• Title/Summary/Keyword: Dioxin-like PCB congener

Search Result 9, Processing Time 0.045 seconds

Evaluation of human exposure to polychlorinated biphenyls using human serum by congener-specific analysis (혈액 중 PCBs 이성질체별 분석에 의한 인체 노출 평가)

  • Park, Hyo-Keun;Lee, Se-Jin;Jin, Guang-Zhu;Kang, Jung-Ho;Baek, Song-E;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.73-85
    • /
    • 2006
  • Blood serum concentrations of polychlorinated biphenyls (PCBs) were measured in employees who worked at a municipal solid waste incinerator (MSWI), members of residential community who lived near the MSWI (<0.3km) and members of residential community lived far from the MSWI (>10 km). Human blood serum samples were analyzed for all PCB congeners using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The mean levels of total PCBs and dioxin-like PCBs in 87 serum samples were 242.77 ng/g lipid and 8.83 TEQ pg/g lipid, respectively. The PCB homologue profiles showed that penta-, hexa-, hepta-chlorinated biphenyls contributed more than 80% of the total PCBs concentration. The most abundant congeners were PCB153, PCB138, PCB180, PCB187, PCB118. A statistical analysis was performed to determine whether there were significant correlations between PCB concentrations and specific variables such as age, gender, smoking habits, occupation, BMI (Body Mass Index) and time of residence. As a result, the age was found to be strongly correlated with serum PCB concentrations. In addition, there were strong correlations between total PCBs and PCB153 (r=0.93, p<.0001), dioxin-like PCBs and PCB118 (r=0.98, p<.0001). So these two congeners are satisfactory indicators for total PCB concentrations and dioxin-like PCBs in human blood respectively.

Assessment of Environmental Pollution for Streams of Andong City in Gyeongbuk Province Using Invertebrate Biomarker and Chemical Residual Analysis (무척추동물 생체지표와 화학잔류량 분석을 통한 경북 안동지역내 하천들의 환경오염 평가)

  • Ryoo Keon-Sang;Choi Jong-Ha;Kim Young-Gyun;Cho Sung-Hwan;Lee Hwa-Sung
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.583-596
    • /
    • 2005
  • Samples of water, soil, and sediment were taken from 10 streams of Andong city in Gyeongbuk province in October 2004. To assess the degree of environmental pollution for each stream site, the chemical analyses of pollutants such as T-N, T-P, COD, heavy metal, organophosphorous and organochlorine pesticides, and dioxin-like PCB congeners were implemented using the standard process tests or the U. S. EPA methods. In addition, biological assessment using insect immune biomarkers was conducted on the same environmental samples to complement the chemical assessment. Except Waya stream (T-N; 2.91 mg/L, T-P; 0.16 mg/L, COD; 14.0 mg/L) with above the environmental quality standards, the T-P and COD concentrations of 9 sites are relatively low. The contents of Pb and Cd in samples taken from each stream were much lower than environmental quality standards. However, in comparison with soil samples of other streams, several times higher concentrations of Pb and Cd were found in locations at Mi, Gilan, Yeonha, and Waya stream sites. Dementon-S-methyl, diazinon, parathion, and phenthoate compounds among organophosphorous pesticides were detected as concentrations of ppb levels, respectively, from soil samples collected in the vicinity of Gilan, Mi, Norim, and Waya stream. On the other hand, 16 organochlorine pesticides and 12 dioxin-like PCB congeners selected in this study were not found in all samples. In particular, considering significant disrupting effects of Waya stream's samples on insect immune capacity, this stream seems to be contaminated with investigated and/or univestigated pollutants in this study.

