• Title/Summary/Keyword: Direct Loss

Search Result 907, Processing Time 0.028 seconds

A Simplified Procedure for Performance-Based Design

  • Zareian, Farzin;Krawinkler, Helmut
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.13-23
    • /
    • 2007
  • This paper focuses on providing a practical approach for decision making in Performance-Based Design (PBD). Satisfactory performance is defined by several performance objectives that place limits on direct (monetary) loss and on a tolerable probability of collapse. No specific limits are placed on conventional engineering parameters such as forces or deformations, although it is assumed that sound capacity design principles are followed in the design process. The proposed design procedure incorporates different performance objectives up front, before the structural system is created, and assists engineers in making informed decisions on the choice of an effective structural system and its stiffness (period), base shear strength, and other important global structural parameters. The tools needed to implement this design process are (1) hazard curves for a specific ground motion intensity measure, (2) mean loss curves for structural and nonstructural subsystems, (3) structural response curves that relate, for different structural systems, a ground motion intensity measure to the engineering demand parameter (e.g., interstory drift or floor acceleration) on which the subsystem loss depends, and (4) collapse fragility curves. Since the proposed procedure facilitates decision making in the conceptual design process, it is referred to as a Design Decision Support System, DDSS. Implementation of the DDSS is illustrated in an example to demonstrate its practicality.

A Study on Education Service Quality's Expected Loss Evaluation Model with Potential Customer Satisfaction Improvement Index (잠재적고객요구개선지수를 이용한 교육서비스품질 기대손실평가 모형에 관한 연구)

  • Chang, Yong-Hyuk;Cho, Yu-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.2
    • /
    • pp.15-23
    • /
    • 2019
  • Among service industries of knowledge based economic era, the roles of educational service field are becoming more important and standard of educational service makes a direct effect on economic development and social growth. Therefore, accurate measurement of service quality is the most important assignment and the measurement of the service quality remains difficult assignment. So, this researcher classified quality attributes applying weighted value and found potential satisfaction level(PSL) and potential customer demand improvement index(PCDI) for trainees participating in national manpower business so as to suggest measurement of service quality and easiness of use and then, calculated satisfaction position and opportunity cost by quality factor with Taguchi's loss fraction. And, improvable satisfaction level was measured, opportunity cost by degree of customer dissatisfaction was quantitatively measured, and a model that can indicate with economic factors was suggested. In addition, methodology of measuring quality cost that can be reduced by quality improvement and direction of strategic decision-making for deciding items to be improved preferentially were suggested with qualitative index that can indicate the degree of customers' dissatisfaction by loss.

Bone loss-related factors in tissue and bone level dental implants: a systematic review of clinical trials

  • Mortazavi, Hamed;Khodadoustan, Amin;Kheiri, Aida;Kheiri, Lida
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.3
    • /
    • pp.153-174
    • /
    • 2021
  • Dental implants are popular for dental rehabilitation after tooth loss. The goal of this systematic review was to assess bone changes around bone-level and tissue-level implants and the possible causes. Electronic searches of PubMed, Google Scholar, Scopus, and Web of Science, and a hand search limited to English language clinical trials were performed according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines up to September 2020. Studies that stated the type of implants used, and that reported bone-level changes after insertion met the inclusion criteria. The risk of bias was also evaluated. A total of 38 studies were included. Eighteen studies only used bone-level implants, 10 utilized tissue-level designs and 10 observed bone-level changes in both types of implants. Based on bias assessments, evaluating the risk of bias was not applicable in most studies. There are vast differences in methodologies, follow-ups, and multifactorial characteristics of bone loss around implants, which makes direct comparison impossible. Therefore, further well-structured studies are needed.

Fast transport with wall slippage

  • Tang, Zhipeng;Zhang, Yongbin
    • Membrane and Water Treatment
    • /
    • v.12 no.1
    • /
    • pp.37-41
    • /
    • 2021
  • This paper presents the multiscale calculation results of the very fast volume transport in micro/nano cylindrical tubes with the wall slippage. There simultaneously occurs the adsorbed layer flow and the intermediate continuum fluid flow which are respectively on different scales. The modeled fluid is water and the tube wall is somewhat hydrophobic. The calculation shows that the power loss on the tube no more than 1.0 Watt/m can generate the wall slippage even if the fluid-tube wall interfacial shear strength is 1 MPa; The power loss on the scale 104 Watt/m produces the volume flow rate through the tube more than one hundred times higher than the classical hydrodynamic theory calculation even if the fluid-tube wall interfacial shear strength is 1 MPa. When the wall slippage occurs, the volume flow rate through the tube is in direct proportion to the power loss on the tube but in inverse proportion to the fluid-tube wall interfacial shear strength. For low interfacial shear strengths such as no more than 1 kPa, the transport in the tube appears very fast with the magnitude more than 4 orders higher than the classical calculation if the power loss on the tube is on the scale 104 Watt/m.

Review on Case Reports of Korean Medical Treatments for Sudden Sensory Neural Hearing Loss (돌발성 난청의 한방치료 치험례에 대한 고찰)

  • Lee, Yu Ri;Kim, Kyung Soon;Choi, Hong Sik;Kim, Seung Mo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.62-69
    • /
    • 2018
  • This study aimed to review case reports of Korean medical treatments for sudden sensory neural hearing loss published in Korea from 1980 to 2016. We searched sudden sensory neural hearing loss through 6 major Korean web article search engines and search period was January 1980 to September 2016. Two researchers included studies on sudden hearing loss, clinical studies on korean medical treatments, and excluded in vivo studies, in vitro studies, non-original studies, published abstracts only, and studies not published in Korean or English. 19 articles were included in this study from 63 articles. Only one case report used Korean medical treatment alone. The most tools for treatment were acupunture, herbal medicine, pharmacopunture, moxibustion, cupping treatment and laser therapy. Most acupoints used in the treatment is SI19(聽宮). When patients got treated sooner, recovery rate was better. There was no direct relationship between recovery rate and degree of hearing loss. This study suggests that more research about sudden sensory neural hearing loss is needed in the future.

