• Title/Summary/Keyword: Direct Detection

Search Result 926, Processing Time 0.028 seconds

Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement (직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구)

  • Yeo, Jin-Hee;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.

A rapid and direct method for half value layer calculations for nuclear safety studies using MCNPX Monte Carlo code

  • Tekin, H.O.;ALMisned, Ghada;Issa, Shams A.M.;Zakaly, Hesham M.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3317-3323
    • /
    • 2022
  • Half Value Layer calculations theoretically need prior specification of linear attenuation calculations, since the HVL value is derived by dividing ln(2) by the linear attenuation coefficient. The purpose of this study was to establish a direct computational model for determining HVL, a vital parameter in nuclear radiation safety studies and shielding material design. Accordingly, a typical gamma-ray transmission setup has been modeled using MCNPX (version 2.4.0) general-purpose Monte Carlo code. The MCNPX code's INPUT file was designed with two detection locations for primary and secondary gamma-rays, as well as attenuator material between those detectors. Next, Half Value Layer values of some well-known gamma-ray shielding materials such as lead and ordinary concrete have been calculated throughout a broad gamma-ray energy range. The outcomes were then compared to data from the National Institute of Standards and Technology. The Half Value Layer values obtained from MCNPX were reported to be highly compatible with the HVL values obtained from the NIST standard database. Our results indicate that the developed INPUT file may be utilized for direct computations of Half Value Layer values for nuclear safety assessments as well as medical radiation applications. In conclusion, advanced simulation methods such as the Monte Carlo code are very powerful and useful instruments that should be considered for daily radiation safety measures. The modeled MCNPX input file will be provided to the scientific community upon reasonable request.

The Effectiveness of Environmental Management through Environmental Surveillance (환경감시를 통한 환경관리의 효과)

  • Mi Hyang Lee;Jae Yeun Kim;Sang Ha Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.557-561
    • /
    • 2023
  • This study aims to assess how effective environmental management can be accomplished through monitoring of environmental conditions in patient discharge rooms within healthcare facilities through direct observation and the use of fluorescent markers. From March to July 2013, this study evaluated 448 check-out beds in wards and intensive care units before and 494 after intensive environmental monitoring activities. The collected data were analyzed using the SPSS 21.0 program. According to the study's findings, direct observation increased from 95.2% prior to the implementation of intensive environmental monitoring activities to 98.9% following the implementation, which was statistically significant. The non-detection rate of fluorescent markers exhibited an increase from 96.1% prior to the commencement of intensive environmental monitoring activities to 98.0% following their implementation. However, it should be noted that this observed increase was not deemed statistically significant. In light of the results of this research, it is imperative to evaluate the effectiveness of environmental management by employing a variety of assessment methods, including direct observation and fluorescent markers.

Visual detection of porcine circovirus 2 by loop-mediated isothermal amplification (LAMP) with hydroxynaphthol blue dye (육안 판독 등온증폭법을 이용한 돼지 써코바이러스 2형 신속 진단법)

  • Kong, Ho-Chul;Kim, Eun-Mi;Jeon, Hyo-Sung;Kim, Ji-Jung;Kim, Hee-Jung;Park, Yu-Ri;Kang, Dae-Young;Kim, Young-Hwa;Park, Jun-Cheol;Lee, Chang-hee;Yeo, Sang-Geon;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.3
    • /
    • pp.145-153
    • /
    • 2015
  • In this study, we developed a loop-mediated isothermal amplification (LAMP) with hydroxynaphtol blue dye (HNB) for rapid and direct visual detection of porcine circovirus 2 DNA with high sensitivity and specificity. The LAMP was completed in 40 min at $63^{\circ}C$, and the results of the LAMP can be confirmed by naked eye without any detection process. The sensitivity of the LAMP was 10-fold higher than that of the commercial PCR (cPCR) and real time PCR (rPCR) previously reported. In clinical application, the PCV2 detection rate of the LAMP was the same on porcine tissue samples (75.0%, 36/48) between porcine blood samples (75.0%, 39/52). The PCV2 detection rate (75.0%) of LAMP was higher than those of the cPCR and rPCR (67.3%, 35/52) in blood samples. In conclusion, the LAMP developed in the study could be an useful alternative method for the detection of PCV2 in the swine disease diagnostic laboratories.