Analysis of Dioxins in Meat by HRGC/HRMS (HRGC/HRMS를 이용한 국내유통 육류 중 다이옥신류 분석)

  • Choi, Dongmi;Hu, Soojung;Jeong, Jiyoon;Won, Kyungpoong
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.88-93
    • /
    • 2001
  • To measure the levels of dioxins in food selling at local markets, meat was analyzed by high resolution gas chromatography/high resolution ass spectrometry (HRGC/HRMS). The food samples were obtained from 5 large cities of Seoul, Chunchon, Daejon, Kwangju and Busan in Korea. All the samples were minced and extracted with Soxhlet extractor for 18 hours. After extraction, extracts were cleaned up by sulfuric acid impregnated silica gel, purified on a series of silica gel, alumina, carbon column chromatography and then analyzed by HRGC/HRMS. The contaminated levels were calculated as the TEQs by multiplying with the corresponding WHO-TEFs for each congeners. The overall recoveries were ranged from 80% to 153% and the limit of detection was about 0.01 ppt at S/N>3. The levels of PCDD/Fs for beef, pork and chicken were 0.018, 0.008 and <0.001 pgTEQ/g, respectively. In addition, the levels of non-ortho-co-planar PCBs for beef, pork and chicken were 0.008, 0.002 and 0.001 pgTEQ/g, respectively. Among food samples analyzed, chicken showed the lowest level of dioxin-like compounds. Regarding congener pattern, OCDD and PCB #77 were the highest contributing congeners.

  • PDF

Comparison of the elution patterns for polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/Fs) and dioxin-like polychlorinated biphenyls (PCBs) by manual open columns and automatic parallel LC columns (수동 및 자동화 액체 크로마토그래피 칼럼에 의한 PCDDs/Fs 및 다이옥신과 유사한 PCBs의 용출 패턴 비교)

  • Ahn, Yun Gyong;Shin, Jeoung Hwa;Yoo, Sun Young;Khim, Jeehyeong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.13-22
    • /
    • 2005
  • The elution patterns of seventeen 2,3,7,8-substituted PCDDs/Fs and 12 dioxin-like PCBs were studied by both manual open columns and automatic parallel LC columns in cleanup procedure. PCDDs/Fs and non-ortho-PCBs from other mono-ortho-PCBs were separated on automatic LC column, whereas they were not separated on an open manual column. The elution study on two cleanup methods was carried out using the PAR solution of unlabeled congeners and checked the recovery of each congener. Total recoveries of cleanup fractionation were ranged between 61.9 ~ 96.0% for PCDDs/Fs and 70.4 ~ 79.0% for PCBs by manual open columns and 71.8 ~ 104.5% for PCDDs/Fs and 61.3-120.3% for PCBs by automatic parallel LC columns, respectively. Unfortunately, #169-HxCB and 1,2,3,7,8-PeCDD were not separated on DB-5MS capillary column. The ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA method 1613. It is possible to discriminate 1,2,3,7,8-PeCDD and PCB #169 in HRGC/HRMS analysis.

Environmental Pollutants in Streams of Andong District and Insect Immune Biomarker (안동지역 하천의 환경오염물질과 곤충면역 생체지표 분석)

  • Ryoo Keon Sang;Ko Seong-Oon;Cho Sunghwan;Lee Hwasung;Kim Yonggyun
    • Korean journal of applied entomology
    • /
    • v.44 no.2
    • /
    • pp.97-108
    • /
    • 2005
  • Samples of water, soil, and sediment were taken from 10 streams near Andong, Korea in May 2004. To assess the degree of environmental pollution of each stream, chemical pollutants such as total notrogen (T-N), total phosphorus (T-P), chemical oxygen demand (COD), heavy metals, organophosphorus pesticides, organochlorine pesticides, and dioxin-like PCB congeners were analyzed by standard process tests or U.S. EPA methods. In addition, biomarkers originated from insect immune systems of beet armyworm, Spodoptera exigua, were used to analysis of the environmental samples. Except Waya-chun stream showing T-N content of 9.12 mg/L, most streams were contaminated with relatively low levels of overall pollutants in terms of T-N, T-P, and COD, compared to their acceptable environmental levels designated by the Ministry of Environment. Contents of Pb and Cd in samples of each stream were much lower than environmentally permissible levels. However, several times higherconcentrations of Pb and Cd were found in locations at Mi-chun, Kilan-chun, and Hyunha-chun streams, in comparison with other streams. Diazinon, parathion, and phenthoate compounds among organophosphorus pesticides were detected as concentrations of 0.19, 0.40, and $1.13\;{\mu}g/g$, respectively, from soil sample collected in the vicinity of Mi-chun stream. On the other hand, 16 organochlorine pesticides and 12 dioxin-like PCB congeners, known as endocrine disrupting chemicals, selected in this study were not found above the limit of detection. Biomarker analyses using insect immune responses indicated that Waya-chun stream was suspected as exposure to environmental pollutants. Limitation and compensation of both environmental analysis techniques are discussed.

