• Title/Summary/Keyword: Disaster Management Manual

Search Result 92, Processing Time 0.022 seconds

A study on the effect of gusty wind on smoke control performance in road tunnel (돌풍이 도로터널의 제연성능에 미치는 영향 연구)

  • Baek, Doo-San;Cho, Hyeon-Seok;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.95-108
    • /
    • 2022
  • The increase in the use time of tunnel users due to the lengthening of the road tunnel may increase the evacuation time in case of fire, resulting in a large number of casualties. In order to reduce the casualties caused by fire, the "Road Tunnel Design Manual, Part 6 Tunnel" and "Road Tunnel Disaster Prevention Facility Installation and Management Guidelines" stipulate that ventilation facilities should be installed along with the extension of the tunnel. The ventilation system design factor considers the wind speed of the external natural wind to be at least 2.5 m/s, and it is applied upward according to the characteristics of the tunnel. As a result of analyzing the five-minute average wind speed data in the Daegwallyeong region for the past 6 years, it was analyzed that 15.8% of the windy days were winds of 10 m/s or more, and the maximum was 20 m/s. Therefore, in this study, when a fire occurs in a tunnel, the pattern of natural wind flowing into the tunnel and the backlayering distance of the tunnel fire smoke according to the maximum wind speed were analyzed. As a result, it was analyzed that a backflow of up to 490 m occurs when a gust of 20 m/s blows.

Case Study of Immersed Tunnel Instrumentation Management Using Wireless System (지중무선 시스템을 이용한 침매터널 구간 계측관리 사례연구)

  • Han, Sang-Wook;Kim, Byung-Hee;Han, Byung-Won;Lee, Gye-Chun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.768-773
    • /
    • 2009
  • Measuring method being applied for off-shore works is performed by using data logger or manual measuring instrument with wiring the cable connected from the sensor up to the position where measuring is allowed.(upper part of embankment or marine structure) Measuring management by using existing measuring method may be acceptable on the condition that the ground deformation volume(vertical, horizontal) is generally minimal and the site condition is good. But loss of measuring instrument, sensor cable failure or cutting is taken place frequently due to significant change of ground behavior caused by an external force change(embankment, excavation) under very soft ground condition(N value below 0-4). In case of the marine works, in particular, loss rate of measuring instrument is highly represented due to the factors of working barge anchoring, constructional interference and natural disaster. In order to solve these problems, measuring management was performed with employing underground wireless system at the immersed tunnel site. Measuring data was obtained freely under the marine environment by using underground wireless communication and cable cutting potential by ground behavior could be reduced. Measuring cost savings and its installation convenience were maximized by way of off-shore tower installation or cabling and by minimizing constructional interference of off-shore working barge. This case of measuring management was accomplished successfully.

  • PDF

A Study on the Causes and Improvement Plans for Firefighters' Casualty Accidents During Rescue Activities related to the Water - 4M Analysis - (수난구조활동 중 소방공무원 순직사고의 원인과 대응방안에 관한 연구 - 4M분석기법을 중심으로 -)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.710-721
    • /
    • 2021
  • Purpose: The purpose of this study is to prepare an environment that can provide high-quality 119 rescue services by analyzing the causes of casualties at the water rescue and suggesting improvement plans to prevent them. Method: 5 major cases were analyzed among firefighters' casualty accidents during rescue activities related to the water over the past 10 years for case study. And the causes of the accidents were analyzed in terms of 4 values (Man, Machine, Media, Management) through the 4M analysis technique. Result: ① man: the main causes are lack of awareness of on-site safety, etc ② machine: the problem of the absence of the equipment itself, etc ③ media: the lack of information on the rescue site and the poor rescue environment conditions, ④ management : the main causes were the absence and inadequacy of the response manual for each rescue site, Conclusion: ① man: knowledge of SOP and reinforcement of education and training, etc. ② machine: there are measures such as the introduction of equipment suitable for the changing rescue site, ③media: providing sufficient information about the rescue activity environment and conducting regular road training, ④ management: policy suggestions such as establishment and dissemination of on-site safety management plans and manuals were derived.

