• Title/Summary/Keyword: Direct casting method

Search Result 54, Processing Time 0.03 seconds

The Movement Characteristics of Suspended Solid(SS) in Harbor Construction(II) - The Landfill Construction and The Grab Dredging Construction (항만공사시 부유토사의 거동 특성에 관한 연구(II) - 매립 및 준설공사시 -)

  • Lee Ji Wang;Maeng Jun Ho;Cho Kwang Woo;Yang Gwon Weol;Kim Young Seup
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.2
    • /
    • pp.46-53
    • /
    • 2003
  • In order to analyze the movement characteristics of suspended solid(SS) in harbor construction, we investigate the generation and movement processes of the SS for the landfill construction by direct casting method and the grab dredging construction which is the most frequent process in harbor construction. We find that the SS is generated into a very high concentration right after the direct casting of landfill soil and continued up to 60 minutes in the landfill construction using the direct casting method with dredged materials by a ship of 700-tonnage. In the grab dredging construction, the SS is generated in a high density of concentration near at its source regardless of water depth, formed belt and diffused up to 700m along the trajectory of tidal current. Based on the result of the present study, it is recommended for the mitigation of SS generation that the silt protector be deployed near at construction site close enough to block the diffusion of SS and the body length of silt protector be long enough to mitigate the SS diffusion in the bottom layer.

  • PDF

A Study on Analysis Method of Tap-Offs for CATV/DBS/CS by Even.Odd-Mode Theory (CATV/DBS/CS용 신호분기기의 우.기 모드 해석법)

  • 김동일;황재현;류현욱;하도훈;정세모
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.346-351
    • /
    • 2001
  • A new analysis method was proposed, where the even . odd-mode theory for a symmetrical coupled-line directional coupler was applied to a transformer-type directional coupler. In addition, the tap-offs were analyzed by the proposed theory, which are widely used in CATV (Cable Television), DBS (Direct Broad- casting Satellite), CS (Communication Satellite) systems. By comparing the calculation results to the measured ones using the even . odd-mode reflection coefficients only, the validity of the proposed analysis method was confirmed. Then, the tap-off has been broadened from 5 MHz over 4,000 MHz by adopting the proposed theory.

  • PDF

Preparation and Characterization of MWCNT-g-Poly (Aniline-co-DABSA)/Nafion® Nanocomposite Membranes for Direct Methanol Fuel Cells

  • Abu Sayeed, Md.;Kim, Young Ho;Kim, Chorong;Park, Younjin;Gopalan, A.I.;Lee, Kwang-Pill;Choi, Sang-June
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2657-2662
    • /
    • 2013
  • Multiwalled carbon nanotube (MWCNT)-g-poly (aniline-co-2,5-diaminobenzenesulfonic acid) (DABSA) reinforced Nafion$^{(R)}$ nanocomposite membranes were prepared and characterized for direct methanol fuel cells (DMFCs). The nanocomposite membranes with approximately $90{\mu}m$ thickness were prepared by the water assisted solution casting method. To evaluate the properties of nanocomposite membranes for DMFC applications, the nanocomposite membranes were characterized by methanol and water uptake, thermal stability, and ion exchange capacity (IEC). Furthermore, oxidative stability measurements in terms of the hydrogen peroxide decomposition rate that represent the oxidative stability of the membranes were examined. The methanol uptake values of the nanocomposite membranes were dramatically decreased compared to the cast Nafion$^{(R)}$ membranes. The IEC values of the nanocomposite membranes were increased about 30% compared to the cast Nafion$^{(R)}$ membrane.

Numerical Modeling of Heat Transfer for Squeeze Casting of MMCs (용탕주조법을 이용한 금속복합재료 제조공정의 열전달 해석)

  • Jung, C.K.;Pyun, H.J.;Jung, S.W.;Nam, H.W.;Han, K.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.319-324
    • /
    • 2001
  • A finite element model for the process of squeeze casting for metal matrix composites (MMCs) in cylindrical mold is developed. The fluid flow and the heat transfer are the fundamental phenomena in the squeeze casing process. To describe heat transfer with solidification of molten aluminum, the energy equation in terms of temperature and enthalpy are applied to two dimensional axisymmetric model which is similar to the experimental system. And one dimensional flow model is employed to simulate the transient metal flow. The direct iteration technique was used to solve the resulting nonlinear algebraic equations. A computer program is developed to calculate the enthalpy, temperature and fluid velocity. Cooling curves and temperature distribution during infiltration and solidification are calculated for pure aluminum. The temperature is measured and recorded experimentally. At two points of the perform inside and one point of the mold outside, thermocouple wire are installed. The time-temperature data are compared with the calculated cooling curves. The experimental results show that the finite element model can estimate the solidification time and predict the cooling process.

  • PDF

Visualizing the Peripheral Primo Vascular System in Mice Skin by Using the Polymer Mercox

  • Stefanov, Miroslav;Kim, Jungdae
    • Journal of Pharmacopuncture
    • /
    • v.18 no.3
    • /
    • pp.75-79
    • /
    • 2015
  • Objectives: As the peripheral part of the primo vascular system (PVS) is difficult to visualize, we used a vascular casting material Mercox injected directly into the skin to take advantage of a simple procedure to visualize PVS structures as primo vessels (PVs) and primo nodes (PNs) in the skin. Methods: Two colors of the polymer Mercox were injected into mouse skin. After a partial maceration of the whole body with potassium hydroperoxide solution, we anatomized it under a stereomicroscope to trace the Mercox that had been injected into the PVS. Results: Injection of Mercox directly into the skin allowed the PVs and the PNs to be visualized. This approach can fill the PVS when the material is ejected out of the PVs or PNs. The shapes, sizes, and topographic positions of the nodes and the vessels are the hallmarks used to identify the PVS in skin when Mercox is used as a tracer. Conclusion: The direct injection of the casting material Mercox into skin, with modified partial maceration procedures, is a promising method for visualizing the PVs and the PNs in the peripheral part of the PVS in skin. The polymer Mercox can penetrate through the primo pores of the primo vascular wall and fill the PVs and the PNs. The data prove that PVs and PNs exist on the hypodermal layer of the skin.

