• Title/Summary/Keyword: Direct Measuring Method

Search Result 295, Processing Time 0.036 seconds

Application of Vision-based Measurement System for Estimation of Dynamic Characteristics on Hanger Cables (행어케이블의 동특성 추정을 위한 영상계측시스템 적용)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.1-10
    • /
    • 2012
  • Along with the development of coasts, islands and mountains, the demand of long-span bridges increases which, in turn, brings forth the construction of cable-supported bridges like suspension and cable-stayed bridges. There are various types of statically indeterminate structures widely applied that supported the main girder with stay cables, main cables, hanger cables with aesthetic structural appearance. As to the cable-supported bridges, the health monitoring of a bridge can be identified by measuring tension force on cable repeatedly. The tension force on cable is measured either by direct measurement of stress of cable using load cell or hydraulic jack, or by vibration method estimating tension force using cable shape and measured dynamic characteristics. In this study, a method to estimate dynamic characteristics of hanger cables by using a digital image processing is suggested. Digital images are acquired by a portable digital camcorder, which is the sensor to remotely measure dynamic responses considering convenient and economical aspects for use. A digital image correlation(DIC) technique is applied for digital image processing, and an image transform function(ITF) to correct the geometric distortion induced from the deformed images is used to estimate subpixel. And, the correction of motion of vision-based measurement system using a fixed object in an image without installing additional sensor can be enhanced the resolution of dynamic responses and modal frequencies of hanger cables.

Relationship of Types of Foot Shape and Favorite Shoes Shape of Female University Students (여대생의 발 유형과 선호 구두 형태와의 관계)

  • Lee, Jin-Hee;Kim, Kyung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.12 no.1
    • /
    • pp.75-84
    • /
    • 2003
  • The objective of this paper was to analyse the foot type of female university students by the direct and indirect measure of foot and the measures of foot outline. The results were as follow: 1. The length and the width of foot were small and ankle slender and the modification of the big toe slight. 2. The analysis on the 16 measure items revealed five factors; the first factor was related to the width and girth of foot, the second one to the length of foot, the third one to the transformation of the little toe, the fourth one to the height of foot, the fifth one to transformation of the big toe. 3. The grouping on the shape of foot revealed three types. The inline angle of foot was the smallest in average in the type 1, while it appeared to be middle in the other types. The wider foot shapes were grouped as type 2 because their inline and outline angles of foot were the biggest in average. In the type 3, the big toe was curved a lot, since it was the largest in average. 4. From the naked eye measuring method, classification from which toe was popped-out told that Egyptian foot was 30.9%, Greek foot 27.9%. On the other hand, the instrumental method showed that Egyptian foot was 57.3%, Squared foot 35.3% and Greek foot 7.4%. 5. The result from the analysis about the traits of foot shape by the degree of the arch formation of bottom foot, showed that 33.8% had the normal foot, 66.2% slightly flat foot or middle one. There was no one with rigid flat foot. 6. The shoes size they declared were that 240cm was 33.3%, 235cm 18.1% and 245cm 18.1%. The shape of their shoe heel were flat heel(34.8%), cuban heel(25.5%), and narrow straight heel(19.9%); and that of the shoe toe were round toe(25.4%), oval toe(20.4%) and squared toe(20.4%). 7. The discomforting parts when they wear shoes were the little toe(35.4%), the rear of foot(13.9%), and the width of foot(13.9%), which was related to their dislike of shoe with the pointed toe.

  • PDF

A Study of Actual Condition on Operation and Management of Environmental Infrastructure in the Geum River System (금강수계 내 환경기초시설 운영실태에 관한 연구)

  • Lee, Jae-Woon;Park, Dong-Gi;Kwon, Young-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The various environmental problems that we face on today are basically about environmental quality. Since early 1960s affluent material was produced because of remarkable economic growth by many cooperations. However, for the lack of environmental policy, environmental pollutions has been serious. The central government should transfer the producing and consuming structure to environmental affinity through the regulations for developing Korea as a model of environmental nation which takes an active part in global environmental programme and in which the environment and economy are well harmonized. Moreover, the central government should take the lead in prevention of environmental pollution through the direct policies such as strengthening the discharge limit or setting up environmental basic institutions by securing budget for conserving environment. This thesis emphasize on the public institution among many environmental basic institutions for environmental anti-pollution project. It will find the problems with running those institutions, and will suggest the preview of improvement. Also, it is necessary to investigate of variation trend for inflow and pollutant loading to environmental infrastructure as increased of the diffusion rate as established and maintenance of sewer system. The purpose of this study is to investigate for inflow and pollutant loading to environmental infrastructure, and also to provide the method of efficiently maintenance and management. The results obtained were summarized as follows; 1. Survey of actual condition on operation and management of environmental infrastructure was evaluated the propriety of treatment process and problem of plant management. 2. Analysis of pollutant loading contribution for river system of environmental infrastructure with data analysis of water quality measuring network. 3. To investigate on case study for efficiently maintenance and management of environmental infrastructure. The result on this study was provide the method of efficiently maintenance and management with survey for establish and repair of sewer system and survey of actual condition on operation and management of environmental infrastructure in the water area of discharge to Geum River System. Application as guideline for establish and management of environmental infrastructure, and management of Geum River System. Also, application for preliminary data for fulfill-assess of total effluent regulation of water pollution.

