• Title/Summary/Keyword: Direct Vibration Method

Search Result 294, Processing Time 0.024 seconds

Estimation of Vibration Source and Sound Radiation of a Refrigerator Fan by using Measured Acceleration Signals (가속도 측정신호를 이용한 냉장고 홴의 진동원과 방사소음의 예측)

  • Jung, Byung-Kyoo;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.834-841
    • /
    • 2011
  • Obtaining the real exciting force is important for the analysis of structural vibration or sound radiation to represent the actual condition. But in most cases, it is so difficult to get the actual force signals by direct measurement using sensors due to complex geometry. This paper suggests advanced source identification method which can be applied to the prediction of radiated noise considering correlations between measured signals. This method was implemented to the identification of the fan force in the refrigerator. The analysis of structural vibration and radiated noise caused by the fan force was also performed. The comparison between predicted SPL and measured SPL of the radiated noise by the refrigerator fan showed good agreement.

An Experimental Study on the Dynamic Load Characteristics of Surface Mount Device(SMD) (칩마운트 (SMD) 장비의 동하중(動荷重) 발생특성에 관한 실험적 연구)

  • Baek, Jae-Ho;Lee, Hong-Ki;Kim, Kang-Boo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1913-1917
    • /
    • 2000
  • SMD Equipment convey an electronic parts at high speed, then assemble parts into a circuit board, and it develop a long time-duration dynamic force to be caused by moving mass. Vibration problem to be caused by SMD Equipment have an effect on micro-meter level's precision production process, directly, and dynamic stability of building. In the cause of quantitatively access about its vibration problem, input information(or data) of structure dynamic analysis need accuracy information of dynamic load. Determination of Dynamic load is various kinds of method using experimental and theory. In this paper, we got dynamic load using direct measurement method. We expect that an study on the dynamic load characteristic of SMD can be used to Equipment development of low level vibration and basis information of structure dynamic analysis.

  • PDF

The Reduction of Harmonic Dynamic Response of Plate Structure Using Continuum Design Sensitivity Analysis (연속법에 의한 설계민감도를 이용한 판구조물의 조화진동저감)

  • 이재환;이광한
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.27-34
    • /
    • 1996
  • In this paper, design sensitivity of vibration displacement and acceleration is computed and design sensitivity, the derivative information of responses with respect to design perameters, is used as a design guidance tool to reduce the vibration. First, the harmonic vibration analysis of deck and simplified ship structures is performed by finite element method and secondly continuum disign sensityivity for excessive dynamic response is computed by continuum method. Both the direct and modal frequency response methods for the finite element analysis are adopted. Sensitivities of structural components such as upper plate, side wall, bilge, bottom plate are compared and the reductionof vibration is obtained by the proper increase of thickness of each component.

  • PDF

Acoustic characteristics of a loudspeaker obtained by vibration and acoustic analysis (진동/음향 해석에 의한 스피커의 음향특성 연구)

  • Kim, Jung-Ho;Kim, Jun-Tai;Kim, Jin-Oh;Min, Jin-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1742-1756
    • /
    • 1997
  • The acoustic characteristics of a direct radiator type loudspeaker has been studied in this paper. The natural modes of the speaker cone vibration analyzed numerically by the finite element method have been verified by comparing them with experimental results. The so-ap-proved finite-element model has been used to calculate the vibration response of the cone excited by the voice coil. The vibration displacement of the speaker cone paper has been converted into the vibration velocity and used as a boundary condition for the acoustic analysis. The frequency characteristics, directivity, and sound pressure distribution of the loudspeaker have been calculated by the boundary element method. The numerical results have been verified by the experiments carried out in an anechoic chamber. The variations of the acoustic characteristics due to the changes of some design parameter values can be examined using the numerical model.

Vibration Analysis of Three-Dimensional Piping System by Transfer Matrix Method (전달행렬법을 이용한 3차원 파이프 계의 진동해석)

  • 이동명
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.6
    • /
    • pp.110-116
    • /
    • 1998
  • For the vibration analysis of 3-dimensional piping system containing fluid flow, a transfer matrix method is presented. The fluid velocity and pressure were considered, that coupled to longitudinal and flexural vibrations. Transfer matrices and point matrices were derived from direct solutions of the differential equations of motion of pipe conveying fluids, and the variations of natural frequency with flow velocity for 3-dimensional piping system were investigated.