Assessing the Effectiveness and Safety of Direct-acting Antiviral Treatment in Korean Patients with Hepatitis C Virus Genotype 1b or 2 at a Tertiary Care Hospital

  • Park, Mi Seon;Yang, Young-Mo;Park, Ki Hyun;Yoon, Hyonok;Kim, Ju Sin;Choi, Eun Joo
    • Korean Journal of Clinical Pharmacy
    • /
    • v.32 no.3
    • /
    • pp.191-203
    • /
    • 2022
  • Background: Direct-acting antivirals are recommended for the treatment of chronic hepatitis C virus in Korea. However, evaluation of direct-acting antiviral regimens in a real-world setting is limited. The aims of this study were to investigate the effectiveness and safety of direct-acting antiviral treatment in Korean patients infected with chronic hepatitis C virus genotype 1b or 2 at a tertiary care hospital. Methods: This was a retrospective study conducted with patient data obtained between August 2015 and August 2019 at Jeonbuk National University Hospital. The primary effectiveness endpoint was sustained virological response 12 weeks post-treatment (SVR12) via intention-to-treat (ITT) and modified intention-to-treat (mITT) analyses. Results: Of the 270 patients, 47.0% were infected with genotype 1b and 53.0% with genotype 2. ITT analysis revealed that SVR12 was achieved in 78.9% of all patients, 77.2% in genotype 1b patients, and 80.4% in genotype 2 patients. Of the 21.1% of all patients who did not achieve SVR12, the majority of treatment failures were non-virologic failures (19.7%). mITT analysis revealed that SVR12 was achieved in 98.2% of all patients, 98.0% in genotype 1b patients, and 98.3% in genotype 2 patients. Almost half of all patients experienced one or more adverse events (43.3%), leading to 2.6% discontinuing scheduled treatment. The most common adverse event was anemia. Conclusions: Direct-acting antiviral-based treatment regimens showed high effectiveness and safety. Non-virological factors, such as premature treatment discontinuation due to adverse events or loss of follow-up, were the major disruptors in achieving SVR12.

Design of Optimal Capacity Coefficients of Flow Control Valves in the Hoist Hydraulic System Using the Complex Method (콤플렉스법에 의한 호이스트 유압회로 유량제어밸브의 최적유량계수 설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, two pilot operated check valves, two flow control valves. The capacity coefficients of flow control valves should be adjusted for the hoist to operate at moderate speed and minimize the hydraulic energy loss. However, it is difficult to adjust the four capacity coefficients of flow control valves by trial and error for optimal operation. The steady state model of the hoist hydraulic system is derived and the optimal capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Comparison of Efficiency for Different Switching Tables in Six-Phase Induction Motor DTC Drive

  • Taheri, Asghar;Rahmati, Abdolreza;Kaboli, Shahriyar
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, different switching tables proposed for the Direct Torque Controlled (DTC) of a six-phase induction machine are simulated and implemented. A six-phase induction motor has 64 space voltage vectors which result in increased complexity in the selecting of inverters switching. The unsuitable selection of a switching table leads to large harmonics especially at low speed and it also reduces drive efficiency. A six-phase induction machine has large zero sequence harmonic currents of the order $6{\kappa}{\pm}1$. These harmonic currents are varied in various techniques. Decreasing this loss is essential in a six-phase induction machine. The main purpose of this paper is to improve the ST-DTC of six-phase induction machines to reduce the voltage and current harmonics and the torque pulsation. Selecting a suitable method for minimizing these harmonics is very important.

High-Speed Signaling in SDARM Bus Interface Channels : Review

  • Park, Hong-June;Sohn, Young-Soo;Park, Jin-Seok;Bae, Seung-Jun;Park, Seok-Woo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.50-69
    • /
    • 2001
  • Three kinds of high-speed signaling methods for synchronous DRAM (SDRAM) bus interface channels (PC-133, Direct-Rambus, and SSTL-2) were analyzed in terms of the timing budget and the physical transmission characteristics. To analyze the SDRAM bus interface channels, loss mechanisms and the effective characteristic impedance method were reviewed and the ABCD matrix method was proposed as an analytic and yet accurate method. SPICE simulations were done to get the AC responses and the eye patterns of the three SDRAM bus interface channels for performance comparisons. Recent progress and future trend for SDRAM bus interface standards were reviewed.

  • PDF

Vibration and Damping Characteristics of Viscoelastically Damped Sandwich Plates (점탄성층이 샌드위치된 복합적층판의 진동감쇠 특성)

  • 김재호;박태학;신현정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2252-2263
    • /
    • 1993
  • The purpose of this study is to verify the vibration and damping characteristics of elastic-viscoelastic-elastic structures, theoretically and experimentally. The forth-order differential equations of motion are derived for the transverse vibration of three-layered plates with viscoelastic core layer. The equations consider both transverse displacements of the constraining layer and the bare base plate as variable and account for the effect of the transverse normal strain and the shear strain of viscoelastic core layer on the vibration of the plates. Finite difference analysis of the equations and experimental measurements are performed on the three-layered plates of completely free boundary condition. Comparative investigations on the theory and the results of direct frequency analysis of NASTRAN are carried out on the same structures.