• Title/Summary/Keyword: Diode/diode laser

Search Result 1,020, Processing Time 0.035 seconds

Normal Pregnancy of Mouse Embryos Transferred after Assisted Hatching by a 1.48$\mu\textrm{m}$ Diode Laser (1.48$\mu\textrm{m}$ Diode Laser로 보조 부화처리 후 이식된 생쥐배의 정상임신에 관한 연구)

  • 김은영;이봉경;남화경;이금실;윤산현;박세필;정길생;임진호
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.3
    • /
    • pp.287-292
    • /
    • 1998
  • The objective of this study was to test whether ZP drilling using a 1.48$\mu$m diode laser beam on mouse IVF embryos becomes effective the hatching and normal in vivo development, as a preliminary test for obtaining the additional proof that the 1.48$\mu$m diode laser could be used safely for human applications. The results obtained in this experiment were as follows: when the hatched rates of mouse embryos by laser ZP drilling according to the embryonic stage were examined until 72 hr (in case of blast tocyst: day 4 after IVF) or 120 hr (in case of 4-cell: day 2 after IVF) after treatment, the d data of laser drilled blastocysts (81.8%) was significantly higher than those of control (hatching blastocyst: day 4 after IVF) (54.2%) and laser drilled 4-cell embryos (45.5%) (p<0.05). When the effect of laser drilling on implantation rates following embryo transfer in day 3 synchronized pseudopregnant recipients was examined, the l laser drilled group (48.7%) was slightly higher than that of control group (43.6%). In addition, when the several pregnant mice delivered in two groups were analysed their chromosomal normality and tested reproductive ability, all p pups were presented normal chromosomal number (n=40) and showed normal growth and reproductive ability. Therefore, these results dem-onstrated that ZP drilling using a 1.48$\mu$m diode l laser can increase the embryo hatching and ind duce the normal pregnancy of mouse embryos.

  • PDF

The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System (TDLAS 시스템을 이용한 유해 배기가스의 농도 계측)

  • Cha, Hak-Joo;Kim, Min-Soo;Shin, Myung-Chul;Kim, Se-Won;Chun, Kwang-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

Study on a New ACF Bonding Methods in LCD Module Using a High Power Diode Laser (다이오드레이저를 이용한 디스플레이 모듈 내 이방성 전도 필름(ACF) 접합 기술에 관한 연구)

  • Ryu K. H.;Seon M. H.;Nam G. J.;Kwak N. H.
    • Laser Solutions
    • /
    • v.8 no.3
    • /
    • pp.21-26
    • /
    • 2005
  • A bonding process between tape-carrier package and a glass panel with anisotropic conductive film (ACF) has been investigated by making use of high power diode laser as a heat source for cure. The results from modeling of process and from optical properties of layers showed that heat absorbed from polyimide film surface and ACF layer is dominant source of curing during laser illumination. Laser ACF bonding has better bonding quality than conventional bonding in view of peel strength, flatness, pressure unbalance and processing time. New ACF bonding processes by making use of high power diode laser are proposed.

  • PDF

Treatment of Laryngotracheal Papilloma with 532-nm Diode Laser

  • Shim, Jaehyun;Choi, Soo Jeong;Jung, Kwang-Yoon;Baek, Seung-Kuk
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.190-193
    • /
    • 2020
  • A 45-year-old Korean male with laryngotracheal papilloma was treated using a 532-nm diode laser at six watts with a pulse width of 25 milliseconds. Two months after the laser treatment, the resected region was well-healed without significant scar contracture. This outcome suggests that a 532-nm diode laser can be a safe and effective treatment for laryngotracheal papilloma.

