• 제목/요약/키워드: Dilute Flow

검색결과 86건 처리시간 0.022초

이중 효용과 일중 효용을 복합한 다단 재생 고효율 흡수식 냉동 사이클 개발 (Development of High Efficiency Cycle by Combining Double-Effect with Single-Effect Absorption Chiller Systems)

  • 윤상국
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.360-365
    • /
    • 2017
  • Recently, development efforts of triple-effect absorption chiller have been increased in order to improve the efficiency of double-effect absorption chiller. However, triple-effect absorption chiller has some disadvantages, including high corrosion characteristic of LiBr solution at high temperature of $200^{\circ}C$. Moreover, it is necessary to develop new components for operation under high pressure of 2 bars even though COP is increased to 1.6 or 1.7. The objective of this study was to introduce a new system by combining double effect absorption chiller with single effect absorption chiller with multi-generators using bypass flow of LiBr dilute solution to $3^{rd}$ generator to overcome the disadvantages of triple-effect chiller and improve energy efficiency. Results indicate that the new absorption cycle had a much higher efficiency than double-effect chiller system, showing significant improvement when bypass solution flow rate of 25% was applied to the $3^{rd}$ generator using the main dilute solution of the absorber. The COP of the new chiller system was found to be 1.438, which was 21.7% higher than that (1.18) of the present double-effect system. The COP was decreased when solution by-pass rate to the $3^{rd}$ generator was increased. In addition, lower cooling water temperature caused higher COP. Therefore, the multi-generator system with by-pass solution might be an excellent chiller alternative to triple-effect absorption chiller with higher efficiency.

난류유동장에서 Shear - thinning 유체에 의한 마찰저항 감소에 관한 연구 (A Study on the Drag Reduction by Shear-thinning Fluid in Turbulent Flow Fields)

  • 차경옥;김재근;오율권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권2호
    • /
    • pp.126-135
    • /
    • 1997
  • Drag reduction in polymer solutions is the phenomenon where by extremely dilute solutions of high molecular weight polymers exhibit frictional resistance to flow much lower than the pure solvent. This effect, largely unexplained as yet, has attracted the attention of polymer scientists and fluid flow specialists. Although applications are beginning to appear, the principle interest to data has been in attempting to relate the effect to the fluid mechanics of turbulent flow. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, and pool and boiling flow. But the research on drag reduction in two phase flow is not intensively investigated. Therefore, experimental investigations have been carried out to analyze the drag reduction produced by polymer addition in the single phase and two phase flow system. The objectives of the proposed investigation are primarily in identifying and developing high performance polymer additives for fluid transportations with the benefits of turbulent drag. Also we want to is to evaluate the drag reduction in horizontal flow by measuring pressure drop and mean velocity. Experimental results show higher drag reduction using co - polymer(A611P) then using polyacrylamide (PAAM) and faster degradation using PAAM than using A611P under the same superficial velocity.

  • PDF

3개의 사이클론 갖는 순환유동층에서의 수력학적 특성 연구 (Hydrodynamic Study in the Cold CFB Reactor with 3-Cyclones)

  • 이종민;김재성;김종진
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.57-60
    • /
    • 1999
  • 순환유동층 보일러는 연소로 (상승관: riser)내에 공기를 고속으로 주입하여 비말동반되는 고체입자를 사이클론에서 포집 하여 재주입하는 유동층을 이르는 것으로, 난류유동층(turbulent fluidized bed), 고속유동층(fast fluidized bed) 그리고 희박상 유동(dilute phase flow) 영역에서 조업이 이루어진다. 순환유동층은 비교적 높은 기체 유속에서 조업이 이루어지기 때문에 고체입자의 혼합 및 비산 그리고 재순환이 격렬하게 이루어지고, 기-고체간 접촉효율 및 전열계수가 높아 전체적인 처리량 및 효율이 좋은 장점을 가지고 있다.(중략)

  • PDF

제트확산화염 소화농도의 비정상 유동효과 (Unsteady Flow Effects on Extinguishing Concentrations in Jet Diffusion Flames)

