• Title/Summary/Keyword: Direct Measuring Method

Search Result 295, Processing Time 0.022 seconds

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

An External Surfaces Modeling of Inlay/onlay Using Geometric Techniques (기하학 기술을 이용한 인레이/온레이의 외면 모델링)

  • Yoo kwal-Hee;Ha Jong-Sung
    • The KIPS Transactions:PartA
    • /
    • v.12A no.6 s.96
    • /
    • pp.515-522
    • /
    • 2005
  • This paper presents a method for effectively modeling inlay/onlay prostheses restoring a tooth that are partially destroyed. An inlay/onlay is composed of internal surface adhering to an abutment, and external surface revealed to the outside sight. Internal surfaces are modeled using Minkowski sum expanding the grinded surface parts of abutments so that the internal surfaces can adhere to the abutments with closer contact. In modeling external surfaces, we exploit 3D mesh deformation techniques: DMFFD(direct manipulation free-form deformation)[19] and MWD(multiple wires deformation)[17] with three kinds of informations: standard teeth models, mesh data obtained by scanning a plaster cast of a patient's tooth, FGP(functionally guided plane) measuring the occlusion of the patients's teeth. The standard teeth models are used for building up the basic shapes of external surfaces, while the plaster fast and FGP data are used for reflecting the unique properties of adjacent md occlusal surfaces of the patients's teeth, which are slightly different to each other but very important for correct functioning. With these informations as input data, the adjacent and occlusal surfaces are automatically generated as mesh data using the techniques of DMFFD and m, respectively. Our method was implemented so that inlay/onlay prostheses fan be designed more accurately by visualizing the generated mesh models with requirements by dentists.

Evaluation of Amino Acid and Energy Utilization in Feedstuff for Swine and Poultry Diets

  • Kong, C.;Adeola, O.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.7
    • /
    • pp.917-925
    • /
    • 2014
  • An accurate feed formulation is essential for optimizing feed efficiency and minimizing feed cost for swine and poultry production. Because energy and amino acid (AA) account for the major cost of swine and poultry diets, a precise determination of the availability of energy and AA in feedstuffs is essential for accurate diet formulations. Therefore, the methodology for determining the availability of energy and AA should be carefully selected. The total collection and index methods are 2 major procedures for estimating the availability of energy and AA in feedstuffs for swine and poultry diets. The total collection method is based on the laborious production of quantitative records of feed intake and output, whereas the index method can avoid the laborious work, but greatly relies on accurate chemical analysis of index compound. The direct method, in which the test feedstuff in a diet is the sole source of the component of interest, is widely used to determine the digestibility of nutritional components in feedstuffs. In some cases, however, it may be necessary to formulate a basal diet and a test diet in which a portion of the basal diet is replaced by the feed ingredient to be tested because of poor palatability and low level of the interested component in the test ingredients. For the digestibility of AA, due to the confounding effect on AA composition of protein in feces by microorganisms in the hind gut, ileal digestibility rather than fecal digestibility has been preferred as the reliable method for estimating AA digestibility. Depending on the contribution of ileal endogenous AA losses in the ileal digestibility calculation, ileal digestibility estimates can be expressed as apparent, standardized, and true ileal digestibility, and are usually determined using the ileal cannulation method for pigs and the slaughter method for poultry. Among these digestibility estimates, the standardized ileal AA digestibility that corrects apparent ileal digestibility for basal endogenous AA losses, provides appropriate information for the formulation of swine and poultry diets. The total quantity of energy in feedstuffs can be partitioned into different components including gross energy (GE), digestible energy (DE), metabolizable energy (ME), and net energy based on the consideration of sequential energy losses during digestion and metabolism from GE in feeds. For swine, the total collection method is suggested for determining DE and ME in feedstuffs whereas for poultry the classical ME assay and the precision-fed method are applicable. Further investigation for the utilization of ME may be conducted by measuring either heat production or energy retention using indirect calorimetry or comparative slaughter method, respectively. This review provides information on the methodology used to determine accurate estimates of AA and energy availability for formulating swine and poultry diets.

