• Title/Summary/Keyword: Dilution process

Search Result 252, Processing Time 0.026 seconds

Development of an Automated Measurement System for Dilution Process and Spraying Amount of Disinfectant

  • Kim, Jung-Chul;Chung, Sun-Ok;Cho, Byoung-Kwan;Chang, Hong-Hee;Kim, Suk;Chang, Dongil
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2013
  • Purpose: The objectives of this study were to develop an automated disinfectant dilution system, and an automated data management system for spraying amount for resolving uncertainty problem. Methods: Proper diluting rate was made by a controlled volume pump for liquid disinfectant and a screw conveyer pump for solid disinfectant. The water capacity of disinfecting system of 400 L was controlled by two water level sensors. The water quantity of water tank was controlled by the signals which were produced by the water level sensors. Signals were processed by Labview Programming, and ON/OFF of solenoid valve that was used for controlling water supplying to water tank, was controlled by SSR. The operating time of pumps for disinfectant was controlled quantitatively. A turbine flowmeter was used for development of automated measurement system for spraying amount of disinfectant. In order to save the flowmeter data and to control the spraying system, a multi-function data logger was used, and it was processed and saved in Excel file by a program developed in this study. Results: Labview 2010 was used for programming to control the automated measurement system for spraying amount of disinfectant. Results showed that the relationship between flowmeter value and time had a significant linear relationship such as 0.99 of $R^2$. Generally, 6.74 L/s of diluted disinfectant is sprayed for a vehicle passing through the disinfection system (about 15 seconds). Test results showed that average error between the measured spraying amount and the flowmeter data was 50 mL, and the range of error was 1.3%. Since the amount and time of spraying could be saved in real-time by using the spreadsheet files which could not be modified arbitrarily, it made possible to judge objectively whether the disinfection spraying was performed or not. Test results of spraying liquid and solid disinfectant showed that the errors between the measured discharge rate and the theoretical one were ranged within 3-4% for various dilution rates. Conclusions: The disinfection system developed would be working accurately. The automated spraying data base management system satisfied the purpose of this study. The automated dilution process system developed in this study could discharge liquid and solid disinfectant with accurate dilution rate, relatively.

A Study on Agricultural the Treatment of Organic Phosphorous Agricultural Pesticides Wastewater by the Activated Sludge Process (활성슬러지공정에 의한 유기인계 농약폐수처리)

  • 최택열;최규철
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.2
    • /
    • pp.36-41
    • /
    • 1995
  • In order to treat effectively various type of wastewater discharged from the manufacture factory of organic phosphorous agricultural pesticides by the activated sludge process. The acclimation test of sludge was carried out by the dilution of completely mixed raw wastewater. The results of experiment were obstained as follows. 1. The moderate dilution rate of mixed raw wastewater was founded to about 30 times. 2. The available range of BOD-SS loading was 0.1~0.15 $kg\cdot BOD/kg\cdot SS\cdot day$ and it was similar to the case of extended aeration activated sludge process. 3. After the acclimation of activated sludge, the concentration of MLSS was 2000 mg/L, removal efficiency of BOD more than 90%, and SVI 100, respectively. 4. The oxygen respiratory rate of acclimated sludge was $47 mg\cdot O_2/g\cdot hr$ and this was increased about 5 times than $10 mg\cdot O_2/g\cdot hr$ of ordinary sludge.

  • PDF

Radical Ring-Crossover Polymerization of Macrocycles with Radically Exchangeable Dynamic Covalent Bonds

  • Otsuka, Hideyuki;Yamaguchi, Go;Takahara, Atsushi
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.320-320
    • /
    • 2006
  • The authors report the synthesis and radical ring-crossover polymerization of macrocycles with radically exchangeable dynamic covalent bonds. The macrocyclic compounds with alkoxyamine units were designed and synthesized by condensation from alkoxyamine-based diol and the corresponding acid chlorides in the presence of pyridine under high-dilution condition. The macrocycles can thermally polymerize by intermolecular radical crossover reaction. Furthermore, the poly(alkoxyamine)s depolymerized to the monomers principally by the intramolecular radical exchange process under high-dilution conditions.

  • PDF

Studies on mixing of pharmaceutical powders

  • Choi, Woo-Sik
    • Archives of Pharmacal Research
    • /
    • v.5 no.2
    • /
    • pp.53-60
    • /
    • 1982
  • The mixing of salicylic acid and wheat starch powders was studied using a V-type mixer. After the optimum operating conditions of the mixer were examined, the mixing characteristics relating to dilution ratio, particle size of active ingradient and addition ratio of lubricants were investigated. The coefficient of variation was expressed by a power law relating to the dilution ratio and the particle size of active ingredient. Furthermore, the comparison of results with the theoretically estimated value of mixing index suggested that the mixing of cohesive pharmacceutical powders is a complex stochastic process and cannot be explained fully by a simple theory based on a complete random mixing.

  • PDF

The effect of dilution solvent ratio on dewaxing of waxy oils (Waxy Oil 탈납에 있어서 용제희석의 영향)

  • 김주항
    • Tribology and Lubricants
    • /
    • v.3 no.2
    • /
    • pp.34-43
    • /
    • 1987
  • The effect of dilution solvent ratio, and the mixing ratio of MEK and toluene on the solvent dewaxing process has been studied. The results of this study are Summarized as follows; 1. The best mixing ratio of solvent of MEK process and Toluene when in case of light and medium Waxy oils, which has low viscosity was 48: 52, and when in case of heavy waxy oil, which has high viscosity was 45: 55. 2. The best dilution solvent ratio when in case of low viscosity oils. was 1:2.8 against waxy oils after annexing 5 times divided as well as, when incase of high viscosity oil was 1:3.5 after annexing 2 times divided. 3. The chilling temperature was -26$\circ$C and the reguired dewaxing time depends on the viscosity of waxy oils.