  • 지정훈;오창보;이의주
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.27-31
    • /
    • 2009
  • An experimental study on the unsteady effect of the extinction limit was performed in ethene jet diffusion flames. To impose the unsteadiness on jet flames, the amplitude and frequency of a co-flow velocity was varied, and the two inert gases, $N_2$ and $CO_2$, were used to dilute the oxidizer for extinguishing concentration. The experimental results shows that large amplitude of velocity induces a low extinguishing concentration, which implies that flow variation affects the blow out mechanism. Also, the flow oscillation effects under high frequency attenuates the flame extinction. These results means that flow unsteadiness extends the extinction limit and finally minimum extinction concentration by inert gases. When the Stoke's 2nd Problem is introduced to explain the flow unsteadiness on extinction concentration, the solution predicts the effect of amplitude and frequency of velocity well, and hence it is concluded the effect of low frequency velocity excitation was attributed only to flow effect.

알칼리 내성 Bacillus Sp.에 의한 생물 고분자의 희석용액 특성 (Dilute Solution Properties of Biopolymer Produced by Alkali-Tolerant Bacillus sp.)

  • 이신영;김진영
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.39-44
    • /
    • 2000
  • Highly viscous biopolymer from alkali-tolerant Bacillus sp. was purified and its solution properties were investigated. The intrinsic viscosities for crude biopolymer and biopolymers purified by dialysis or CPC(cetylpyridinium chloride) treatment were 58.24, 73.60 and 42.18 dL/g, respectively. The intrinsic viscosity of biopolymer showed the maximum value at the neutral pH but it was decreased remarkably at the alkaline or acidic pH. Biopolymer exhibited the property of polyelectrolyte, showing the sharp decrease of intrinsic viscosity by the addition of NaCl. Intrinsic viscosity of dilute solution at the low NaCl concentration was exponentially dependent on temperature and its temperature dependency was increased with NaCl concentrations. The chain stiffness, coil overlap parameter, and critical concentration were 0.09, 5.25 and 0.07g/dL, respectively. Temperature dependency on intrinsic viscosity of biopolymer solution was different each other at $45^{\circ}C$. Flow activation energies at temperatures above $45^{\circ}C$ were constant, while those at temperatures below $45^{\circ}C$ increased with increase of added NaCl concentration.

  • PDF

Rheological behavior of dilute bubble suspensions in polyol

  • Lim, Yun-Mee;Dongjin Seo;Youn, Jae-Ryoun
    • Korea-Australia Rheology Journal
    • /
    • 제16권1호
    • /
    • pp.47-54
    • /
    • 2004
  • Low Reynolds number, dilute, and surfactant-free bubble suspensions are prepared by mechanical mixing after introducing carbon dioxide bubbles into a Newtonian liquid, polyol. The apparent shear viscosity is measured with a wide-gap parallel plate rheometer by imposing a simple shear flow of capillary numbers(Ca) of the order of $10^{-2}$ ~ $10^{-1}$ and for various gas volume fractions ($\phi$). Effects of capillary numbers and gas volume fractions on the viscosity of polyol foam are investigated. At high capillary number, viscosity of the suspension increases as the gas volume fraction increases, while at low capillary number, the viscosity decreases as the gas volume fraction increases. An empirical constitutive equation that is similar to the Frankel and Acrivos equation is proposed by fitting experimental data. A numerical simulation for deformation of a single bubble suspended in a Newtonian fluid is conducted by using a newly developed two-dimensional numerical code using a finite volume method (FVM). Although the bubble is treated by a circular cylinder in the two dimensional analysis, numerical results are in good agreement with experimental results.

Experimental studies on the axisymmetric sphere-wall interaction in Newtonian and non-Newtonian fluids

  • Lee, Sang-Wang;Sohn, Sun-Mo;Ryu, Seung-Hee;Kim, Chongyoup;Song, Ki-Won
    • Korea-Australia Rheology Journal
    • /
    • 제13권3호
    • /
    • pp.141-148
    • /
    • 2001
  • In this research, experimental studies leave been performed on the hydrodynamic interaction between a spherical particle and a plane wall by measuring the force between the particle and wall. To approach the system as a resistance problem, a servo-driving system was set-up by assembling a microstepping motor, a ball screw and a linear motion guide for the particle motion. Glycerin and dilute solution of polyacrylamide in glycerin were used as Newtonian and non-Newtonian fluids, respectively. The polymer solution behaves like a Boger fluid when the concentration is 1,000 ppm or less. The experimental results were compared with the asymptotic solution of Stokes equation. The result shows that fluid inertia plays all important role in the particle-wall interaction in Newtonian fluid. This implies that the motion of two particles in suspension is not reversible even in Newtonian fluid. In non-Newtonian fluid, normal stress difference and viscoelasticity play important roles as expected. In the dilute solution weak shear thinning and the migration of polymer molecules in the inhomogeneous flow field also affect the physic of the problem.