A study on the evaluation of lower heating value using heat balance method in industrial waste incineration facilities (열정산방법을 이용한 사업장폐기물 소각시설의 저위발열량 분석·평가 연구)

  • Ko, Youngjae;Kang, Jun-Gu;Kwon, Young-Hyun;Yoo, Ha-Nyoung;Kwon, Jun-Hwa;Jang, Mi-Jeong;Jeon, Tae-Wan;Shin, Sun-Kyoung
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.31-38
    • /
    • 2018
  • The energy recovery rate estimation method proposed through the Waste Control Act does not take into account the energy used in practice. In addition, the method for measuring a lower heating value, which is the main factor of the energy recovery rate, was carried out through a small sampling amount, and thus the representative value of the waste was not reflected. With the revised estimation method (Notification No. 2015-215 of the Ministry of Environment), the energy recovery rate should be estimated based on the actual amount of energy used, and a heat balance method was proposed as a way to estimate the lower heating value. In this study, the lower heating value was estimated for seven industrial waste incineration facilities according to the revised estimation method. All data used in the estimations were achieved from measurement instruments applied to each of the incinerators and through direct measurements taken by the operators for the purposes of calculation. As a result, the lower heating value was estimated to be about 3,404.7 kcal/kg for the seven industrial waste incineration facilities.

Measurement of Leaf Area of Soybeans (대두엽면적의 간이측정법)

  • Kwon-Yawl Chang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.4 no.1
    • /
    • pp.93-95
    • /
    • 1968
  • The importance of leaf area as related to transpiration and photosynthesis is generally recognized. In general, a compound leaf of soybean consist of one main leaflet and two side leaflets from each node of the stem. Takahashi and Fukuyama (1919) classified soybeans into three types, namely the long leaf type, round leaf type, and intermediate type, in which the last one had round leaves at the base and long leaves in the upper part of the stem. Nagai (1925) and Takahashi (1935). dealt with the genetics of the leaf form and association with other characters. The closely relationships, the correlation coefficients from 0.64 to 0.73, were shown between the leaf area and the soybean yield in the experiments by Nagai (1942). Nagata (1950) also tested the varietal differences of the variation of leaf length and its ratio to the leaf width on the nodes of stem, and finally divided varieties into five types. Three methods of measuring area of strawberry leaves were used by Darrow (1932). The first involved determining a factor to be used with length or length ${\times}$width measurements. The second method involved placing leaves on pieces of cardboard of known area cut to the shape of the leaves. Direct use of the planimeter on intact leaves was Darrow's third method. Miller (1938) enumerated several methods to determine the leaf surface area in plants, some of which were extremely laborious and required removing leaves from plants. They included tracing outlines of leaves on paper and measuring the enclosed area with a planimeter or cutting out the traced areas and comparing the weights obtained with the weight of a known paper. Another method involved placing the form of the leaf on sensitized paper with the area being determined by measuring or weighing as above. Miller further stated that the photoelectric cell can also be utilized to estitmate leaf area. Working with field beans, Davis (1940) found that 0.004517 (length ${\times}$ width) of the center leaflet was the most nearly accurate of four methods attempted. A simple procedure to measure leaf area in corn was devised 1 y Montgomery (1911) and used by Kiesselbach (1950). The formula was length ${\times}$ width ${\times}$ 0.75. Stickler et al. (1961) have successfully used length times width ${\times}$ 0.747 to estimate area of grain sorghum leaves. Bhan and Pande(1966) has also used length ${\times}$ width ${\times}$ 0.802 to determine leaf area of rice varieties. The main objectives of the present investigation were to develop an accurate, rapid method to determine leaf area in soybean varieties and to examine certain data associated with leaf area determinations.

