under the Domestic Fire Safety Regulations (국내 방화규정에 따른 건축물 방화구획 성능 및 개선방안에 관한 연구)

  • Chun, Woo-Young;Lee, Kwang-Won;Lee, Ji-Hee;Kim, Wha-Jung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.19-24
    • /
    • 2008
  • Recently, the buildings have gradually become higher, more massive and more complex with high growth of economy and varieties of the patterns of people's living. Therefore we study a performance and Improving Methods of the fire compartment as a measure to minimize the damage of the people and property from the fire. Currently, under the economic crisis situation, we do not consider about prevention of disaster safety enough; safety investment evasion, safety carelessness, and management relaxation etc. Also in the aspect of regulation system, industrial technology and plan engineering, Korean techniques of preventing fire disasters are far behind of other advanced nations. At this point, we are in need of improving about it. When considering like this situation, we need more studies on the practical improvement in order to assure fire prevention for buildings. The fire compartment prevent from magnifying the fire to the wide area by compartment into specific area. From this, it is possible to minimize fire damage and property and secure emergency exit for life safety. This fire compartment has primary function to extinguish fire easily, and the openings and penetrations are important passage which makes the smoke and fire go away from the fire area to the contiguous space. This study suggests improving methods of domestic fire compartment efficiency standard through comparative analysis of overseas advanced provision and domestic provision about base element of the building fire prevention.

  • PDF

An Analysis of Vulnerabilities and Performance on the CCTV Security Monitoring and Control (CCTV 보안관제 취약성 및 성능 분석)

  • Seo, Tae-Woong;Lee, Sung-Ryoul;Bae, Byung-Chul;Yoon, E-Joong;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.1
    • /
    • pp.93-100
    • /
    • 2012
  • Recently, the security monitoring and control systems based on spatial information in various field are operated and being developed according to evolve the spatial information technology. Especially, the CCTV monitoring and control system can be used in various field as a typical system. However, the security vulnerability problems have become an issue because the system connected by computer network and getting bigger than before. Therefore we studied security vulnerabilities of CCTV monitoring and control system which is being developed and operated. In addition, it is important to consider disaster and terrorism with unauthorized changes on location information. Therefore we analyzed the performance of observation when the cameras are break down as a result by hacking to CCTV monitoring and control system.

A Study on the Recording Technology of Fire Propagation Prevention Wall Using Horticultural Plants (원예식물을 식재한 화재확산 방지용 벽면녹화 기술연구)

  • Moon, Jong-Wook;Lim, Seo-Hyung
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.107-114
    • /
    • 2018
  • Purpose : This study is to develop walls using wall recording technology applied on roofs to prevent fire spread in traditional markets. Method : The spray head installed on the developed wall was designed so that the fire does not spread to adjacent buildings after being used for plants. In addition, a spray head was attached to the upper section and some sections for the growth of plants planted on the wall to prevent the spread of fire. Results : These technologies suggested the development of walls that can be installed at the upper level of buildings, such as traditional markets, and separate isolation facilities were not necessary because they are integrated with structures and sprinklers. In addition, sprinklers can perform both the plant spray and fire spread prevention functions. It is believed that this is the only alternative technology proposed in Korea to prevent the spread of fire. Conclusion : In this study, the wall design, designed directly to derive the quantitative performance of the fire spread reduction effect, demonstrated the fire suppression method of the wall system, the durability of the wall itself, and the flame retardability performance.

Evaluation of the Prediction Performance of FDS Combustion Models for the CO Concentration of Gas Fires in a Compartment (구획실 내 가스연료 화재의 CO 농도에 대한 FDS 연소모델의 예측성능 평가)

  • Baek, Bitna;Oh, Chang Bo;Hwang, Chel-Hong;Yun, Hong-Seok
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The prediction performance of combustion models in the Fire Dynamics Simulator (FDS) were evaluated by comparing with experiment for compartment propane gas fires. The mixture fraction model in the FDS v5.5.3 and Eddy Dissipation Concept (EDC) model in the FDS v6.6.3 were adopted in the simulations. Four chemical reaction mechanisms, such as 1-step Mixing Controlled, 2-step Mixing Controlled, 3-step Mixing Controlled and 3-step Mixed (Mixing Controlled + finite chemical reactions) reactions, were implemented in the EDC model. The simulation results with each combustion model showed similar level for the temperature inside the compartment. The prediction performance of FDS with each combustion model showed significant differences for the CO concentration while no distinguished differences were identified for the $O_2$ and $CO_2$ concentrations. The EDC 3-step Mixing Controlled largely over-predicted the CO concentration obtained by experiment and the mixture fraction model under-predicted the experiment slightly. The EDC 3-step Mixed showed the best prediction performance for the CO concentration and the EDC 2-step Mixing Controlled also predicted the CO concentration reasonably. The EDC 1-step Mixing Controlled significantly under-predict the experimental CO concentration when the previously suggested CO yield was adopted. The FDS simulation with the EDC 1-step Mixing Controlled showed difficulties in predicting the $CO_2$ concentration when the CO yield was modified to predict the CO concentration reasonably.

Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling (화재모델링 예측성능 개선을 위한 이온화식 연기감지기의 장치물성 측정)

  • Kim, Kyung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2013
  • The high prediction performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of PBD (Performance Based fire safety Design). The main objective of the present study is to measure input information in order to predict the accurate activation time of smoke detector into a Large Eddy Simulation (LES) fire model such as FDS (Fire Dynamics Simulator). To end this, FDE (Fire Detector Evaluator) which can measure the device properties of detector was developed, and the input information of Heskestad and Cleary's models was measured for a ionization smoke detector. In addition, the activation times of smoke detectors predicted using default values into FDS and measured values in the present study were systematically compared. As a result, the device properties of smoke detector examined in the present study showed a significant difference compared to the default values used into FDS, which resulted in the considerable difference of up to 15 minutes or more in terms of the activation time of smoke detector. The database (DB) on device properties of various smoke and heat detectors will be built to improve the reliability of PBD in future studies.

Time-dependent Performance-based Design of Caisson Breakwater Considering Climate Change Impacts (기후변화 효과를 고려한 케이슨 방파제의 시간 의존 성능설계)

  • Suh, Kyung-Duck;Kim, Seung-Woo;Mori, Nobuhito;Mase, Hajime
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.3
    • /
    • pp.215-225
    • /
    • 2011
  • During the past decade, the performance-based design method of caisson breakwaters has been developed, which allows a certain damage while maintaining the function of the structure. However, the existing method does not consider the changing coastal environment due to climate change impacts so that the stability of the structure is not guaranteed over the lifetime of the structure. In this paper, a time-dependent performance-based design method is developed, which is able to estimate the expected sliding distance and the probability of failure of a caisson breakwater considering the influence of sea level rise and wave height increase due to climate change. Especially, time-dependent probability of failure is calculated by considering the sea level rise and wave height increase as a function of time. The developed method was applied to the East Breakwater of the Hitachinaka Port which is located on the east coast of Japan. It was shown that the influence of wave height increase is much greater than that of sea level rise, because the magnitude of sea level rise is negligibly small compared with the water depth at the breakwater site. Moreover, investigation was made for the change of caisson width due to climate change impacts, which is the main concern of harbor engineers. The longer the structure lifetime, the greater was the increase of caisson width. The required increase of caisson width of the Hitachinaka breakwater whose width is 22 m at present was about 0.5 m and 1.5 m respectively for parabolic and linear wave height increase due to climate change.