Neck-Collar Fitness According to the Neck Movement of Adult Males - Centered on Neck Surface Changes - (성인(成人) 남자(男子)의 경부(頸部) 동작시(動作時) 밀착형(密着形) 칼라 적합성(適合性)에 관(關)한 연구(硏究) - 경부(頸部) 체표면(體表面) 변화(變化)를 중심(中心)으로 -)

  • Shim, Boo-Ja;Lee, So-Young
    • Journal of Fashion Business
    • /
    • v.5 no.2
    • /
    • pp.49-65
    • /
    • 2001
  • This thesis aims to reveal the unsatisfactory unfitting factors in the tight collars of adult males' dress shirts for the purpose of improving neck-collar fitness. For this study, nine adult males were chosen as the subjects. When the subjects erected their necks upright, the researcher conducted an experiment, using the direct anthropometrical measuring method and the gypsum method by turns, in order to understand neck shapes by way of right-neck lateral flection, left-neck lateral flection, neck flection, neck extension, right neck rotation, and left neck rotation. And then, the propriety of allowances from body surface alteration was verified by analyses through the measurement of wearing comfortableness and clothing pressure in two sorts of ready-made dress shirts, which had different allowances. The consequences of this study are as follows: 1. In length alteration to movement, a decrease was found in the opposite (and an increase in the identical) directions of right-neck lateral flection, left-neck lateral flection, and neck flection movements. Also, when the subjects shook their heads, an increase was seen by 0.42$\sim$0.63cm in neck girth, 0.31$\sim$1.12cm in 3cm-above-the-neck base girth, and 1.16cm in neck extension of 3cm-above-the-neck base girth. 2. As a result of the drafts of surface measurement, the alteration ratios of dimensions and vertical length dropped in the identical directions of the movement, but grew in the opposite directions. A reverse change was shown in horizontal length. The rough widening gaps for making drafts were 0.7cm in front left and right, and 0.2cm in back left and right of 3cm-above-the-neck base girth. On the whole, the space was about 1.8cm, while there was no significant variation between the upright stationary test and the movement test. 3. There were important differences between the two kinds of ready-made dress shirts (Type A: 1cm allowance in neck girth; Type B: 2cm allowance) in clothing pressure and wearing comfortableness. That is, Type A had higher pressure and more uncomfortable sense of wearing. In other words, as clothing pressure and wearing comfortableness are negatively related to each other, Type A's greater clothing pressure led to worse wearing comfortableness.

  • PDF

Thermal properties of silica fume-SiO2 based porous ceramic fabricated by using foaming method (직접 발포법을 이용해 제조된 실리카 흄-SiO2계 다공성 세라믹의 열적 특성)

  • Ha, Taewan;Kang, Seunggu;Kim, Kangduk
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.4
    • /
    • pp.182-189
    • /
    • 2021
  • Porous ceramics were manufactured using the foaming method for the development of inorganic insulating materials. Silica fume and SiO2 were used as main raw materials, and bentonite was used as a rapid setting agent for uniform structure formation of porous ceramics. The porous ceramics were sintered at 1200℃, and porosity, density, compressive strength, microstructure and thermal conductivity were analyzed. As the content of silica fume to SiO2 of the porous ceramics increased 70 to 90 %, the specific gravity increased from 0.63 to 0.69, and the compressive strength increased from 9.41 Mpa to 12.86 Mpa. But, the porosity showed a tendency to decrease from 72.07 % to 70.82 %, contrary to the specific gravity. As a result of measuring the thermal conductivity, the porous ceramic with a silica fume content of 70 % showed a thermal conductivity of 0.75 to 0.72 W/m·K at 25 to 800℃, respectively, and, another that a silica fume content of 90 % showed a 0.66~0.86 W/m·K. So the lower the silica f ume content, the lower the thermal conductivity, which was conf irmed to be consistent with porosity result. As a result of microstructure analysis using SEM (Scanning Electron Microscope), pores in the range of tens to hundreds ㎛ were observed inside and outside the porous ceramic, and it was confirmed that the pore distribution was relatively uniform.