Comparison of Powder Feeding and Wire Feeding in Laser Cladding (분말송급 및 와이어송급을 이용한 레이저 클래딩 특성)

  • Ahn, Young-Nam;Kim, Cheolhee
    • Journal of Welding and Joining
    • /
    • v.31 no.4
    • /
    • pp.13-16
    • /
    • 2013
  • In this research, laser cladding characteristics were investigated for various filler metal feeding methods such as powder, cold wire, and hot wire feeding. Appropriate parameter window, deposition rate, material efficiency and dilution for each filler feeding method were evaluated with same laser power and cladding speed range. Laser powder cladding has wider process parameter window but higher material efficiency and lower dilution were achieved by laser wire cladding. Among these feeding methods, laser hot-wire cladding showed best efficiency in material usage and deposition rate.

Nano-Soot Particle Formation in Ethene/Air Inverse Diffusion Flame (에틸렌/공기 역 확산화염에서의 나노 매연 입자 생성)

  • Lee, Eui-Ju;Shin, Hyun-Joon;Oh, Kwang-Chul;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1101-1109
    • /
    • 2004
  • Experimental measurements of flame structure and soot characteristics were performed fur ethene inverse diffusion flames (IDF). IDF has been considered as the excellent flow field to study the incipient soot because soot particle do not experience the oxidation process. In this study, LIF image clarified the reaction zone of IDF with OH signal and PAH distribution. laser light scattering technique also identified the being of soot particle. To address the degree of soot maturing, C/H ratio and morphology of soot sample were investigated. From these measurements, the effect of flow residence time and temperature on soot inception could be suggested, and more details on soot characteristic in the IDF was determined according to fuel dilution and flame condition. The fuel dilution results in a decrease of temperature and enhancement of residence time, but the critical dilution mole fraction is existed for temperature not to effect on soot growth. Also, the soot inception evolved on the specific temperature and its morphology are independent of the fuel dilution ratio of fuel.

Effect of White Water Quality on AKD Sizing of Linerboard (백수의 수질에 따른 라이너지의 AKD 사이징)

  • Lee, Hak-Lae;Seo, Man-Seok;Shin, Jong-Ho;Youn, Hye-Jung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.2 s.115
    • /
    • pp.9-15
    • /
    • 2006
  • Neutral sizing is required for linerboard to solve the troubles in strength and process caused by recycled raw materials. AKD sizing efficiency can be influenced by process condition like white water quality, fines retention and so on. Therefore, this study was aimed to evaluate sizing performance of general and fast cure type AKDs using process water obtained from linerboard mill. To evaluate effect of process water quality on AKD sizing, white water was diluted with tap water at the different dilution ratios and UKP slurry was sized using the prepared water. Also, effects of inorganic and organic ion material on sizing were examined. When white water was used for stock forming, UKP sheet showed very low sizing degree. Sizing degree of sheet was increased with increase of dilution ratio because water quality was improved. Especially anionic organic material had a greater influence on AKD sizing than inorganic material. When white water quality was deteriorated, fast cure type AKD showed superior sizing performance to general type AKD.

Production of Dye-decolorizing Enzyme using Molasses-containing Medium

  • Lee, Tae-Ho;Shoda, Makoto
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.57-58
    • /
    • 2000
  • Production of dye-decolorizing enzyme was investigated with the cultivation of Geotrichum candidum Dec1 (abbreviated to Dec1) using molasses as a cheap raw materials. Molasses was found to stimulate the enzyme production as well as a role of carbon source, because the production increased with molasses content up to 50 g/L. However, the severe inhibition of dye-decolorizing enzyme activity was observed even at low concentration of molasses 10 g/L when purified decolorizing peroxidase was used. Its inhibitory effect was reduced through the cultivation of Dec1. The fractions of molasses separated by a gel chromatography showed the different degrees of inhibition. As a way to reduce the inhibitory effect, the dilution of culture broth was examined, and the total decolorizing activity for Reactive blue 5 increased 7 times as much as that of original culture broth by 30 times dilution. On the basis of result, we proposed a process scheme which can fully utilize both positive and negative effect of molasses in dye-decolorizing process using molasses.

  • PDF

Review on the Process Safety of $SiH_{4}$ Gas used in Semiconductor and FPD Field (반도체 및 FPD 분야에 사용되는 $SiH_{4}$ 가스의 공정 안전 고찰)

  • Kim, Joung-Cho;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.32-36
    • /
    • 2007
  • When the vacuum system for the process of $SiH_{4}$ gas used in the semiconductor and FPD field is partially vented from vacuum to atmospheric state, a fire often occurs due to auto-ignition of $SiH_{4}$ gas. In order to prevent the fire, the concentration of $SiH_{4}$ should be kept under LFL. This means that the higher capacity pump is needed to meet the process conditions as well as the condition that the concentration of $SiH_{4}$ should be kept under LFL. In this article, we conducted the injection of the dilution gas at the manifold between booster pump and dry pump compared with the typical method that the dilution gas was injected into inlet port of booster pump using computer simulation. According to the result, we can flow further more purge gas for safety without any change of the condition in the process chamber, which means that the higher capacity pump is not required for safety in some cases.