• 제목/요약/키워드: Dimensionless Number

검색결과 331건 처리시간 0.024초

FRONT PROPAGATION RATE OF DENSITY CURRENTS: DENSIMETRIC FROUDE NUMBER VERSUS DIMENSIONLESS FRONT VELOCITY

  • Choi, Sung-Uk
    • Water Engineering Research
    • /
    • 제3권1호
    • /
    • pp.9-22
    • /
    • 2002
  • In general, two dimensionless numbers are used in predicting the front propagation rate of density currents: the densimetric Froude number and the dimensionless front velocity. The former expresses the front speed in terms of the characteristic length and reduced gravitational acceleration. Previous papers report that the range of this dimensionless number is wide. The other is the dimensionless front velocity, which is a function of the buoyancy flux per unit width. This paper presents the state of the art review of the dimensionless numbers for the front propagation rate of density currents. Values of the densimetric Froude number are found to be consistent when the proper characteristic length is used for normalization. Then, the densimetric Froude number and the dimensionless front velocity are compared by using the experimental data of density currents over a horizontal surface.

  • PDF

보행 분석시 Dimensionless number의 효과 및 성별간 보행패턴 분석 -시공간변인- (Effect of dimensionless number and analysis of gait pattern by gender -spatiotemporal variables-)

  • 이현섭
    • 한국체육학회지인문사회과학편
    • /
    • 제53권5호
    • /
    • pp.521-531
    • /
    • 2014
  • 본 연구는 한국인 20대의 남성과 여성을 대상으로 보행 분석상의 표준화 방법 중의 하나인 dimensionless number의 효과를 검정하고 이를 통해 성별간 보행형태를 분석하는데 목적이 있다. 피험자는 기술표준원에서 제공하는 한국인 표준체형 및 연령 분류 체계에 맞춰 선정하였으며, 3차원 동작분석 시스템이 사용되었다. 데이터 분석을 위한 소프트웨어로는 Cortex, OrthoTrak, Matlab, Excel이 사용되었으며 통계검정을 위해서 SPSS를 사용하였다. 분석 결과를 살펴보면, Hof(1996)의 dimensionless number 변환을 통한 20대 성별 간 보행 형태는 시·공간 변인인 stride length, step length, stride time, step time, 보행속도(velocity), cadence 모두에서 유의한 차이가 없었으며, 표준화 전·후에 따라 통계분석의 결과가 달라짐을 확인하였다. 따라서 보행 분석에서 데이터의 표준화 방법 중의 하나인 dimensionless number의 적용은 통계학적 검정에 영향을 줄만큼 C.V. 값을 변화시키는 것으로 확인되었다. 본 연구를 통해, 상호 비교를 위한 보행연구에서 dimensionless number를 이용한 표준화 방식은 피험자의 신체적 특성이 분석에 미치는 영향을 제거하고 보다 정확한 통계 검정을 위해서 반드시 요구되는 과정이라는 것을 확인할 수 있었다.

2개의 수직휜이 부착된 내관으로부터 환상공간내의 자연대류 열전달 (Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins)

  • 정태현;정한식;권순석
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.654-660
    • /
    • 1991
  • Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins has been studied for the effects of dimensionless fin length and Rayleigh number. The maximum local Nusselt number of inner tube was obtained at .theta. = 145.deg. and that of outer cylinder at .theta. = 0.deg. for the case of $l_{F}$=0.3 Local Nusselt number distributions for the lower fins show higher values than that of the upper fins. The mean Nusselt number of inner tube was increased with the values of dimensionless fin length. The mean Nusselt number can be represented in an exponential function of Grashof number at various fin lengths. As compared with experimental and numerical results, isotherms and local Nusselt number show good agreement.t.

채널 유동에서 점성이 단일 입자 혼합 유동의 suspension에 미치는 영향 (Effect of Fluid Viscosity on the Suspension of a Single Particle in Channel Flow)

  • 최형권
    • 대한기계학회논문집B
    • /
    • 제33권3호
    • /
    • pp.194-200
    • /
    • 2009
  • Suspension of a single solid particle in a channel flow with a constant pressure gradient is studied numerically. The interaction of a circular particle with a surrounding Newtonian fluid is formulated using a combined formulation. Numerical results are presented using two dimensionless variables: the sedimentation Reynolds number and the generalized Froude number. From the present results, it has been shown that a solid particle is suspended at a smaller generalized Froude number as the viscosity of the surrounding fluid increases. The time taken for equilibrium position is found to be smaller as fluid viscosity increases when both : the sedimentation Reynolds number and the generalized Froude number are the same while, at the same situation, the dimensionless time taken for equilibrium position is to be nearly the same regardless of fluid viscosity when a dimensionless time variable is introduced

열교환기 형식에 따른 열교환기의 에너지 및 엔트랜시 성능 특성 해석 (Energy and Entransy Characteristic Analysis of Heat Exchangers Depending on Heat Exchanger Type)

  • 김경훈;정영관;한철호
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.112-121
    • /
    • 2020
  • In this work energy and entransy characteristics of heat exchangers are analyzed for 12 different flow arrangements of heat exchangers. The dimensionless parameters are number of entransy dissipation (Ng), number of entransy dissipation-based thermal resistance (Nr), and entransy dissipation-based effectiveness of heat-exchanger (εg). The dimensionless parameters are expressed analytically in terms of the effectiveness of heat exchanger (ε), heat capacity ratio (c), and number of transfer unit (N) for optimal performance of heat exchangers. Results showed that the dimensionless parameters based on the entransy dissipation can be useful concepts for optimal design of heat exchangers.

