• Title/Summary/Keyword: Direct detection

Search Result 920, Processing Time 0.025 seconds

Experimental Studies on Detection of Salmonellae in Animal-origin Foods by Means of Dirct Fluorescent Antibody Technique (직접형광항체법(直接螢光抗體法)에 의한 축산식품중(畜産食品中)의 Salmonella 균(菌) 검출(檢出)에 관한 실험적(實驗的) 연구(硏究))

  • Jeon, Moo Hyeong;Cha, Youn Ho;Chung, Gill Taik
    • Korean Journal of Veterinary Research
    • /
    • v.14 no.2
    • /
    • pp.243-252
    • /
    • 1974
  • The experiment was performed in order to investigate the applicability of the rapid detection of salmonellae in various animal-origin foods by means of the direct fluorescent antibody technique. Egg, sausage and chicken were inoculated with various concentrations of Sal.paratuphi A, Sal. paratyhi B and Sal. thompson, and the fluorescent antibody technique was applied and compared with the conventional cultura method for the sensitivity of detection of the organisms. Two methods were employed in the fluorescent antibody technique; the direct smear method in which the smear being made directly from the specimens, and the enrichment smear method in which the smear being made from the enrichment broth. The effect of various enrichment time (1,5,8,11 and 13 hours) in tetrathionate broth on the detection of salmonellae in the fluoresent antibody technique was also studied. The results obtained were summarized as followings; 1. Of the three methods, the enrichment smear method of fluorescedt antibody technique was highly effective as cultural method for the detection of salmonella organisms. 2. Direct smear method of fluorescent antibody technique was effective as two other methods $5{\times}10^4$ organisms presented in 50 g(ml) of specimens. This method may not be applicable when the specimens contained $5{\times}10^2$ or less organisms. 3. Of the three specimens, the recovery rate of Salmonella organisms from egg was slightly higher than that of sausage and chicken. 4. In fluorescent antibody technique and cultural method, the specimens inoculated with Sal. thompson were found to be higher detection rate than the specimens inoculated with Sal. paratyphi A, 5. The optimum enrichment time of Salmonella organisms in tetrathionate broth on the detection by fluorscent antibody technique was found to be 11 hours or longer when the specimens of egg, sausage and chicken were inoculated with approximately 500 organisms. The longer enrichment time was the higher detection rate up to 11 hours tested.

  • PDF

Direct Multiplex Reverse Transcription-Nested PCR Detection of Influenza Viruses Without RNA Purification

  • Song, Man-Ki;Chang, Jun;Hong, Yeong-Jin;Hong, Sung-Hoi;Kim, Suhng-Wook
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.11
    • /
    • pp.1470-1474
    • /
    • 2009
  • This paper describes the development a of direct multiplex reverse transcription-nested polymerase chain reaction (PCR) method, devised for simultaneous detection and typing of influenza viruses. This method combines the direct reverse transcription reaction without RNA purification with the enhancement of sensitivity and specificity of nested PCR. The method successfully detected three major human influenza viruses: influenza virus A subtype 1 (H1N1) and subtype 3 (H3N2), and influenza B virus (B). The minimum number of virus particles (pfu/ml) necessary for detection in spiked saliva samples was 200 (H1N1), 140 (H3N2), and 4.5 (B). The method's sensitivity and simplicity will be convenient for use in clinical laboratories for the detection and subtyping of influenza and possibly other RNA viruses.

Comparison Study of Long-haul 100-Gb/s DDO-OFDM and CO-OFDM WDM Systems

  • Liu, Ling;Xiao, Shilin;Bi, Meihua;Zhang, Lu
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.557-562
    • /
    • 2016
  • In this paper, for the first time, the transmission performances of long-haul 100-Gb/s direct detection optical OFDM (DDO-OFDM) and coherent optical OFDM (CO-OFDM) wavelength division multiplexing (WDM) systems are compared by simulation. It provides specific guides for system parameter selection to get a high-performance and cost-effective OFDM WDM system. Specifically, the comparison involves three aspects: launched power is investigated to achieve better system performance; laser linewidth is numerically investigated to choose cost-effective laser; system dispersion tolerances with different laser linewidths are analyzed to further reveal the advantages and disadvantages of these two detecting methods, direct detection and coherent detection, in long-haul OFDM WDM system.

Detection and localization of partial discharge in high-voltage direct current cables using a high-frequency current transformer (HFCT를 활용한 고전압직류송전 케이블 부분방전 위치추정)

  • Hong, Seonmin;Son, Wooyoung;Cheon, Hyewon;Kang, Daekyoung;Park, Jonghoo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.105-108
    • /
    • 2021
  • Detection and localization of partial discharge are considered critical techniques for estimating the lifetimes of power cables. High-frequency current transformers (HFCTs) are commonly used for the detection of partial discharge in high-voltage alternating current (HVAC) power cables; however, their applicability is compromised by the limitations of the installation locations. HFCTs are typically installed in cable terminals or insulation joint boxes because HVACs induce strong time-varying magnetic fields around the cables, saturating the ferromagnetic materials in the HFCTs. Therefore, partial discharges near the installation locations can be detected. In this study, the feasibility of partial discharge detection using a HFCT was investigated for high-voltage direct current (HVDC) cables. We demonstrated that the HFCT could be installed at any location in the HVDC power cable to monitor partial discharge along the entire cable length. Furthermore, we showed that the HFCT could detect the location of partial discharge with high accuracy.

