• Title/Summary/Keyword: Dilution ratio

Search Result 326, Processing Time 0.023 seconds

Fuel Dilution Effects for Stratified Premixed Flames (성층화된 예혼합화염에 대한 희석제 첨가의 영향)

  • Ahn, Taekook;Lee, Wonnam
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.73-76
    • /
    • 2013
  • The inert gas dilution effect for the stability of a stratified propane premixed flame has been experimentally studied. The addition of inert gases to a stratified premixed flame, which used to be very stable without dilution, makes a flame unstable. The lower equivalence ratio on the outer premixed flame and the lower fuel flow rate through the inner nozzle were observed to be the more stable conditions for the stratified premixed flame with nitrogen or argon dilution. It has been interpreted with the flame structure change such as shift of stoichiometric ratio region in a flame.

  • PDF

Preservation of Simmental bull sperm at 0℃ in Tris dilution: effect of dilution ratio and long-distance transport

  • Shouqing Jiang;Fei Huang;Peng Niu;Jieru Wang;Xiaoxia He;Chunmei Han;Qinghua Gao
    • Animal Bioscience
    • /
    • v.37 no.2
    • /
    • pp.203-209
    • /
    • 2024
  • Objective: This study aimed to assess the impact of the dilution ratio of Tris diluent, storage at 0℃, and long-distance transportation on the spermatozoa of Simmental cattle. It also validated the feasibility of the regional distribution of fresh semen. Methods: In experiment 1, semen was diluted at four dilution ratios (1:6, 1:9, 1:12, and 1:15) to determine the optimal dilution ratio of Tris diluent. In experiment 2, we assessed sperm viability, progressive motility (objectively assessed by computer-assisted sperm analyzer), and acrosome intactness in Tris dilutions kept at constant 0℃ for 1, 3, 6, 9, and 12 days. We compared them to Tianshan livestock dilutions (Commercial diluent). In experiment 3, semen was diluted using Tris diluent, and sperm quality was measured before and after long-distance transport. Artificial insemination of 177 Simmental heifers compared to 156 using Tianshan Livestock dilution. Results: The outcomes demonstrated that 1:9 was the ideal Tris diluent dilution ratio. The sperm viability, Progressive Motility, and acrosome integrity of both Tris and Tianshan dilutions preserved at 0℃ gradually decreased over time. sperm viability was above 50% for both dilutions on d 9, with a flat rate of decline. The decrease in acrosome integrity rate was faster for Tianshan livestock dilutions than for Tris dilutions when stored at 0℃ for 1 to 6 days. There was no significant difference (p>0.05) in sperm viability between semen preserved in Tris diluent after long-distance transportation and semen preserved in resting condition. The conception rates for Tris dilution and Tianshan livestock dilution were 49.15% and 46.15% respectively, with no significant difference (p>0.05). Conclusion: This shows that Tris diluent is a good long-term protectant. It has been observed that fresh semen can be successfully preserved for long-distance transport when stored under 0℃ conditions. Additionally, it is feasible to distribute semen regionally.

An experimental study on measurement of diesel particulate emission using dilution tunnels (희석터널을 사용한 디젤엔진 미립자상 배출물 측정에 관한 연구)

  • 채재우;김희수;오신규
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.40-48
    • /
    • 1987
  • A Mini-Dilution Tunnel is described as a scaled down comparision of a Standard Tunnel. The paper presents the result of experimental investigations on measuring the particulate emission of a diesel engine in a Mini and a Standard Dilution Tunnel. The result offers a contribution to understanding about the influence of several parameters including dilution ratios, mixture temperatures, mixture conditions, filter temperatures, and flow conditions. In the experiment either increasing the filter temperature and mixture temperature at a fixed dilution ratio or increasing the dilution ratio at a fixed filter temperature and mixture temperature resulted in a decrease in the total particulate mass. These changes in total particulate mass were attributed to the changes in the soluble organic fraction of the particulate sample. Also, mass differences between the Mini and the Standard Dilution Tunnel for the same engine conditions were within approximately 15% of each other.

  • PDF

Digital Dilution Chip Based on Use of Selective Inter-well Valve Control (다중 밸브를 이용한 디지털 희석 소자)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.535-539
    • /
    • 2010
  • We present a digital dilution chip comprising a $2{\times}6$ array of wells; the chip can be employed to change the dilution ratio as well as to initiate reactions among diluted samples by using the inter-well valve around the well. In previous dilution devices, streams comprising sample and dilution solutions were merged and separated by a branched microchannel. Therefore, the dilution ratio could not be changed until the structure of the branched microchannel was changed. The present device merges and splits the wells filled with sample or dilution solution by controlling inter-well valves around the wells. Thus, it is possible to change the dilution ratio by changing the sequence in which merging and splitting sequence of each well filled with sample or dilution solution. In experiments, we found that the chip could be used to change linear or exponential dilution ratios within an error of 16.7% and to initiate reactions among the samples within a reaction error of 17.7%.

Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack (화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증)

  • Shin, Dongho;Kim, Young-Hoon;Hong, Keejung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Lee, Ga-Young;Chun, Sung-Nam;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.15 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

A Study on the Sound Absorption Properties of Foamed Concrete According to Dilution Ratio of Foaming Agent (기포제 희석비율에 따른 기포콘크리트의 흡음특성에 관한 연구)

  • Kang Ki-Woong;Kang Chul;Kim Ha-Seok;Kwag Eun-Gu;Kwon Ki-Joo;Kim Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.5-8
    • /
    • 2005
  • Sound absorbing performance is affected by porosity and continuity of void, therefore it is important to maintain stabilization of foam and to analyze properties of void pore in hardened state. The purpose of this study is to analyze the sound absorption properties and void characteristic of foamed concrete according to dilution ratio of foaming agent. The results of this experiment were as follows. It is determined that an increase in total and continuous void ratio is achieved by increasing of dilution ratio, and a shorter absorbing time was exhibited at a higher continuous void ratio. When the average void size of foamed concrete was below 1.5mm, the tendency of sound absorption coefficient compared with general sound absorber was appeared similarly.

  • PDF

Characteristics of Thermo-Fluid Flow in Dilution Chamber of Micro-Dilution Tunnel for Diesel Particulate Measurement (디젤매연측정용 마이크로 희석터널의 희석챔버에서의 열유동 특성)

  • 김태권;김성훈;임문혁
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.90-99
    • /
    • 2002
  • The main purpose of this study lies on the development of micro dilution tunnel based on the Sierra Dilution chamber model. As a primary examination, characteristics of flow and temperature distributions during the steady dilution process in dilution chamber are observed with numerical analysis. The penetration of dilution air through porous tube as well as wall temperature and temperature gradient inside porous tube are examined. The thermophoretic velocity in terms of temperature behavior inside porous tube are defined and examined. Based on the ratio of penetration and thermophoretic velocities, all part of porous tube are shown to be safe from the particulate depositions. However, The inlet portion of porous tube in addition to the portion of impinging of dilution air are marginally safe from the particulate depositions. Generally the safer design against particulate deposition is required in provision f3r steady dilution process and for transient process as well.

Combustion Characteristics of Flameless Combustion by Reactants Injection Conditions (반응물 분사조건에 따른 무화염 연소특성 연구)

  • Hong, Seong Weon;Lee, Pil Hyong;Hwang, Sang Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.2
    • /
    • pp.8-16
    • /
    • 2013
  • The flameless combustion has been considered as one of the promising combustion technology for high thermal efficiency, reducing NOx and CO emissions. In this paper, the effect of air and fuel injection condition on formation of flameless combustion was analyzed using three dimensional numerical simulation. The results show that the high temperature region and the average temperature was decreased due to increase of recirculation ratio when air velocity is increased. The average temperature was also affected by entrainment length. Generally mixing effect was enhanced at low entrainment length and dilution was dominated at high entrainment length. This entrainment length was greatly affected by air and fuel injection velocity and distance between air and fuel. It is also found that the recirculation ratio and dilution effect were generally increased by entrainment length and the recirculation ratio, mixing and dilution effect are the significant factor for design of flameless combustion system.

Effects of Short-fiber End Shape on Tensile Properties of Reinforced Rubber (단섬유 끝 형상이 강화고무의 인장 특성에 미치는 영향)

  • Ryu, Sang-Ryeol;Lee, Dong-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.1023-1030
    • /
    • 2001
  • The tensile properties of short nylon6 fiber reinforced NR and SBR have been investigated as functions of diameter ratio(DR), interphase condition, fiber aspect ratio(AR), and fiber content. The short-fiber(DR=3 and AR=2) reinforced SBR did not show the dilution effect for all interphase conditions. And the short-fiber(DR=3 and AR=2) reinforced NR did not show the dilution effect except for the no-coating. The better interphase condition, the lower dilution effect at same DR. The tensile moduli are significantly improved due to fiber content and diameter ratio at same interphase condition. The pull-out force increased with the DR. The better interphase condition, the higher pull-out force at same DR. It is found that the DR and AR have an important effect on tensile properties.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.