• Title/Summary/Keyword: Direct Measuring Method

Search Result 292, Processing Time 0.026 seconds

A Study on Comparing the CO2 Emission Estimating Result for Construction Equipment (건설장비 CO2배출량산출결과 비교연구)

  • Kim, Byung-Soo;Jang, Won-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1675-1682
    • /
    • 2013
  • To resolve the Global Warming problem, it have to reduce $CO_2$ emission. Korea need to do actively more the effort to reduce the emission because $CO_2$ emission per person is top level in the world. It is performing variously. However, we should recognize the $CO_2$ emission attribute to decrease $CO_2$. Analyzing $CO_2$ emission of the construction equipment is important in this aspect. Present, the most popular $CO_2$ emission measuring method is the way using fuel consumption and emission factor. But this method have the problem of reliability because can't reflect the factor being out of proportion at fuel consumption. This study analyzed the reason of difference and compared to the emission factor method after calculate $CO_2$ emission in direct measurement method.

Alterations in Left ventricular End-systolic Wall Stress During Short-term Follow-up After Correction of Isolated Congenital Aortic Stenosis (선천성 대동맥 협착증의 술전 및 술후 단기간의 수축말기 좌심실 내벽 스트레스의 변화)

  • 김시호
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.777-784
    • /
    • 2000
  • Congenital aortic stenosis in children is characterized by "excessive" left ventricular hypertrophy with reduced left ventricular systolic wall stress that allows for supernormal ejection performance. We hypothesized that left ventricular wall stress was decreased immediately after surgical correction of pure congenital aortic stenosis. Also measuring postoperative left ventricular wall stress was a useful noninvasive measurement that allowed direct assessment for oxygen consumption of myocardium than measuring the peak systolic pressure gradient between ascending aorta and left ventricle for the assessment of surgical results. Material and Method: Between September 1993 and August 1999, 8 patients with isolated congenital aortic stenosis who underwent surgical correction at Yonsei cardiovascular center were evaluated. There were 6 male and 2 female patients ranging in age from 2 to 11 years(mean age, 10 years). Combined Hemodynamic-Ultrasonic method was used for studying left ventricular wall stress. We compared the wall stress peak systolic pressure gradient and ejection fraction preoperatively and postoperatively. Result: After surgical correction peak aortic gradient fell from 58.4${\pm}$17.6, to 23.7${\pm}$17.7 mmHg(p=0.018) and left ventricular ejection fraction decreased but it is not statistically significant. In the consideration of some factors that influence left ventricular end-systolic wall stress excluding one patient who underwent reoperation for restenosis of left ventricular outflow tract left ventricular end-systolic pressure and left ventricular end-systolic dimension were fell from 170.6${\pm}$24.3 to 143.7${\pm}$27.1 mmHg and from 1.78${\pm}$0.4 to 1.76${\pm}$0.4 cm respectively and left ventricular posterior wall thickness was increased from 1.10${\pm}$0.2, to 1.27${\pm}$0.3cm but it was not statistically singificant whereas left ventricular end-systolic wall stress fell from 79.2${\pm}$24.9 to 57.1${\pm}$27.6 kdynes/cm2(p=0.018) in 7 patients. For one patient who underwent reoperation peak aortic gradient fell from 83.0 to 59.7 mmHg whereas left ventricular end-systolic wall stress increased from 67.2 to 97.0 kdynes/cm2 The intervals did not change significnatly. Conclusion ; We believe that probably some factors that are related to left ventricular geometry influenced the decreased left ventricular wall stress immediately after surgical correction of isolated congenital aortic stenosis. Left ventricular wall stress is a noninvasive measurement and can allow for more direct assesment than measuring peak aortic gradient particularly in consideration of the stress and oxygen consumption of the myocardium therefore we can conclude it is a useful measurement for postoperative assessment of congenital aortic stenosis.

  • PDF

Application of Nonlinear Ultrasonic Method for Monitoring of Stress State in Concrete

  • Kim, Gyu Jin;Park, Sun Jong;Kwak, Hyo Gyoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.2
    • /
    • pp.121-129
    • /
    • 2016
  • As the lifespan of concrete structures increases, their load carrying capacity decreases owing to cyclic loads and long-term effects such as creep and shrinkage. For these reasons, there is a necessity for stress state monitoring of concrete members. Particularly, it is necessary to evaluate the concrete structures for behavioral changes by using a technique that can overcome the measuring limitations of usual ultrasonic nondestructive evaluation methods. This paper proposes the use of a nonlinear ultrasonic method, namely, nonlinear resonant ultrasonic spectroscopy (NRUS) for the measurement of nonlinearity parameters for stress monitoring. An experiment compared the use of NRUS method and a linear ultrasonic method, namely, ultrasonic pulse velocity (UPV) to study the effects of continuously increasing loads and cyclic loads on the nonlinearity parameter. Both NRUS and UPV methods found a similar direct relationship between load level and that parameter. The NRUS method showed a higher sensitivity to micro-structural changes of concrete than UPV method. Thus, the experiment confirms the possibility of using the nonlinear ultrasonic method for stress state monitoring of concrete members.

A Study on the Measurement of the Crack Length Using the DCPD Method for the Fracture Test of the Pipe Specimen (직류전위차법을 이용한 배관 균열 길이 측정에 관한 연구)

  • Park, Jae-Sil;Seok, Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.640-647
    • /
    • 2004
  • In order to perform elastic-plastic fracture mechanical analyses, fracture resistance curves for concerned materials are required. The unloading compliance method and the DCPD(Direct Current Potential Drop) method have been widely used for measuring the crack length and the extension for a standard specimen fracture resistance curve test. However it is difficult to apply the unloading compliance method to a real pipe fracture resistance curve test. The objective of this paper is to propose the calibration equation between the normalized crack length and the normalized electric potential, and to apply to pipe fracture experiments. For these, finite element analyses were performed with various current input locations and crack front configurations. Also the 4-point bending jig was manufactured for a pipe test and the DCPD method was used to measure crack extensions and crack lengths for a pipe test. The calculated crack length by the DCPD method agreed with the measured crack length within 5% error.