Super-High Speed Photo detection through Frequency Conversion for Microwave on Optical Network

  • Choi, Young-Kyu;Shin, Sang-Yeol
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.439-443
    • /
    • 2008
  • It is shown that even if the modulating frequency of the light is too high for direct detection the signal can be extracted by frequency conversion at the same time as the detection by means of the nonlinearity of the APD. When this frequency conversion detection is applied to an optical receiver, the detection bandwidth can be increased while the configuration of the optical detection circuit and the signal processing in the subsequent stages are simplified. A fundamental analysis is carried out with an APD which is confirmed experimentally.

The chemical reactivity of detecting tube detection equipment for incident responder (화학사고 초기대응자를 위한 검지관식 탐지장비의 반응성 연구)

  • Ahn, Seung-Young;Kim, Jungmin;Kim, Sungbum;Chun, Kwangsoo;Lee, Jin-Seon;Park, Choonhwa
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2014
  • Chemical accidents are the cause of the accident site during the initial responders to quickly and easily see materials and concentration method for the U.S. Environmental Protection Agency(EPA) is widely used in the initial response team direct reading detection equipment used. Ministry of the tubular gas detection equipment to detect direct reading detection equipment used in the event of an accident scene, and shell-and-tube gas detector for rapid detection and identification and precise analysis of causative pollutants before about strategically can identify the quantitative and qualitative useful equipment. However, those who initially respond to the scene of a direct reading detection equipment and a simple lack of understanding of how to use the numbers only because of the way you want to check the accuracy of detection results have been raising questions about the increase. The scene of the accident in order to obtain an accurate detection results used in this paper, the Ministry of Environment of gas detectors detect tubular Kitagawa and Draeger detector tube to check the reactivity of the material on-site detection of early response of those who were to raise the accuracy of the results.

Self-Encoded Spread Spectrum with Iterative Detection under Pulsed-Noise Jamming

  • Duraisamy, Poomathi;Nguyen, Lim
    • Journal of Communications and Networks
    • /
    • v.15 no.3
    • /
    • pp.276-282
    • /
    • 2013
  • Self-encoded spread spectrum (SESS) is a novel modulation technique that acquires its spreading code from a random information source, rather than using the traditional pseudo-random noise (PN) codes. In this paper, we present our study of the SESS system performance under pulsed-noise jamming and show that iterative detection can significantly improve the bit error rate (BER) performance. The jamming performance of the SESS with correlation detection is verified to be similar to that of the conventional direct sequence spread spectrum (DSSS) system. On the other hand, the time diversity detection of the SESS can completely mitigate the effect of jamming by exploiting the inherent temporal diversity of the SESS system. Furthermore, iterative detection with multiple iterations can not only eliminate the jamming completely but also achieve a gain of approximately 1 dB at $10^{-3}$ BER as compared with the binary phase shift keying (BPSK) system under additive white gaussian noise (AWGN) by effectively combining the correlation and time diversity detections.

A new perspective towards the development of robust data-driven intrusion detection for industrial control systems

  • Ayodeji, Abiodun;Liu, Yong-kuo;Chao, Nan;Yang, Li-qun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2687-2698
    • /
    • 2020
  • Most of the machine learning-based intrusion detection tools developed for Industrial Control Systems (ICS) are trained on network packet captures, and they rely on monitoring network layer traffic alone for intrusion detection. This approach produces weak intrusion detection systems, as ICS cyber-attacks have a real and significant impact on the process variables. A limited number of researchers consider integrating process measurements. However, in complex systems, process variable changes could result from different combinations of abnormal occurrences. This paper examines recent advances in intrusion detection algorithms, their limitations, challenges and the status of their application in critical infrastructures. We also introduce the discussion on the similarities and conflicts observed in the development of machine learning tools and techniques for fault diagnosis and cybersecurity in the protection of complex systems and the need to establish a clear difference between them. As a case study, we discuss special characteristics in nuclear power control systems and the factors that constraint the direct integration of security algorithms. Moreover, we discuss data reliability issues and present references and direct URL to recent open-source data repositories to aid researchers in developing data-driven ICS intrusion detection systems.

MULTIPLE OUTLIER DETECTION IN LOGISTIC REGRESSION BY USING INFLUENCE MATRIX

  • Lee, Gwi-Hyun;Park, Sung-Hyun
    • Journal of the Korean Statistical Society
    • /
    • v.36 no.4
    • /
    • pp.457-469
    • /
    • 2007
  • Many procedures are available to identify a single outlier or an isolated influential point in linear regression and logistic regression. But the detection of influential points or multiple outliers is more difficult, owing to masking and swamping problems. The multiple outlier detection methods for logistic regression have not been studied from the points of direct procedure yet. In this paper we consider the direct methods for logistic regression by extending the $Pe\tilde{n}a$ and Yohai (1995) influence matrix algorithm. We define the influence matrix in logistic regression by using Cook's distance in logistic regression, and test multiple outliers by using the mean shift model. To show accuracy of the proposed multiple outlier detection algorithm, we simulate artificial data including multiple outliers with masking and swamping.

Analysis of Performance employing Chromatic Dispersion in Millimeter-wave Links (밀리미터파 대역 링크에서 색 분산에 의한 성능 분석)

  • 김정태
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.309-312
    • /
    • 2000
  • In this paper, The Influence of chromatic fiber dispersion on the transmission distance of MMW(millimeter-wave) link is analyzed and discussed. It is shown that dispersion significantly limits the transmission distance in intensity modulated direct detection and heterodyne links operating in the above 20㎓ frequency region by inducing a carrier to noise penalty on the transmitted signal. We analyze and discuss the influence of dispersion induced CNR(Carrier to Noise Ratio) penalty for direct detection and heterodyne method from simulation.

  • PDF