Separation properties of 209 PCB congeners on capillary columns and identification of PCBs congeners in aroclor standards for source identification (오염원 해석을 위한 폴리염화비페닐류(PCBs) 209 이성체의 컬럼별 분리 특성과 Aroclor 표준품의 이성체 확인)

  • Kim, Kyoung-Soo;Kim, Kyeo-Keun;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.352-364
    • /
    • 2006
  • This study was performed to search for useful separation properties and elution orders of three GC columns (DB-1, DB-5MS, SPB-Octyl) for 209 PCBs congeners using M-1668A-0.01X-SET of the AccuStandard Inc.. In addition, to confirm the quantitative peak in peak pattern method, the IUPAC Nos. of PCBs congener peaks were identified with 4 Aroclor standards (Aroclor-1242, 1248, 1254 and 1260). The separation property of dioxin-like PCBs congeners by four columns (DB-1, DB-5MS, SP-2331 and SPB-Octyl) was excellent in SP-2331. DB-1 and SPB-Octyl columns are necessary to use with a column of other types.

Residual Consistency and Interrelationship Estimation of PCDDs, PCDFs, Dioxin-like PCBs in Colostrum of Primipara and Multipara (초산부, 경산부 초유 중 PCDDs, PCDFs, dioxin-like PCBs의 축적수준 및 상관성 평가)

  • We, Sung-Ug;Kim, Ki-Ho;Cho, Yu-Jin;Cho, Bong-Hui;Park, Sang-Ah;Baek, In-Cheon;Kang, Seong-Hoon;Yoon, Cho-Hee;Min, Byung-Yoon
    • Journal of Life Science
    • /
    • v.20 no.7
    • /
    • pp.1078-1085
    • /
    • 2010
  • Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) are bioaccumulative chemicals that are considered to be toxic contaminants based on several epidemiological studies. These chemicals in colostrum were investigated and estimated for their residual consistencies by maternal characteristics like parity and maternal ages. Test subjects were healthy primipara and multipara mothers with a mean age of 31.5 (S.D=3.6) in 2007. Seven isomers of PCDDs, 10 of PCDFs, 4 of non-orthopolychlorinated biphenyls(non-ortho PCBs) and 8 of mono-orthochlorinated polychlorinated biphenyls (mono-ortho PCBs) were analyzed by HRGC/HRMS. From the analyzed data, the mean level of total WHO-TEQs was 9.41 pg TEQ/g lipid, which is significantly lower than the level found in individuals from other countries. The main contributors to the total WHO-TEQs with increasing percentages were 2,3,4,7,8-PeCDF, 1,2,3,7,8-PeCDD and 3,3',4,4',5-PCB (#126), and they accounted for more than 60% of the total WHO-TEQs. PCDFs concentrations and total WHO-TEQs were negatively associated with parity (p<0.05), and maternal age was positively associated with total WHO-TEQs (p<0.01). However, the associations with body mass index (BMI) and fish intake during pregnancy were not significant. These results were suggested that parity and maternal age are an important factor affecting the concentrations of PCDD/DFs and dl-PCBs in these specimens.

