• Title/Summary/Keyword: Direct Loss

Search Result 907, Processing Time 0.041 seconds

A 1.485 Gbps Wireless Video Signal Transmission System at 240 GHz (240 GHz, 1.485 Gbps 비디오신호 무선 전송 시스템)

  • Lee, Won-Hui;Chung, Tae-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.105-113
    • /
    • 2010
  • In this paper, a 1.485 Gbps video signal transmission system using the carrier frequency of 240 GHz band was designed and simulated. The sub-harmonic mixer based on Schottky barrier diode was simulated in the transmitter and receiver. Both of heterodyne and direct detection receivers were simulated for each performance analysis. The ASK modulation was used in the transmitter and the envelop detection method was used in the receiver. The transmitter simulation results showed that the RF output power was -11.4 dBm($73{\mu}W$), when the IF input power was -3 dBm(0.5 mW) at the LO power of 7 dBm(5 mW) in sub-harmonic mixer, which corresponds to SSB(Single Side Band) conversion loss of 8.4 dB. This value is similar to the conversion loss of 8.0 dB(SSB) of VDI's commercial model WR3.4SHM(220~325 GHz) at 240 GHz. The combined transmitter and receiver simulation results showed that the recovered signal waveforms were in good agreement to the transmitted 1.485 Gbps NRZ signal.

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

The Socioeconomic Cost of Injuries in South Korea (우리나라 손상의 사회경제적 비용)

  • Park, Kun-Hee;Lee, Jin-Seok;Kim, Yoon;Kim, Yong-Ik;Kim, Jai-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.1
    • /
    • pp.5-11
    • /
    • 2009
  • Objectives : This study was conducted to estimate the socioeconomic cost of injuries in South Korea. Methods : We matched claims data from national health insurance, automobile insurance and industrial accident compensation insurance(IACI), and mortality data obtained from the national statistical office from 2001 to 2003 by patients unique identifier. Socioeconomic cost included both direct cost and indirect cost: the direct cost was injury-related medical expenditure and the indirect cost included loss of productivity due to healthcare utilization and premature death. Results : The socioeconomic cost of injuries in Korea was approximately 1.9% of the GDP from 2001 to 2003. That is, 12.1 trillion KRW(Korean Won) in 2001, 12.3 trillion KRW in 2002, and 13.7 trillion KRW in 2003. In 2003, direct medical costs were 24.6%(3.4 trillion KRW), the costs for loss of productivity by healthcare utilization were 13.0%(1.8 trillion KRW), and the costs for loss of productivity by premature death were 62.4%(8.6 trillion KRW). Conclusions : In this study, the socioeconomic cost of injuries in Korea between 2001 and 2003 was estimated by using not only health insurance claims data, but also automobile insurance, IACI claims and mortality data. We conclude that social efforts are required to reduce the socioeconomic cost of injuries in Korea, which represented approximately 1.9% of the GDP for the time period specified.

Solvent-free Synthesis of Propargylic Alcohols using ZnO as a New and Reusable Catalyst by Direct Addition of Alkynes to Aldehydes

  • Hosseini-Sarvari, Mona;Mardaneh, Zahra
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4297-4303
    • /
    • 2011
  • Under solvent-free conditions, the synthesis of propargylic alcohols by direct addition of terminal alkynes to aldehydes promoted by ZnO as a novel, commercially, and cheap catalyst is described. Furthermore, the catalyst can be reused for several times without any significant loss of its catalytic activity.

Loss characteristic analysis of propulsion motor applied for high speed train (차세대 고속철도용 견인전동기 손실특성 해석)

  • Lee, Dong-Su;Kim, Shang-Hoon;Lee, Sang-Gon;Jung, Sang-Yong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1376-1382
    • /
    • 2010
  • The propulsion Motor system has changed from the DC motor system to the induction motor system. Although the induction motor system has almost reached the stage of maturity, this system also need changed to the IPMSM system for direct drive without reduction gear. Thus, the IPMSM(Interior buried Permanent magnet synchronous Motor) has been adopted to meet the driving specification. In this paper, loss characteristic analysis of IPMSM has been performed using adopted F.E.M.