  • PDF

A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image (노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법)

  • Kim, Kuk-Won;Kim, Min-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.909-916
    • /
    • 2009
  • This paper presents the automatic vision algorithm to generate and calibrate reference phase plane to improve the accuracy of 3D measuring machine of using phase shifting projection moire method, which is not traditional N-bucket method, but is based on direct image processing method to the pattern projection image. Generally, to acquire accurate reference phase plane, the calibration specimen with well treated surface is needed, and detailed calibration method should be performed. For the cost reduction of specimen manufacturing and the calibration time reduction, on the specimen, not specially designed, with general accuracy level, an efficient calibration procedure for the reference phase generation is proposed. The proposed vision algorithm is developed to extract the line center points of the projected line pattern from acquired images, derive the line feature information consisting of its slope and intercept by using sampled feature points, and finally generate the related reference phase between line pairs. Experimental results show that the proposed method make reference phase plane with a good accuracy under noisy environment and the proposed algorithm can reduce the total cost to make high accurate calibration specimen, also increase the accuracy of reference phase plane, and reduce the complex calibration procedure to move grid via N-bucket algorithm precisely.

Screening of Inhibitors of Platelet Aggregation from Edible Plants (산채류로부터 혈소판응집 억제물질의 검색)

  • Yoon, Min-Ho;Lim, Chi-Hwan;Oh, Jin-Hwan;Lee, Jong-Chul;Choi, Woo-Young
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.267-274
    • /
    • 1997
  • To select potential inhibitors of platelet aggregation from large numbers of crude plant extracts, the modified thin smear method for the anti-platelet aggregating activity using platelet rich plasma was further modified by direct observation under a light microscope without staining the smear. The activities determined by the method were coincided with those by the electrical impedence method using whole blood, when ADP or collagen was employed as the aggregating agent. Among 130 varieties of edible and herbal plants which collected from markets or experimental farms of agricultural research institutes, those showed the anti-platelet aggregating activities were selected by testing the crude methanol extracts: Aster scaber, Aster tataricus, Ligularia stenocephala, Platycodon glaucum Allium victorialis, Allium oderum, Moros bombycis, Portulaco oleracea, Aamthopanax sessiliflorus and Rosa davurica. However, some of them activated the platelet aggregation under the same assay conditions: Pimpinella brachycarpa, Hosta plantaginea, Capsella bursapastoris, Fagopyrm esculentum, Prunus mume, Rubus coreanus and Limaria japonica. In addition, those revealed the antioxidant activities were selected by measuring the abilities to scavenge superoxide anion radicals: Pteridium aquilinum, Aster scaber, Ligularia fischeri, Chrysanthemum zawadskii, Artemisia capipparis, Cirsium setidens, Commelina communis and Capsella bursapastoris among edible plants.

  • PDF

A Study of Clinical Usefulness of Carbohydrate Deficient Transferrin in Patients with Alcoholic Liver Disease (알코올성 간 질환 환자의 Carbohydrate Deficient Transferrin의 임상적 유용성 연구)

  • Son, Gye-Sung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.8-15
    • /
    • 2005
  • It is well known that intaking alcohol chronically and heavily causes many formsof physical systemic distress including serious chronic alcoholic liver disease such as alcoholic hepatitis, fatty liver, liver cirrhosis and hepatoma. Carbohydrate-deficient transferrin (CDT) is known as a specific marker in detecting and monitoring alcohol associated disease. Weanalyzed various alcohol-associated parameters to evaluate the clinical usefulness of CDT. The first patient group consisted of fifty patients, who had been diagnosed with alcoholic liver disease from January 2003 to June 2004 at Chungnam National University Hospital. The second group consisted of 12 patients with non-alcoholic liver disease. The third group consisted of 19 teetotalerswho had visited the hospital for the purpose of routine healthcare checks. Various hepatic parameters such as CDT, $\small{\Gamma}$-GT (gamma-glutamyl transferase), AST (aspartate aminotransferase) and ALT (alanine aminotransferase) were compared in the three groups. CDT and AST increased in direct proportion to the amount and duration of alcohol consumption with high significance, but $\small{\Gamma}$-GT and ALT showed arbitrary patterns with no statistical significance. The sensitivities of CDT, $\small{\Gamma}$-GT, AST and ALT were 74 %, 96 %, 68 % and 58 %, respectively and the specificities were 95 %, 74 %, 68 % and 79 % in order respectively. The correlation study of CDT with $\small{\Gamma}$-GT, AST and ALT showed a very low value of correlation coefficients, implying that CDT could be taken as an independent parameter in evaluating alcohol liver disease compared to $\small{\Gamma}$-GT, AST and ALT. This present study suggested that CDT coud be one of the most useful parameters in reflecting the amount and duration of alcohol consumption as well as being another independent parameter in assessing and following up patients with alcoholic liver disease. Moreover we recommend it is the best method of measuring both CDT and $\small{\Gamma}$-GT in patients with alcoholic liver disease.