Concentrations and Distribution Patterns of PCDDs, PCDFs, DL-PCBs, PBDEs in Sediments from Ulsan Bay (울산만 퇴적물 내 PCDDs, PCDFs, DL-PCBs, PBDEs의 잔류수준과 분포패턴)

  • Baek, Seung-Hong;Lee, In-Seok;Choi, Minkyu;Lee, Boo-Han;Hwang, Dong-Woon;Kim, Sook-Yang;Choi, Hee-Gu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.4
    • /
    • pp.186-194
    • /
    • 2013
  • We investigated the concentrations and distribution patterns of 17 polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs), 12 dioxin-like polychlorinated biphenyls(DL-PCBs) and 24 polybrominated diphenyl ethers(PBDEs) in sediments from Ulsan Bay in Korea. The concentrations of PCDD/Fs, DL-PCBs, and PBDEs in 33 sediment samples ranged from 0.11 to 4.86($1.81{\pm}1.04$) pg $WHO_{2005}$-TEQ $g^{-1}$ dry weight(dw), 0.06 to 44.2($4.02{\pm}7.99$) pg $WHO_{2005}$-TEQ $g^{-1}$ dw, and 2.81 to 63.8($19.4{\pm}13.9$) ng $g^{-1}$ dw, respectively. DL-PCBs had dominant contributions(mean, 88%) of total TEQ concentrations in sediment. The concentrations of target compounds in inner locations were higher than those in outer locations in Ulsan Bay (p<0.05). The dominant contribution of highly chlorinated DD/Fs in sediment was associated with combustion process from industrial complexes. Distribution pattern of DL-PCBs was similar with those of commercial PCB products. BDE209 was a dominant congener in sediment, suggesting high use amount of commercial deca-BDE product in surrounding areas.

Concentration and Gas-particle Partition of PCDDs/Fs and dl-PCBs in the Ambient Air of Ansan Area (안산지역 대기 중 다이옥신 및 dl-PCBs의 오염특성 조사)

  • Heo, Jong-Won;Kim, Dong-Gi;Song, Il-Seok;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.517-532
    • /
    • 2010
  • After establishment of Banwol industrial complex in 1987, Ansan city becomes the largest industrial sector development in Gyeonggi-do, Korea. As the population and industrial activity grow over this region, toxic air pollutants, particularly POPs (Persistent Organic Pollutants) from various emission sources have been major public concerns. Air samples for POPs monitoring were collected at the industrial sites ($A_2$), residential sites ($B_1$, $B_2$), commercial site (C), and rural/remote site (D) of the area of Ansan during 2008 with a prolonged industrial sampling site $A_1$ from 2001 to 2008. All samples were analysed for 2,3,7,8 substituted-polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) and dioxin like polychlorinatd diphenyls (dl-PCBs). In site $A_1$, a steady decline of their concentrations from 2003 to 2008 was observed due to the reinforced emission guideline from waste incinerators. The average concentration of the PCDD/Fs and dl-PCBs ranged between 0.118 pg-TEQ/$m^3$ (rural/remote site D) and 0.532 pg-TEQ/$m^3$ (industrial area $A_2$). These level were generally consistent with previous studies in Gyeonggi-do, while higher than other places. Most of PCDD/Fs congener were partitioned into particle phase, whereas dl-PCBs were partitioned into gas phase. The logarithm of gas-particle partition coefficient $K_P$ of dl-PCBs and PCDD/Fs were well correlated with sub-cooled liquid vapor pressure $P_L$. The slope $m_T$ of log $K_P$ versus log $P_L$ for PCDD/Fs (-1.22) and dl-PCBs (-1.02) in industrial area ($A_2$) were high compared to other residential/commercial area. It suggests that this area was likely influenced by the direct emission source of PCDD/Fs and dl-PCBs. To simulate the partition of PCDD/Fs and dl-PCBs between gas and particle phase, Junge-Pankow model ($P_L$-base) and $K_{oa}$ model were applied. It was found that J-P model was more suitable than the $K_{oa}$ model in this study.