  • PDF

Power Factor Correction of the Single Stage AC/DC Converter with Low Conduction Loss and High Efficiency (고효율, 저손실을 갖는 1단 교류/직류 변환기의 역률제어)

  • 류명효;차영길;최병조;김흥근
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.418-422
    • /
    • 1998
  • A new single stage AC/DC converter based on the forward converter is proposed. The proposed converter offers both the high power factor and the direct conversion from ac line to dc output voltage. Also, the proposed converter reduces the diode conduction loss, so improves the overall efficiency of the converter, compared with other alternatives. The principles of operation and the simulation results of the proposed converter are presented. A 100 W prototype was built and tested to show the potential of applications of the proposed converter.

  • PDF

Fabrication of waveguide using UV Ar-ion laser direct writing (Laser Direct Writing 방법을 이용한 광도파로 제작)

  • Kang H. S.;Suh J.;Lee J. H.;Kim J. O.
    • Laser Solutions
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 2005
  • The laser direct writing method using a UV Argon-ion laser is studied for fabrication of waveguide. The laser direct writing system is constructed with a vision camera, a xy-stage, a motion controller and the delivery components of a laser beam. The UV Argon-ion laser has wavelength range of $333.6\~363.8$ nm. A photo-active UV curable polymer for a planar light-wave circuit(PLC) of single mode is used. This polymer is irradiated by Argon-ion laser and developed by a solvent after a post-baking. The optimum laser direct writing condition is obtained experimentally by changing various process parameters such as laser power, writing speed and focal length. The propagation and coupling loss of a optical waveguide was measured as 1dB/cm and 0.6dB/cm, respectively. Also, the minimum width of waveguide of $100{\mu}m$(ZPLW-207) is obtained. Finally, the waveguides of line, bend and branch type are successfully fabricated.

  • PDF

Brassiere sizing system applying loss function -Centering on elderly women- (손실함수를 이용한 브래지어 치수 규격 설정에 관한 연구)

  • 이경화;최혜선
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.268-279
    • /
    • 1995
  • The purpose of this study is to suggest a brassiere sizing chart for elderly women. It is found that there is no direct linear relationship between cup size and under bust girth from the analsis of breast measurements. These 2 factors(under bust girth and cup size) were chosen as 2 axes of brassiere size chart. A loss function was used to determined intervals of bust girth and cup size of size chart, because the loss function introduces the concept of frequency to size chart for better customer's satisfaction. From the dual distribution table whose intervals had been determinde by a loss function. The 15 sizes, which had more than 2% of appearance were suggested for brassiere size chart. The suggested brassierc sizes covened 87.6% of all subjects. Considering that KS brassiere size thart consisting of 32 sizes covers 88.5%, the suggested brassiere size chart would be considered quite feasible. Also is suggested supply reference measurement chart relevant to brassiere manufacturing for 10 most frequent sizes.

  • PDF

The Development on the Estimate method for the Cost-Effect Analysis of the Electrical Safety Management (전기안전 업무의 비용효과 분석을 위한 전기화재 손실비용 추정방법 개발)

  • Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.349-352
    • /
    • 2015
  • This paper estimates electrical fire damage cost-effect to analyze electrical safety efficiency by applying a cost-benefit analysis method for analyzing the efficiency of a business public interest. Electrical fire loss statistics data was presented as direct costs and casualties, including deaths due to an electrical fire, this paper adds overhead "Incidental Cost of Accidents to the Employer" by W. H. Heinrich was applied to estimate the cost of economic loss. Also wounded, including the loss of human deaths by referring to the car accident insurance claims costs and human development estimated the losses caused by an electrical fire. And to perform a cost-benefit analysis of the electrical safety as a result of future work. In this paper, the economic effect of the electric field of safety and public interest work to systematically presented.

Performance prediction and measurement of the barrier (합성수지 방음벽의 성능예측 및 평가)

  • 박진규;김관주;정환익;김상헌;최상석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.718-723
    • /
    • 2004
  • The insertion loss of a noise barrier comes from the effects of diffraction, transmission loss, absorption coefficient and attenuation by direct propagation. The noise level after the noise barrier, differs reatly from the diffraction on the upper part of the barrier. Maekawa, furze and Anderson presented a empirical formula for calculating the diffraction of a semi infinte screen shaped noise barrier. In this syudy, Noise reduction performance software was developed for the proper design and assessment of new plastic barrier . Predicted sound pressure level from using the software is compared with the site-measurement results to verify the noise reduction performance and feasibility of prediction software for insertion loss of noise barrier.

  • PDF