Selective Detection of Salmonella sp. and Salmonella Typhimurium in Meat by Polymerase Chain Reaction (PCR을 이용한 육류 내 Salmonella sp. 및 Salmonella Typhimurium 분리 검출)

  • Joo, Jong-Won;Hong, Kyung-Pyo;Kim, Yong-Hui;Cho, Sang-Buem
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.2
    • /
    • pp.295-300
    • /
    • 2009
  • The specificity and sensitivity of oligonucleotide primers were examined for the rapid detection of Salmonella in meat samples. The oligonucleotide primers used in this study were designed with the modification of mdh and invA sequence in the chromosome of Salmonella Typhimurium. Through the subsequent analysis of the specificity and sensitivity of the primers, two types of oligonucleotide primers, SLM1 and SLT4 were selected for the detection of Salmonella genus specific and S. Typhimurium species specific, respectively. The lowest detection limit of each primer was represented as 1 cell per reaction when reacted with a prepared DNA solution. The detection efficiency of the two primers was analysed with beef and pork samples intentionally contaminated with a mixture of Salmonella culture, and three preparation methods -, namely direct reaction after extraction, enrichment after extraction, and DNA extraction after enrichment for PCR reaction, - were also compared. No differences were found in the results according to meat sources and preparation methods.

  • PDF

High-risk Human Papillomavirus Genotype Detection by Electrochemical DNA Chip Method

  • Chansaenroj, Jira;Theamboonlers, Apiradee;Chinchai, Teeraporn;Junyangdikul, Pairoj;Swangvaree, Sukumarn;Karalak, Anant;Takahashi, Masayoshi;Nikaido, Masaru;Gemma, Nobuhiro;Poovorawan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1151-1158
    • /
    • 2012
  • High-risk human papillomavirus (HPV) genotypes are the major cause of cervical cancer. Hence, HPV genotype detection is a helpful preventive measure to combat cervical cancer. Recently, several HPV detection methods have been developed, each with different sensitivities and specificities. The objective of this study was to compare HPV high risk genotype detection by an electrochemical DNA chip system, a line probe assay (INNO-LiPA) and sequencing of the L1, E1 regions. A total of 361 cervical smears with different cytological findings were subjected to polymerase chain reaction-sequencing and electrochemical DNA chip assessment. Multiple infections were found in 21.9% (79/361) of the specimens, most prevalently in 20-29-year olds while the highest prevalence of HPV infection was found in the 30-39-year age group. The most prevalent genotype was HPV 16 at 28.2% (138/489) followed by HPV 52 at 9.6% (47/489), with the other types occurring at less than 9.0%. The electrochemical DNA chip results were compared with INNO-LiPA and sequencing (E1 and L1 regions) based on random selection of 273 specimens. The results obtained by the three methods were in agreement except for three cases. Direct sequencing detected only one predominant genotype including low risk HPV genotypes. INNO-LiPA identified multiple infections with various specific genotypes including some unclassified-risk genotypes. The electrochemical DNA chip was highly accurate, suitable for detection of single and multiple infections, allowed rapid detection, was less time-consuming and was easier to perform when compared with the other methods. It is concluded that for clinical and epidemiological studies, all genotyping methods are perfectly suitable and provide comparable results.

Detection of Human Papillomavirus in Male and Female Urine by Electrochemical DNA Chip and PCR Sequencing

  • Nilyanimit, Pornjarim;Wanlapakorn, Nasamon;Niruthisard, Somchai;Pohthipornthawat, Natkrita;Karalak, Anant;Laowahutanont, Piyawat;Phanuphak, Nittaya;Gemma, Nobuhiro;Poovorawan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5519-5525
    • /
    • 2013
  • Background: Cervical cancer is the second most common cancer in Thai women after breast cancer. Currently, the Papanicolaou (Pap) smear is the recommended procedure for cervical cancer screening in Thailand, but only a relatively small percentage of women follow this screening program. An alternative method to detect HPV genotypes associated with cervical cancer is self-sampling of urine, which is a more widely accepted method. Our study aimed to evaluate the prevalence of HPV in Thai women using urine and cervical swabs and prevalence of HPV in Thai men using urine samples. Materials and Methods: Tumorigenic HPV detection was accomplished by electrochemical DNA chip and PCR/direct sequencing. In addition to HPV prevalence, we report the concordance between different methods and sample types. One-hundred and sixteen women and 100 men were recruited. Histological examination revealed normal cytology in 52 women, atypical squamous cells of undetermined significance (ASCUS) in 9, low-grade squamous intraepithelial lesions (LSIL) in 24, and high-grade squamous intraepithelial lesions (HSIL) in 31. One-hundred men were classified as heterosexuals (n=45) and homosexuals (n=55). Results: The most prevalent HPV genotype in our study was HPV16. The HPV detection rate was generally lower in urine samples compared with cervical samples. Overall, there was good agreement for the detection of carcinogenic HPV from female cervical samples between the DNA chip and PCR/sequencing, with 88.8% total agreement and a kappa value of 0.76. In male urine samples, the level of agreement was higher in heterosexuals compared with homosexuals. Conclusions: Further improvement is required to increase an overall yield of HPV DNA detection in urine samples before clinical application of a urine-based HPV screening program. The electrochemical DNA chip test is a promising technique for carcinogenic HPV detection.