The Toxicity Test of Water Flea by Heartbeat Measurement (물벼룩의 심장박동을 이용한 독성실험)

  • Lee, Chan-Won;Kim, In-Kyung;Jeon, Hong-Pyo
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.425-432
    • /
    • 2007
  • The water flea has been used as a test organism of toxicity test for surface water. Toxicity test with water flea is categorized into two parts. One is acute toxicity test with observing immobility and mortality and the other is chronic toxicity test determined by survival and reproduction of water flea. Heartbeat measurement of water flea was designed as a short-term toxicity test in this study. Direct measurement of heartbeat under microscope by aid of video camera gives and early diagnosis of mortality in short time. Therefore, the effects of measuring illumination, measuring time, and non-feeding during the test on heartbeat of water flea was evaluated to establish a new test approach. Test organisms used in this study are Daphnia magna, a well standardizes toxicity test organism, and Simocephalus mixtus, a newly refined organism $IC_{50}$ values of these test organism by heartbeat measurement were compared and discussed. It was found that toxicity test by heartbeat measurement was a reproducible, easy and simple method accomplished in a few hours.

A comparative study on validity of AHP and conjoint analysis: a case of cosmetics preference (계층적 의사결정과 컨조인트 분석의 타당성 비교: 화장품 선호 사례 조사)

  • Lee, Ji Hye;Jeong, Hyeong Chul
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.5
    • /
    • pp.921-933
    • /
    • 2016
  • In this paper, we consider the comparisons of the personal preferences of analytic hierarchy process (AHP) and conjoint analysis (CA) which contain very relatively small number of alternatives. However, a direct performance comparison is not easy because these two methods have a much different process to achieve the final decision. Therefore, we adopt a validity and reference method with empirical case study for cosmetics preference of female college students. In case study, conjoint analysis has the merit of measuring internal validity; however, AHP has the merit of measuring predictive validity.

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

NEW ASPECTS OF MEASURING NOISE AND VIBRATION

  • Genuit, K.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.796-801
    • /
    • 1994
  • Measuring noise, sound quality or acoustical comfort presents a difficult task for the acoustic engineer. Sound and noise are ultimately jugded by human beings acting as analysers. Regulations for determining noise levels are based on A-weighted SPL measurement performed with only one microphone. This method of measurement is usually specified when determining whether the ear can be physically damaged. Such a simple measurement procedure is not able to determine annoyance of sound events or sound quality in general. For some years investigations with binaural measurement analysis technique have shown new possibilities for the objective determination of sound quality. By using Artificial Head technology /1/, /2/ in conjunction with psychoacoustic evaluation algorithms - and taking into account binaural signal processing of human hearing, considerable progress regarding the analysis of sounds has been made. Because sound events often arise in a complex way, direct conclusions about components subjectively judged to be annoying with regard to their causes and transmission paths, can be drawn in a limited way only. A new procedure, complementing binaural measurement technology combined with mulit-channel measuements of acceleration sensor signals has been developed. This involves correlating signals influencing sound quality, analyzed by means of human hearing, with signals form different acceleration sensors fixed at different positions of the sound source. Now it is possible to recognize the source and the transmission way of those signals which have an influence on the annoyance of sound.

  • PDF

Development of a Convective Sequential Production System for Aspheric Lens (전도방식 순차제조 비구면 렌즈 제조시스템 개발)

  • Kuk, Kum-Hoan;Kim, Gab-Soon;Jung, Dong-Yean
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.202-210
    • /
    • 2011
  • The fabrication method of aspheric lens is changed from machining to press molding so as to improve the productivity. In the case of the press molding method, the temperature control of the molding die is most important, because the temperature of each molding die determines the quality of lens. But any practical method for direct measuring of the lens temperature and the die internal temperature is yet unknown. Besides, in the case of the press molding system in which the heating and pressing and cooing of a die is done at separate work stations, the lens productivity of the system for small lens is yet too low. The paper shows an improved structure of convective sequential system, the lens productivity of which is three times as many as the conventional convective system. To know the die internal temperature, numerical results are given using ANSYS. A new convective sequential system is developed and tested. Finally, the Taguchi method is applied in order to optimize the setting conditions of individual work station of the system.

Development of a Small Radiant Sequential Production System for Aspheric Lens (소형 복사방식 순차제조 비구면 렌즈 제조시스템 개발)

  • Kuk, Kum-Hoan;Jeong, Jun-Hyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.67-74
    • /
    • 2010
  • The fabrication method of aspheric lens is changed from machining to press molding so as to improve the productivity. In the case of the press molding method, the temperature control of the molding die is most impotent, because the temperature of each molding die determines the quality of lens. But any practical method for direct measuring of the lens temperature and the die internal temperature is yet unknown. Besides, in the case of the press molding system in which the heating and pressing and cooing of a die is done at one work station, the cycle time for the system is yet too long. The paper shows an improved structure of radiant sequential system in which the heating and pressing and cooing of dies is done at individual work station so as to cut down the cycle time. To know the die internal temperature, numerical results are given using ANSYS. An experimental radiant sequential system is developed and tested. Finally, the Taguchi method is applied in order to optimize the setting conditions of individual work station.