Analysis of Pore Structure for Porous Body with Coal Fly ash and Clay (석탄회-점토계 다공체의 기공구조 분석)

  • 이기강;박천주
    • Korean Journal of Crystallography
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1998
  • Porous body was prepared from coal fly ash 70 wt%0clay 30 wt% slip using DCC(Direct Coagulated Casting) method. Effect of the specific gravity of the slip on the pore size and distribution of the sintered body was examined by the SEM observation of microstructure and mercury porosimetry measurement of the pore size distribution. Average pore size of the porous sintered body was about 2.5μm for all slips with specific gravity of 1.55, 1.60 and 1.65g/cm3, respectively. Sintered body prepared from the slip of specific gravity of 1.60g/cm3 have the narrowest pore size distribution. slip of specific gravity of 1.55g/cm3 shows broader pore size distribution due to slow gellation process. Slip of specific gravity of 1.65g/cm3 required large amount of deflocculant and showed large variation of the viscosity with addition of coagulant which resulted in very unstable slip properties.

  • PDF

Realistic and Fast Depth-of-Field Rendering in Direct Volume Rendering (직접 볼륨 렌더링에서 사실적인 고속 피사계 심도 렌더링)

  • Kang, Jiseon;Lee, Jeongjin;Shin, Yeong-Gil;Kim, Bohyoung
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.5
    • /
    • pp.75-83
    • /
    • 2019
  • Direct volume rendering is a widely used method for visualizing three-dimensional volume data such as medical images. This paper proposes a method for applying depth-of-field effects to volume ray-casting to enable more realistic depth-of-filed rendering in direct volume rendering. The proposed method exploits a camera model based on the human perceptual model and can obtain realistic images with a limited number of rays using jittered lens sampling. It also enables interactive exploration of volume data by on-the-fly calculating depth-of-field in the GPU pipeline without preprocessing. In the experiment with various data including medical images, we demonstrated that depth-of-field images with better depth perception were generated 2.6 to 4 times faster than the conventional method.

Simi-solid 재료의 직접압연 공정해석

  • 김영도;강충길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.518-523
    • /
    • 1993
  • A computer program has been developed for analyzing the two-dimensional unsteady conservation equations for transport phenomena in the ool region of direct rolling with semi-solid metal in order to describe the velocity and temperature, and the solidification process of the semi-solid metal. The energy equations of cooling roll is solved simultaneously with semi-solid metal in order consider heat transfer through the cooling roll. The FDM(finite difference method) and FEM(finite element method) are used in region of pool and roll, respsctively, to reduce computing time and to improve accuracy of calculation. In the present study, influence of solid fraction and casting speed are investigated in a point of view of strip formability with semi-solid metal.

  • PDF

Development of Enzyme Immobilization Method to Remove Interference by Physiological Chemicals for Implantable Glucose Sensors (이식형 혈당 센서의 생리활성 물질에 의한 방해 효과를 제거하기 위한 새로운 효소고정법 개발)

  • Chung, T.D.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.72-73
    • /
    • 1998
  • A new method for enzyme immobilization has been developed to remove interference by potential interferents in body fluids. Instead of using electron mediators, we chose direct hydrogen peroxide measurement route. Extremely hydrogen peroxide-selective polymer was coated as an inner membrane to exclude interferents and then glucose oxidase(GOx) was entrapped by electropolymerization of inert monomers. There was no solvent casting step throughout the whole fabrication procedure but all membranes on Pt-Ir electrode were formed by electropolymerization. Thus, membrane thickness, quantity of enzyme loaded and can be controlled by electrochemical parameters. As a result, reproducibility of biosensor characteristics becomes remarkably improved in terms of mass production.

  • PDF

Fixed prostheses fabricated by direct metal laser sintering system: case report (Direct metal laser sintering 방식을 이용하여 제작한 다양한 고정성 보철물 수복 증례)

  • Baek, Ju-Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.246-254
    • /
    • 2016
  • Nowadays, 3 dimentional (3D) printing, especially Direct Metal Laser Sintering (DMLS) system is used in dentistry. DMLS system has recently been introduced for fabrication metal framework for metal ceramic crowns to overcome the disadvantages of the casting method and computer aided design/computer aided manufacturing (CAD/CAM) milling system. DMLS system uses a high-temperature laser beam to selectively heat a substructure metal powder based on the CAD data with the framework design. A thin layer of the beamed area becomes fused, and the metal framework is completed by laminating these thin layers. Utilizing DMLS system to fabricate fixed prostheses is expected to achieve free-from shaping without mold and limitations from cutting tools, fabricate prostheses with complex geometry, prevent distortion and fabrication defects that inherent to conventional fabrication methods. The purpose of this case report is to demonstrate various fixed prostheses such as long span fixed prostheses, post to achieve satisfactory results in functional and esthetic aspects.