• Title/Summary/Keyword: Diplophonia

Search Result 4, Processing Time 0.021 seconds

Clinical utility of auditory perceptual assessments in the discrimination of a diplophonic voice (이중음성 판별에 있어 청지각적 평가의 임상적 유용성)

  • Bae, Inho;Kwon, Soonbok
    • Phonetics and Speech Sciences
    • /
    • v.10 no.1
    • /
    • pp.75-81
    • /
    • 2018
  • Diplophonia is generally defined as the perception of more than one fundamental frequency component in a voice. Its perceptual aspect has traditionally been used to evaluate diplophonia because the perceptions can be easily evaluated, but there are limitations in the validity of the reliability of the intra- and inter-raters, examination situation, and variation of voice sample. Therefore, the purpose of this study is to confirm the reliability and accuracy of auditory perceptual evaluation by comparing non-invasive indirect assessment methods (sound waveform and EGG analysis), and to identify their usefulness with diplophonia. A total of 28 diplophonic voices and 39 non-periodic voices were assessed. Three raters assessed the diplophonia by performing an auditory perception evaluation and identifying the quasi-periodic perturbations of the acoustic waveform and EGG. Among the three discrimination methods, intra- and inter-rater reliability, sensitivity, specificity, accuracy, positive likelihood ratio, and negative likelihood ratio were examined, and the McNemar test was performed to compare the discriminant agreement. The accuracy of the auditory perceptual evaluation (86.57%) was not significantly different from that of sound waveform acoustic (88.06%), but it was significantly different from that of EGG (83.33%). The reading time (6.02 s) for the auditory perceptual evaluation was significantly different from that for sound waveform analysis (30.15 s) and EGG analysis (16.41 s). In the discrimination of diplophonia, auditory perceptual evaluation has sufficient reliability and accuracy as compared to sound waveform and EGG. Since immediate feedback is possible, auditory perceptual evaluation is more convenient. Therefore, it can continue to be used as a tool to discriminate diplophonia in clinical practice.

Quasi-periodic waveform analysis for diplophonia (이중음성에 대한 음성파형분석)

  • 홍기환;김미정;정상술
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1993.05a
    • /
    • pp.71-71
    • /
    • 1993
  • Diplophonia is produced by the voice of two separate tones and produced through quasi-periodic variations in the vocal cord vibration. Diplophonia is generally regarded as a symptom of laryngeal pathology. The difference in the vibratory frequency between the vocal cords can be seen in a tension imbalance and a difference in the level of the vocal folds under the special condition such as incomplete glottal closure. So authors have experienced 19 cases of patient with diplophonia for the unilateral vocal cord paralysis, intracordal cysts and other mass lesions. And we analysed the diplophonic voice with peak variability and noise level for the quasi-periodic waveforms and spectrograms pre-and postoperatively.

  • PDF

Diplophonia in Mutational Falsetto : Acoustic Characteristics and Treatment -A Case Report- (이중음성을 보인 변성발성장애 환자 음성의 음향학적 특성 및 치험례 -증 례 보 고-)

  • Lee, Jae-Yol;Lee, Sung-Eun;Lee, Sung-Eun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.47-51
    • /
    • 2004
  • Normally, as a result of increased laryngeal growth, the male voice drops about one octave in pitch level during adolescence. Failure of the voice to drop in pitch is consider to be a clinically significant voice disorder - 'mutational dysphonia'. The aim of this article is to evaluate the changes brought about by voice therapy, using the analysis of the EGG measure from Lx Speech Studio program(Laryngograph Ltd, UK) as well as acoustic, and aerodynamic studies in 18-year-old mutational dysphonia patient. The results from the Lx Speech Studio program demonstrated bimodal distribution of DFx(Hz), DQx(%), QxFx and diplophonic characteristic. After voice therapy combined with manual compression method, the distribution of DFx, DQx, QxFx was changed uniform with a dramatic reduction of higher pitch level. In addition, this finding suggests the EGG measure helps to choice treatment options, monitor the efficacy of therapy, and estimate the prognosis of diseases.

  • PDF

Development of Two-Dimensional Scanning Videokymography for Analysis of Vocal Fold Vibration

  • Wang, Soo-Geun;Lee, Byung-Joo;Lee, Jin-Choon;Lim, Yun-Sung;Park, Young Min;Park, Hee-June;Roh, Jung-Hoon;Jeon, Gye-Rok;Kwon, Soon-Bok;Shin, Bum-Joo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.2
    • /
    • pp.107-111
    • /
    • 2013
  • Objectives : We developed two-dimensional (2D) scanning videokyomography to evaluate the mucosal wave of whole vocal cords in real time to overcome the limit of preexisting stroboscopy and line scanning videokymography which could not evaluate it. Methods : We implemented a continuous light source with high brightness, a high-definition CMOS camera, and capture board for saving the data. We created the software program to analyze the image data from the system. The test of the functionality of the 2D scanning videokymography camera was performed in one of the authors (P.H.J 32 years old male). Vocal cord images were obtained during normal phonation and falsetto phonation. Images were obtained also during cough, diplophonia. Results : The system made it possible to measure objective parameters, including fundamental frequency, amplitude, regularity, mucosal wave, and phase difference, medial and lateral peak, opening versus closing duration related to vocal fold vibration. Simultaneously, it enabled analysis of the whole mucosal wave of the entire vocal fold in real time. 2D scanning videokymography was also effective for evaluating the dynamic status of the vocal fold when the subject phonated aperiodic voice. Conclusion : In conclusion, 2D scanning videokymography can support the analysis of the whole mucosal wave of the entire vocal cord with objective vocal parameters, overcoming the limitations of stroboscopy and previous line scanning videokymography techniques.

  • PDF