  • PDF

Study on Radiation dose in according to Magnification's rate in fluoroscopy (투시 조영 검사 시 확대율에 따른 피폭선량에 관한 고찰)

  • Kang, Kyeong-Mi;Hong, Seon-Sook;Seong, Min-Sook;Song, Woon Heung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.39-44
    • /
    • 2013
  • Purpose : The purpose of this study is the magnification rates depending on the area of patient dose (DAP) and glass dosimeter see the change of the dose according to the dose characteristics of low-magnification aims to raise standards. Materials and Method : Direct DR equipment Sonialvision DAR-8000f, Shimadzu was used, the patient entrance dose measurements to the surface of the Rando Phantom of the neck and the abdomen was placed on the Xi unfors. glass dosimeter for measuring organ doses at the same time the Rando Phantom of the major organs in place by inserting a 9 ", 12", 15 ", 17" and 30 seconds for each magnification were measured according in fluoroscopy. DAP meter area of the patient dose was measured. Result : Esophagography at 17" 143% than 9"magnification the average area dose was increased. Organ dose of Esophagography at 17" was decreased 25.32% than 9" magnification. UGI at 17" was increased 129.73% DAP than 9" magnification. Organ dose of UGI at 17" was decreased 23.32% than 9" magnification. Where the major organs of magnification at 17" were decreased(lung -25.96%, stomach -33.09%, spleen -27.81%, liver -4.92%) than 9" magnification. Conclusion : Expected to get better quality image While using the proper magnification, and have recognition that difference Organ doses and DAP meter in fluoroscopy.

  • PDF

A Comparative Evaluation of Urban Quality of Life Using AHP (AHP를 이용한 도시의 삶의 질 비교)

  • Kim, Dong-Yoon
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.1
    • /
    • pp.33-41
    • /
    • 2013
  • Considering the fact that quality of life(QOL) conceptually has objective and subjective attributes but difficulties in measuring the subjective aspect cause a number of studies not to be balanced, this study exploits AHP(Analytical Hierarchy Process) which has been used for systematic decision making to include the other aspect. As the first step of the process decision making hierarchy model is set by content analysis of the UNDP QOL index and additional review of previous studies. 'Improving urban QOL' is a goal on top, 'Economical QOL', 'Environmental QOL', 'Social QOL' and 'Physical QOL' are dimensions of sub-goal(means objectives), and further decomposition follows. AHP shows that the dimensions of economical, physical, environmental and social QOL scored higher respectively. The aim of the model is to measure and prioritize the urban QOL in the two case study cities. The final score of the each city could be computed by integration of relative weights of dimensions for urban QOL. The final score of QOL for city A was 0.6642 and for city B the figure decreased to 0.3358. The method of this study could be used in stages of the process of urban planning. First stage is when planners try to have a correct and reliable perspective from the existed conditions of the city. Second stage is when the projects should be investigated to be confirmed for their efficiency. In other words planners can direct the scarce resources towards the aspects of QOL which are more important. And the results revealed that using AHP creates opportunity to involving the different groups in the stage of criteria weighting so that the attitudes of local community could be integrated well to the decision making to be suitable for a new paradigm of participatory and communicative planning.