Development of Infrastructure automatic alert populating system in Geotechincal Monitoring field (지반 분야에서의 시설물 안전위험 자동화 상황전파 시스템 개발)

  • Jung, Jea-Hyen;Kim, Yong-Su;Han, Sang-Jea
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.933-939
    • /
    • 2010
  • Gathering information and systemization of infrastructure disaster management is to reduce uncertainties in making decisions and maximize the number of alternations for reasonable decision making. The key object is the progress report & propagation automation system based on sensors, which is major for providing objective data to realize and support decision makings and delivering decision to a certain area, department, manager and other people rapidly. Collecting, reviewing and database of existing progress report & propagation manual in order to achieve networking of safety management on major social infrastructure of the nation, materialization of field-oriented intelligent business process by developing mobile safety management command transmission device and integrating it into facility safety management network.

  • PDF

COVID-19 Related Personal Information Issues and Countermeasures from the Perspective of Record Management (기록관리 관점에서 본 코로나 19 관련 개인정보 이슈와 대응방안)

  • Jeong, Ji-Hye;Na, Jeong-Ho;Jang, Ji-Hye;Oh, Hyo-Jung
    • Journal of the Korean Society for information Management
    • /
    • v.37 no.4
    • /
    • pp.81-107
    • /
    • 2020
  • At a time when Korea and the rest of the world recently faced the unprecedented situation of "COVID-19," the view of actively "disclosure" of information to prevent the spread of infectious diseases is at odds with the view of "protecting" personal information as these social measures are coupled with the infringement of individuals' basic rights. In order to see the nation's response to the infectious disease crisis, we examined the current status and characteristics of public records according to crisis alert levels based on the manual for responding to infectious disease. Especially we analyzed the types and disclosure status of records containing personal information. For detecting personal information-related issues on news media, we collected online news articles and performed text anlaysis. Through this, we reviewed the problems of record management including personal information and suggested improvement points from the perspective of the life cycle of records: collect, manage, and dispose of them.

A Study on the improvement for response manual of chemical terror incident using the service design analysis (서비스디자인 접근법을 활용한 화학테러현장 대응매뉴얼의 개선방안 연구)

  • Ham, Seung Hee;Park, Namkwun;Lee, Jun
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.325-333
    • /
    • 2018
  • Purpose: There have been terrorist attacks all over the world, causing massive damage. In Korea, there are few cases of terrorist damage, but the lack of the on-site response experience lead to constraints on the opportunity to verify capabilities against terrorism. Therefore, in this study, the chemical terrorism on-site countermeasures is considered as a concept of service, it was possible to draw up improvement alternatives for each element by reviewing at once the interactions between the concerned organizations and citizens in the field and the utilization of the equipment and facilities in the invisible area. Results: It had been evaluated the service process of the counterpart manager from the viewpoint of the victim citizen, who is the beneficiary of the final security service. It has found out the waiting point(W.P) between the victim's civilian incident management, and the element of failure(F.P). Conclusion: In this way, comparing chemical terror incident response manuals belonged to each related organization by fusion of service design approach and scenario technique, It is expected that it will be able to find out more specific problems and to find improvement alternatives.

Propose an Improvement of Checklist for Actual Condition Survey for Designation of Class-lll Facilitie (제3종시설물 지정을 위한 실태조사 체크리스트 개선방안)

  • Yoon, Ji-Ho;Jang, Myunghoun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.100-101
    • /
    • 2021
  • Facilities with high risk of a disaster or requiring continuous safety management are designated as class-III facility. In order to designate a class-III facility, it is evaluated based on the safety status of the facility, the risk to the building users, and the number of years elapsed of the facility, etc. and this shall be referred to the actual condition survey for the designation of a class-III facility. In the actual condition survey conducted to designate the safety status is calculated by the checklist based on the evaluation scores consisting of five stages each item, and is evaluated in three stages by 'good', 'careful observation', and 'designated review' through the average of the combined scores. Currently, the actual condition survey being conducted applies only structural stability, and the risk factors such as damage to the finish, the risk of cracking, and the type and weight of major structures are not included in the checklist for the actual condition survey, so even if experts think it is dangerous, scores cannot be reflected. Therefore, this study aims to analyze the problems of checklist of the actual condition survey for the designation of class-III facility and to propose an improvement plan for the checklist for the actual condition survey.