A Nucleic Acid Amplification Tests for Reliable HCV RNA Detection Method for Plasma-Derived Products (핵산증폭시험을 이용한 혈장분획물질에서 HCV RNA 검출)

  • Hong, Seung-Hee
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.293-298
    • /
    • 2008
  • HCV is transmitted via various plasma derived products. Current methods to detect hepatitis C virus (HCV) are based on its antibody detection in the donated blood and plasma. Viral contamination can potentially escape such detection during the window period of infection, when no antibody is present or the level of antibody is too low to detect. It is trying to application of nucleic acid amplification tests (NAT) for the direct detection of HCV. The objective of this study was to develop a reliable NAT for the HCV RNA detection from plasma-derived products. The most useful primers was selected for NAT among 5 sets of primers. We have also found that QIAamp viral RNA isolation kit was the most efficient for HCV RNA isolation. The highest sensitivity and specificity was appeared in $48^{\circ}C$ annealing temperature and 30 pmol of primers. With a spiking of HCV to albumin, immunoglobulins and coagulation factors, NAT can detect up to 100 IU/ml. Meanwhile, COBAS amplicor HCV 2.0 afforded a lower sensitivity in high concentrated intramuscular immunoglobulins to below 500 IU/ml. Our results suggested that NAT appears to be a highly sensitive and specific method for HCV RNA detection in plasma-derived products.

Comparative Analysis of Freshwater Fish Species in Civilian Control Zone in South Korea: A Comparison between Direct Survey Results and Indirect Assessment via eDNA (우리나라 민간인통제구역 내 수계 어류에 대한 비교분석: 직접조사 결과와 eDNA를 통한 간접조사 결과 비교)

  • Soon-Jae Eum;Naeyoung Kim;Min-A Seol;Ji Young Kim
    • Korean Journal of Ichthyology
    • /
    • v.35 no.4
    • /
    • pp.224-235
    • /
    • 2023
  • South Korea is the only divided nation globally, marked by a military demarcation line establishing demilitarized and civilian control zones, ensuring national security. Consequently, these areas exhibit relatively minimal ecological disruption compared to other regions. However, the threat to safety persists due to the presence of unexploded ordnances and landmines, imposing significant constraints on ecological research. To address this, we conducted a comparative study utilizing eDNA analysis as a supplementary and alternative approach within three points of the "Road of Peace" - Inje, Yanggu, and Hwacheon courses, located within the civilian control zone. Direct surveys and indirect eDNA sampling were carried out in May, July, and September of 2022. Genetic material obtained from the samples underwent amplification, library preparation, MiSeq sequencing, and subsequent ASV generation for indirect analysis. These results were then compared with the findings of direct surveys. Our findings revealed the detection of eDNA for both observed species at the Yanggu-1 point, and for two out of four species at Yanggu-2. Hwacheon-1 displayed the detection of eDNA for one out of one observed species, whereas Hwacheon-2 yielded seven out of twelve, Hwacheon-3 showed four out of six, and all one observed species at Hwacheon-4 exhibited eDNA detection. Consequently, approximately 69% of the fish species identified through direct surveys were confirmed by indirect eDNA analysis. It is necessary to verify if certain fish species, such as the continental trout and catfish, have genetic information registered in the NCBI database. Additionally, it is believed that further marker development research utilizing different genetic sequences is essential. Given the limitations imposed by the hazardous nature of the surveyed civilian control zone, eDNA analysis proves to be a suitable supplement for fish research in the area.

Differencing Multiuser Detection Using Error Feedback Filter for MIMO DS-UWB System in Nakagami Fading Channel

  • Kong, Zhengmin;Fang, Yanjun;Zhang, Yuxuan;Peng, Shixin;Zhu, Guangxi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.10
    • /
    • pp.2601-2619
    • /
    • 2012
  • A differencing multiuser detection (MUD) method is proposed for multiple-input multiple-output (MIMO) direct sequence (DS) ultra-wideband (UWB) system to cope with the multiple access interference (MAI) and the computational efficiency in Nakagami fading channel. The method, which combines a multiuser-interference-cancellation-based decision feedback equalizer using error feedback filter (MIC DFE-EFF), a coefficient optimization algorithm (COA) and a differencing algorithm (DA), is termed as MIC DFE-EFF (COA) with DA for short. In the paper, the proposed MUD method is illuminated from the rudimental MIC DFE-EFF to the advanced MIC DFE-EFF (COA) with DA step by step. Firstly, the MIC DFE-EFF system performance is analyzed by minimum mean square error criterion. Secondly, the COA is investigated for optimization of each filter coefficient. Finally, the DA is introduced to reduce the computational complexity while sacrificing little performance. Simulations show a significant performance gain can be achieved by using the MIC DFE-EFF (COA) with DA detector. The proposed MIC DFE-EFF (COA) with DA improves both bit error rate performance and computational efficiency relative to DFE, DFE-EFF, parallel interference cancellation (PIC), MIC DFE-EFF and MIC DFE-EFF with DA, though it sacrifices little system performance, compared with MIC DFE-EFF (COA) without DA.