Evaluation of the effectiveness of diode laser therapy in conjunction with nonsurgical treatment of periimplantitis

  • Dicle Altindal;Eylem Ayhan Alkan;Metin Calisir
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.376-387
    • /
    • 2023
  • Purpose: Peri-implantitis (PI) is an inflammatory condition associated with the destruction of bone tissue around a dental implant, and diode lasers can be used to treat this disease. In this study, we aimed to evaluate the effectiveness of a 940-nm diode laser for the nonsurgical treatment of PI. Methods: Twenty patients (8 women and 12 men) were enrolled in a split-mouth randomized controlled study. In the control group (CG), mechanical debridement with titanium curettes accompanied by airflow was performed around the implants. The test group (TG) was treated similarly, but with the use of a diode laser. Clinical measurements (plaque index, gingival index [GI], probing pocket depth [PPD], bleeding on probing [BOP], clinical attachment level, and interleukin-1β [IL-1β] in the peri-implant crevicular fluid) were evaluated and recorded at baseline and 3 months. IL-1β levels were determined using the enzyme-linked immunosorbent assay method. Results: The symptoms were alleviated in both groups at 3 months as assessed through clinical measurements. GI, BOP, and PPD were significantly lower in the TG than in the CG (P<0.05). The IL-1β level increased post-treatment in both groups, but this increase was only statistically significant (P<0.05) in the CG. Conclusions: The diode laser enabled improvements in clinical parameters in the periimplant tissue. However, it did not reduce IL-1β levels after treatment. Further studies about the use of diode lasers in the treatment of PI will be necessary to evaluate the effects of diode lasers in PI treatment.

Design of General Audio Optical Pick-up Using Hologram Laser Diode (홀로그램 레이저 다이오드를 이용한 일반 오디오용 광학픽업 설계)

  • 최영석
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.1-8
    • /
    • 1998
  • In this paper, the optical pick-up used for general audio/video players having more market share than the others is designed with 4-wire suspension type actuator and the hologram laser diode which laser diode, photo diode, beam splitter, and grating lens are integrated in. This optical pick-up is designed in very simple optical system with the characteristics of hologram laser diode. Thus, it has high productivity, the number of the parts is reduced, and also the shape of the assembling parts becomes simple.

  • PDF

Simulation of Luminance and Uniformity of LGP According to the Laser Scattering Pattern (렌즈형 광섬유를 이용하여 펄스형 반도체 레이저 Beam Shaping 및 증폭 기술 연구)

  • Kwon, Oh-Jang;Kim, Ryun-Kyung;Shim, Young-Bo;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.6
    • /
    • pp.254-258
    • /
    • 2010
  • We investigate an optical technique for beam shaping and optical amplification of a pulsed laser diode without variation of its original properties, such as repetition rate and pulse duration. The horizontal and longitudinal sizes of the pulsed laser diode are 300 and $2{\mu}m$, respectively, and its output power is $1.1mW/cm^2$. The multimodal and elliptical pulse shape of the laser diode is converted to the single-modal and Gaussian pulse shape by using a lensed optical fiber. Since the single-modal lensed fiber coupling from the multimodal pulsed laser diode degrades the output power severely, the output power of the pulsed laser diode is dramatically enhanced by using an optical amplification method based on master oscillated power amplification (MOPA). The pulse qualities of the laser diode are not changed after amplifying the pulse power and the output power was finally measured to be $29mW/cm^2$.

Development of Laser Diode Medical Therapy Apparatus for Blood Stream Improvement (혈류 개선용 레이저다이오드 치료기 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.496-496
    • /
    • 2007
  • Low level laser therapy has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 7850m Laser diode for blood stream improvement and was designed for a pulse width modulation type to increase stimulation effects. In result, we could get the light power of 785nm wavelength.

  • PDF

Study of Chip On Glass Bonding Method using Diode Laser (다이오드 레이저를 이용한 Chip On Glass 접합에 관한 연구)

  • Seo M.H.;Ryu K.H.;Nam G.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.423-426
    • /
    • 2005
  • A new chip on glass(COG) technique by making use of a high power diode laser for LCD driver IC packaging of LCD has been developed. A laser joining technology of the connection of IC chip to glass panel has several advantages over conventional method such as hot plate joining: shorter process time, high reliability of joining, and better fur fine pitch joining. The reach time to cure temperature of ACF in laser joining is within 1 second. In this study, results show that the total process time of joining is reduced by halves than that of conventional method. The adhesion strength is mainly 100-250 N/cm. It is confirmed that the COG technology using high power diode laser joining can be applied to advanced LCDs with a fine pitch.

  • PDF