  • PDF

Policy Plans for the Maintenance of Public Security of Living During the War (전시 국민생활안정 유지방안)

  • Kil, Byung-Ok
    • Journal of National Security and Military Science
    • /
    • s.5
    • /
    • pp.131-172
    • /
    • 2007
  • Government duties in the cases of crisis are aimed at supporting efficient military operations in the fields of non-military affairs and resource mobilization, maintenance of government functions, and search for the public security of living during the war. In crisis, the government must change its functions into the total-war system with all resources available for the efficient performance of military operations, war economy, public safety and security as well as government continuance. The main contents of "Chung-Mu Plan" include the alternative measures to control the circulation of life necessities, emergency electricity, water and gas; recover public facilities from the disaster; and accommodate the wounded and refugees. Governments have practiced Ul-chi and ChungMoo exercises to improve government's management capabilities and master standard operating procedures including systematic distribution plans in the national and local level. However, such plans have not yet sufficient enough for the maintenance of public security of living. In addition to the conceptual ambiguity, major problems are the inappropriate system of the war economy, legal institutions, and administrative SOPs for the efficient maintenance of it. Thus, for the betterment of national crisis management system, the government should have the manual stated from every step and level dealing with crisis to the legal institutions. It is important to empower the National Emergency Planning Commission for the policy consistency and efficient/effective implementation. The comprehensive plans must have an integrated cooperative system of the central/local governments, military and civil society with actual practices and exercises for the maintenance of the public security of living.

  • PDF

A Study on the Fire Hazard of Transportation Oil (수송기관용 오일의 화재위험성에 관한 연구)

  • Park, Young Ju;Hwang, Me Jung;Lee, Hae Pyeong;Lee, Seung Chul;Lee, Chang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.114-120
    • /
    • 2014
  • The purpose of this study is to conduct the study of the combustion and thermal characteristics through transportation oil for the analysis of fire hazard. Transportation oil breaks down into fuels such as diesel for civilian demands, gasoline, DF1(diesel for military), high sulfur diesel(for marine), kerosene and JP1(for aviation), and lubricants like brake fluid, power steering oil, engine oil, and automatic and manual transmission oil. The experiments of flash point, ignition point, flame duration time, heat release rate were carried out using TAG closed cup flash point tester(AFP761), Cleveland open cup auto flash point analyzer(AFP762), KRS-RG-9000 and Dual cone calorimeter. As a result, the fuel's ignition points were lower than lubricants, especially that of gasoline was not conducted as it has below zero one. Gasoline has the highest ignition point of about $600^{\circ}C$, while the other fuels showed $400{\sim}465^{\circ}C$. For flame duration time, lubricants had over 300 seconds, but fuels had less than 300 seconds except high sulfur diesel(350 seconds). Total heat release rate ranged $287{\sim}462kW/m^2$ for lubricants and gasoline showed the highest total heat release rate, $652kW/m^2$.

Heart Rate Strain of Forest-workers in Timber Harvesting Operation (심박수를 이용한 임목수확작업의 작업강도 분석)

  • Baek, Seung-An;Lee, Eun-Jai;Nam, Ki-Hun;Cho, Koo-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.593-601
    • /
    • 2020
  • This study was conducted to analyze the physical strain with heart rate monitor in timber harvesting operations in order to reduce occupational accidents. The timber harvesting activities are manual cutting(felling, limbing and bucking) with a chainsaw and extraction by cable yarder. The study took place on Japanese larch stand. The average height was 26m and average diameter at breast height(DBH) was 3 7cm. The havest unit was gentle slope to steep slope. Results showed that the heart rate increases for chocking, felling, limbing and bucking were 94.0%, 87.9%, 84.8% and 56.4% respectively. The rate of Work Load Index was higher in the limbing(61.4%) activity than other activities chocking(55.2%), felling(54.1%) and bucking(32.1%). During 50% working heart rate test it was found that limbing(1.09), chocking(1.05) and felling(1.04) was exposed to high work intensity compared to bucking(0.83). The results showed that maximum acceptable work times(felling, chocking and limbing) were 2.30 hour, 1.85 hour and 1.60 hour respectively. To avoid occupational accidents, timber harvest workers may use a suitable working hour schedule to felling, chocking, limbing.