  • PDF

금강호물의 새만금호 도입에 따른 금강호 수질변화 분석 (Estimation of Water Quality of Geumgang Lake by Diversion of Geumgang Lake Flow into Saemangeum Lake)

  • 엄명철;이재면
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1045-1051
    • /
    • 2006
  • Geumgang canal is planned to connect Geumgang lake with Saemangeum lake to accelerate desalinization and dilute polluted water to improve water quality in Saemangeum lake. The purpose of this study is to evaluate the impact of water quality on Geumgang lake by diversion of its lake flow to Saemangeum lake. WASP5 model was used to estimate water quality of Geumgang lake. Model calibration and verification were done for water quality data for 2001 and 2002. Water quality concentrations in Geumgang lake were simulated for 4 scenarios, which were considered whether the Geumgang canal is built or not. As a result of simulations, there was little impact on water quality in Geumgang lake, though a little of the Geumgang lake flow diverted to Saemangeum lake. As the Geumgang canal is planned to divert the Geumgang water flow which were discharged into the sea through sluice gates when canal is not built, it is thought that there will be little change by diversion of water flow.

저점성 SWNT 분산액 도포용 슬릿 노즐 설계를 위한 유동해석 (A STUDY ON FLOW IN A SLIT NOZZLE FOR DISPENSING A LOW-VISCOSITY SOLUTION OF SINGLE-WALLED CARBON NANOTUBES)

  • 손병철;곽호상;이상현
    • 한국전산유체공학회지
    • /
    • 제14권1호
    • /
    • pp.78-85
    • /
    • 2009
  • A combined theoretical and numerical study is conducted to design a slit nozzle for large-area liquid coating. The objectives are to guarantee the uniformity in the injected flow and to provide the capability of explicit control of flow rate. The woking fluid is a dilute aqueous solution containing single-walled carbon nanotubes and its low viscosity and the presence of dispersed materials pose technical hurdles. A theoretical analysis leads to a guideline for the geometric design of a slit nozzle. The CFD-based numerical experiment is employed as a verification tool. A new flow passage unit, connected to the nozzle chamber, is proposed to permit the control of flow rate by using the commodity pressurizer. The numerical results confirm the feasibility of this idea. The optimal geometry of internal structure of the nozzle has been searched for numerically and the related issues are discussed.

IN VIVO에서 고양이 상아세관을 통한 상아세관액의 흐름 (FLOW OF DENTINAL FLUID THROUGH CAT DENTINAL TUBULES IN VIVO)

  • 손호현;박수정;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.342-350
    • /
    • 1995
  • To determine the factors which affect the flow of dentinal fluid through cat dentinal tubules in vivo, the flow of fluid was measured by observing the movement of the fat droplets of dilute milk in a glass capillary with a microscope connected to the monitor. After measuring the exposed area of dentin, hydraulic conductances of dentin were calculated. The mean pressure which stoped the outward flow of dentinal fluid was 9.5mmHg. The hydraulic conductance of dentin under the condition of pulp exposed was increased by 21 % from that under the condition of dentin exposed. Under the conditions of pulp cut and pulp removed, the hydraulic conductances of dentin were increased by 22 % and 31 % respectively from that under the condition of dentin exposed. These results show that the direction and rate of dentinal fluid flow in cat dentin is affected mainly by the hydrostatic pressure of interstitial fluid of pulp tissue in the state of low compliance. Both of the osmotic effect produced by the protein constituents of interstitial fluid across the odontoblast tell layer and the change of interstitial fluid pressure produced by the state of the microcirculation of the pulp also affect the direction and rate of dentinal fluid in some degree.

  • PDF