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

Psychological burden for legal responsibility of 119 emergency personnels (119구급대원의 법적책임에 대한 심리적 부담감)

  • Lim, Jae-Man;Yun, Seok-Jeong;Lim, Gwan-Su;Kang, Shin-Kap;Choi, Eun-Sook;Seo, Kyung-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.1
    • /
    • pp.87-96
    • /
    • 2009
  • Purpose : To grasp the mental burden for legal responsibility that rescue members have in the performance of job. Method : Questionnaire was presented to rescue members serving in 2 direct control safety centers of fire station located in Seoul, Daejon, Incheon, Kwangju, Busan, Daegu and Ulsan. Results : 1. Questioned whether they have mental burden for legal responsibility while performing job on the site, the rescue members responded : very burdensome in 38.0%, burdensome in 56.0%, moderate in 4.5%, not burdensome in 1.0%, no burden at all in 0.5%. 2. Questioned on the first aid treat for which they have the most mental burden, the rescue members responded : intubation into trachea laryngeal mask airway(LMA) in 40.4%, automatic external defibrillator in 16.3%, securing vein providing sap(medicine) in 10.8%, basic cardiopulmonary resuscitation in 7.2%, eliminating foreign matters inserted into body in 5.4%, stanching external bleeding and treating injury in 5.4%, fixing extremities and spine by using splint in 1.8%, measuring the symptom of vitality in 1.2%, providing oxygen in 0.0%. 3. Questioned whether experiencing legal problem or firm petition(complaint) raised by patient while serving as rescue members, they responded : experiencing a complaint in 41.6%, experiencing no complaint in 58.4%. Asked to indicate the stress level in the scale of which they suffered when lawsuit or firm petition was raised, 0(weak)-10(strong), they answered 8.8 in average. 4. Questioned whether 119 rescue members put the legal responsibility in case that they cause damage to patients intentionally in performing, they responded to the inquiry 3.66 in average(of 5.00). It represented meaningful differences (F=2.874, p=.024) whether they had license or not. 5. In future, legal action will raise against the rescue member by 99% because of people's rights improvement(63.1%), high expectations for the rescue system(29.5%), non-licensed rescue members(5.1%). Conclusion : It was found that the rescue members had severe mental burden for advanced life support which was investigated to have low enforcement rate in the preceding research, for instance, intubation into trachea securing vein management by using automatic external defibrillator. To improve the qualitative level of rescue service in the fire fighting, it may be required to construct the environment that eliminates the mental burden of rescue members for legal responsibility.

  • PDF

Workload Measurement of Home Health Care Nurses상 Services using Relative Value Units (가정간호행위 업무량의 상대적 가치 측정에 관한 연구)

  • 이태화;박정숙;김인숙
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.6
    • /
    • pp.1543-1555
    • /
    • 2000
  • Home health care is moving into a set of new realities. An era of competition and cost containment has arrived. Before nurses are able to contain costs or describe the relationship between nursing activities, cost must be accurately measured based on the nurse's workload. Nurses in home health care usually desire to measure expenses for one of three reasons : reimbursement, management, or research. The purpose of the study was to investigate the work input by Registered Nurse in each of the home health care activities by relative value units and identify the factors affecting the nurses' total work input in health care services. To measure the work input by nurses, work was defined by four dimensions: time, physical effort, mental effort, and stress. This study used a descriptive-correlational design. Data collection consisted of two phases. In phase I, data on home health activities performed by nurses were collected. In phase II, data on nurses' time, physical effort, mental effort, and stress in each of home health care activities discovered phase I were collected. In this method, the respondent was asked to rate a service in relation to a reference service using a ratio scale. The sample included 39 home health care nurses. The results of the study indicated that home health care activities performed by the nurses were in 10 categories and 69 items. Measuring the relative work inputs in each of home health care activities, and foley catheterization was selected as the reference to service. In terms of time and physical effort dimensions, full bath service was rated as the most strenuous among 69 activities by the respondents, and intramuscular injection was rated as least. It was found that emergency treatment required the highest mental effort and the highest stress, while blood sugar tests required the lowest mental effort. Approximately 91.3% of the variance in total work input was accounted for by the linear combination of time, physical effort, mental effort judgement, and stress. Examining the regression coefficients of those variables, physical effort, time, and stress were found as the predictors which were significantly associated with the total work of nurses in home health care. Professional nursing's next step in the conundrum of economic volatility is to develop a tool to reflect the interaction of functional deficiency and direct professional nursing care. And this will be a more accurate predictor of nursing resource use and ultimately a great forcaeter cost.

  • PDF

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

A Study on the Contact Resistance according to the Tightening and Overlapping area of Bus Bar (부스 바의 체결 및 중첩 구간에 따른 접촉 저항에 관한 연구)

  • Kim, Hyun-Woo;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.56-62
    • /
    • 2018
  • The bus bar is an electrical connection widely used for the power supply of skyscrapers and power distribution and industrial equipment electrical panels in industrial plants. There are various materials to be considered in the design of the bus bar, such as material based on the use environment, the sectional area according to the power capacity, the length of the surface circumference, and the tightening method. Even with a bus bar manufactured to a size of sufficient power capacity in the design, if the actual tightening is incorrect, it may lead to fire due to deterioration. For these reasons, a variety of research on the temperature rise of the electrical contact point has continued. However, the temperature rise of the contacts is a consequence of the result, not a direct cause. In this paper, the influence of contact resistance on the fastening force and the overlapping section of the bus bar are investigated by measuring the change in resistance from building the specimen. A total of eight bus bar specimens were manufactured and measured. Resistance was measured by varying the clamping force and the interval between overlapping sections when the specimens were crossed. We propose a safe power connection model by analyzing the contribution of these factors to the actual contact resistance change.