열교환기 핀에서의 서리층 물성치에 대한 실험 상관식 (Empirical Correlations of Frost Properties on the Fin of a Heat Exchanger)

  • 김경민;이관수
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.629-635
    • /
    • 2009
  • In this study, fin surface temperature and frost properties, i.e., frost thickness and frost surface temperature on a heat exchanger, were experimentally analyzed with different fin thicknesses, fin sizes and thermal conductivities of fin. As a result, it is found that fin thickness and thermal conductivity of fin should be considered in order to design an efficient heat exchanger fin. Correlations of dimensionless average frost properties were proposed as functions of dimensionless air temperature, dimensionless fin base temperature, dimensionless fin thickness, absolute air humidity, Reynolds number and Fourier number. The correlations predicted well the average frost thickness with a maximum error of 10.5% and frost surface temperature with a maximum difference of $0.89^{\circ}C$, respectively.

조건이 다른 수직 평형 평판에서 혼합대류 열전달 (Mixed Convection Heat Transfer from Two Vertical Parallel Plates with Different Conditions)

  • 김상영;정한식;권순석
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.243-252
    • /
    • 1992
  • A mixed convection heat transfer from two vertical parallel plates has been studied numerically by the finite difference method. Effects of the Grashof number, the relative length, $L_2/L_1$. the dimensionless temperature ratio, ${\Phi}_2/{\Phi}_1$ and the dimensionless plate spacing, $b/L_1$ are examined for the heat transfer. Independent of the Grashof numbers and $L_2/L_1$, the dimensionless vertical velocity distributions skewed on the left plate as ${\Phi}_2/{\Phi}_1$ decreased. The dimensionless vertical velocity distribution for $Gr/Re^2=1$ and ${\Phi}_2/{\Phi}_1=1.0$ is skewed to the right plate $L_2/L_1=0.5$, symmetric at $L_2/L_1=1.0$ and skewed to the left plate at $L_2/L_1=1.5$. But for $Gr/Re_2=10.0$ and ${\Phi}_2/{\Phi}_1=1.0$ reversed velocity patterns are obtained. Regardless of the Grashof numbers and $L_2/L_1$, the mean Nusselt nembers on the inside surface of the left plate decreases and those of the right inside surface increases as ${\Phi}_2/{\Phi}_1$ increases. Temperature, velocity and mean Nusselt number distributions are apparently not affected by $L_2/L_1$.

  • PDF

RADIATION EFFECTS ON MHD BOUNDARY LAYER FLOW OF LIQUID METAL OVER A POROUS STRETCHING SURFACE IN POROUS MEDIUM WITH HEAT GENERATION

  • Venkateswarlu, M.;Reddy, G. Venkata Ramana;Lakshmi, D. Venkata
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제19권1호
    • /
    • pp.83-102
    • /
    • 2015
  • The present paper analyses the radiation effects of mass transfer on steady nonlinear MHD boundary layer flow of a viscous incompressible fluid over a nonlinear porous stretching surface in a porous medium in presence of heat generation. The liquid metal is assumed to be gray, emitting, and absorbing but non-scattering medium. Governing nonlinear partial differential equations are transformed to nonlinear ordinary differential equations by utilizing suitable similarity transformation. The resulting nonlinear ordinary differential equations are solved numerically using Runge-Kutta fourth order method along with shooting technique. Comparison with previously published work is obtained and good agreement is found. The effects of various governing parameters on the liquid metal fluid dimensionless velocity, dimensionless temperature, dimensionless concentration, skin-friction coefficient, Nusselt number and Sherwood number are discussed with the aid of graphs.

비점성 정체 유동 응고 문제에 대한 이론적 해석 (A theoretical analysis on the inviscid stagnation-flow solidification problem)

  • 유주식
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.1-11
    • /
    • 2000
  • This study investigates the problem of phase change from liquid to solid in the inviscid stagnation flow. The solution of dimensionless governing equations is determined by the three dimensionless parameters of (temperature ratio/conductivity ratio), Stefan number, and diffusi-vity ratio. The solution at the initial stage of freezing is obtained by expanding it in powers of time, and the final equilibrium state is determined from the steady-state governing equations. The equilibrium state is dependent on (temperature ratio/conductivity ratio), but is independent of Stefan number and diffusivity ratio. The effect of fluid flow on the pure conduction problem can be clearly seen from the solution of the initial stage and the final equilibrium state, and the characteristics of the solidification process for all the dimensionless parameters are elucidated.

  • PDF

충돌제트를 이용한 pedestal 형상의 칩 냉각연구 (Jet Impingement Heat Transfer on a Pedestal Encountered in Chip Cooling)

  • 이대희;정승훈;정영석;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.124-130
    • /
    • 2001
  • The heat transfer and flow measurements were made on a cylindrical pedestal mounted on a flat plate with a turbulent impinging air jet. The heat transfer coefficient distributions on the flat plate were measured using the shroud-transient technique and liquid crystal was used to measure the surface temperature. The jet Reynolds number (Re) is 23,000, the dimensionless nozzle-to-surface distance (L/d) from 2 to 10, the dimensionless pedestal diameter-to-height (H/D) from 0 to 1.5, the dimensionless 2nd pedestal diameter-to-height ($H/D_2$) from 0 to 0.4 and the distance from the stagnation point to 2nd pedestal (p/D). The results show that for H/D = 0.5 to 1.5, the Nusselt number distributions on the plate surface exhibit a maximum between $r/d\;{\cong}\;1.0$ and 1.5. The presence of the pedestal appears to cause the flow separation and reattachment on the plate surface, which results in the maximum heal transfer coefficient. Also, for p/D = 2.5 and $H/D_2$ = 0.3, the local Nusselt number in the region corresponding to $r/d\;{\cong}\;1.1$ was increased up to 50% compared to that for $H/D_2=0$.

  • PDF