  • PDF

Prediction of Sound Radiation Power from Coupled Structures using SEA (SEA 법에 의한 결합구조물의 음향방사파워 예측)

  • 오재응
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1987.11a
    • /
    • pp.24-30
    • /
    • 1987
  • SEA method have been developed for prediction sound radiation power from vibration of machinery. In this study, sound radiation power was predicted from coupled structures by transmission of vibration, which composed of two plates welded at right angle. The predicted sound radiation power is agreement within 2 or 3 dB on octave band comparing with values obtained from direct measurements. Also, in order to prove the validity of this method in changes of sound radiation power associated with modifications to structures, rubber pad stuck on a plate. This result is agreement approximately within 3 or 5 dB.

  • PDF

Comparison of the Insertion Loss Results of Semi-infinite Plane Screen by the Analytical Method and Boundary Element Method (반무한 방음벽의 삽입손실의 이론과 BEM해석에 의한 결과치 비교)

  • 김문섭;김관주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.25-31
    • /
    • 1995
  • 본 연구는 방음벽의 성능예측을 위해 BEM의 접근 방법을 시도하였으며 범용 음향 소프트웨어인 Sys-noise 5.2의 direct collocation bem을 사용하여 반무한 평면 방음벽에 대한 해석을 수행하였으며, 그 결과를 검증하기 위해 Maekawa에 의한 근사해와 해석적 점근해에 비교하였다. 또한, 수음점이 방음벽으로부터 떨어진 거리, 방음벽의 폭, 방음벽의 높이에 따른 삽입손실을 계산하였고, 방음벽에 흡음처리를 한 경우와 방음벽상단의 형상변화에 따른 삽입손실의 변화를 계산하였다.

  • PDF

Partial Field Decompositon Using Beamforming Method Under Reflective Condition (반사면이 존재하는 환경에서 빔포밍 방법을 이용한 부분 음장 재구성)

  • 선종천;강연준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.730-734
    • /
    • 2003
  • A beamforming method is a kind of spatial filter that focus the amy's signal capturing abilities in a desired direction. In this paper, we detect the location of a source under reflective condition using the multi-dimensional MUSIC algorithm then, we can iud the image source locations from the experimental geometry, and we reconstruct the partial fields for direct wave and reflected wave by using Adaptive nulling algorithm. Numerical simulations are performed to verify its performance under various conditions.

  • PDF

A Study on the Korea Industrial Standardization of ISO 9053 (공기흐름저항(ISO 9053)의 KS 규격 제정에 관한 연구)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.984-985
    • /
    • 2004
  • The ISO 9053, acoustics - materials for acoustical applications - determination of airflow resistance was reviewed in order to make it as a KS and the basic contents were introduced. The measurement apparatus according to ISO 9053 were made and tested.

  • PDF

Extraction of rational functions by forced vibration method for time-domain analysis of long-span bridges

  • Cao, Bochao;Sarkar, Partha P.
    • Wind and Structures
    • /
    • v.16 no.6
    • /
    • pp.561-577
    • /
    • 2013
  • Rational Functions are used to express the self-excited aerodynamic forces acting on a flexible structure for use in time-domain flutter analysis. The Rational Function Approximation (RFA) approach involves obtaining of these Rational Functions from the frequency-dependent flutter derivatives by using an approximation. In the past, an algorithm was developed to directly extract these Rational Functions from wind tunnel section model tests in free vibration. In this paper, an algorithm is presented for direct extraction of these Rational Functions from section model tests in forced vibration. The motivation for using forced-vibration method came from the potential use of these Rational Functions to predict aerodynamic loads and response of flexible structures at high wind speeds and in turbulent wind environment. Numerical tests were performed to verify the robustness and performance of the algorithm under different noise levels that are expected in wind tunnel data. Wind tunnel tests in one degree-of-freedom (vertical/torsional) forced vibration were performed on a streamlined bridge deck section model whose Rational Functions were compared with those obtained by free vibration for the same model.