• 제목/요약/키워드: Digitizer

검색결과 92건 처리시간 0.025초

기계자수 CAD시스템을 활용한 자수 텍스타일 디자인 전개 (The Development of Embroidery Textile Design Using Machine Embroidery CAD System)

  • 임정하;허승연
    • 한국의상디자인학회지
    • /
    • 제24권4호
    • /
    • pp.87-99
    • /
    • 2022
  • The purpose of this study is to develop machine embroidery textile designs for each technique that can be expressed using a single-headed computer embroidery sewing machine through a machine embroidery CAD system. For research, embroidery CAD utilized the Artistic digitizer, and the guillotine computer-mechanical magnetization machine used ELNA. The design concept was limited to portraits and relics of independence activists in six memorial halls built in Korea. The results of this study are as follows. First, it was found that the machine embroidery texture, which could only be produced by industries in the past, can be expand in the infinite creative embroidery design area by enabling the digitalization of motif images and the simulation of machine embroidery techniques through various layout options. Second, in the development of machine embroidery textures, it was found that the setting of the width, height, axis ratio, stitch, object, path, length, density, layer order, etc. in embroidery CAD is a very important part of determining the completeness of the embroidery results. Third, mechanical embroidery textile designs, which can be represented by single-head computer machine embroidery machine were able to show colorful embroidery results that differs from the original image by using seven main techniques and five deep technique alone or in combination, according to the designer's intention.

마우스와 터치스크린을 이용한 전자펜 에뮬레이터구현에 대한 연구 (A Study on Light Pen Emulator Implementation using Mouse and Touch Screen)

  • 조영석
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권9호
    • /
    • pp.39-44
    • /
    • 2014
  • 본 논문에서는 산업용 컴퓨터에서 사용할 마우스와 터치스크린을 이용한 전자펜 에뮬레이터 구현에 대하여 연구하였다. 산업용 제어 현장에서 사용되는 제어용 컴퓨터 전자펜 방식의 입력장치를 주로 사용하지만, 현재의 컴퓨터 주변장치를 직접 사용할 수 없는 경우가 대부분이다. 본 논문에서는 PC에서 사용하는 다양한 주변장치를 현재 구입 가능한 주변기기로서 그 기능을 대신하도록 구성하여, 생산 공정에서 사용하는 산업용 컴퓨터의 활용도를 높이고자 한다. 전자펜 에뮬레이터는 USB HOST, CPLD 그리고 MCU로 구성하였으며, USB 방식의 마우스와 터치스크린으로부터 입력된 신호를 해석한 후, 화면 좌표를 계산하여 전자펜 신호로 출력하였다. 설계 제작된 전자펜 에뮬레이터는 마우스, 디지타이져, 터치스크린 등 다양한 장치들을 산업용컴퓨터에서 사용이 가능함을 보였다.

비인두강(鼻咽頭腔)과 안면골격간(顔面骨格間)의 상관관계(相關關係)에 대(對)한 통계학적(統計學的) 연구(硏究) (A STATISTICAL STUDY ON THE CORRELATION BETWEEN THE NASOPHARYNGEAL SPACE AND THE DENTOFACIAL STRUCTURES)

  • 오성진;목하선지개
    • 대한치과교정학회지
    • /
    • 제17권2호
    • /
    • pp.255-277
    • /
    • 1987
  • 부정교합(不正交合)의 발생요인(發生要因)의 하나로서 비인두강(鼻咽頭腔)의 협착(狹窄)이 거론(擧論)되어 왔다 본(本) 연구(硏究)는 안면골격(顔面骨格)의 형태결정(形態決定)에 비인두강(鼻咽頭腔)의 기여정도(寄與程度)를 파악(把握)하고자 함에 있다 연구자료(硏究資料) 및 방법안(方法安) 한국인(韓國人) 성인(成人) 남녀(男女) 156 명(名)의 측모두부X선규격사진(側貌頭部X線規格寫眞)을 사용(使用)하여 NEC PC-9801 VM2 Personal Computer와 Oscon GT-4000 Digitizer에 의한 data 입력(入力)을 행(行)한 후 통계처리(統計處理)를 행(行)하였다 통계처리(統計處理)로서는 각계측치(各計測値)에 대하여 남녀별(男女別)로 평균치(平均値), 표준편차치(標準偏差値)를 산출(算出), Student's t-test를 행(行)하고, 비인두강(鼻咽頭腔) 계측항목(計測項目)과 안면골격(顔面骨格)의 각(各) 계측치간(計測値間)의 상관관계(相關關係)의 검토(檢討)를 행(行)하였다 결(結) 과(果) 1 남녀(男女)의 성차(性差)로서, 여자(女子)보다 남자(男子)가 상악골(上顎骨)에 대해 하악골(下顎骨)이 돌출(突出)되어 있었으며, 안면고(顔面高)가 컸다 2 Ba-S-PNS와 S-PNS-Ba간(間)에 부(負)의 상관(相關)이 인정(認定)되어, 이 두 계측치간(計測値間)애 상호작용(相互作用)이 있는 것으로 판단 되었다 3 비인두강(鼻咽頭腔)의 깊이는 하악(下顎)의 전후위치관계(前後位置關係)와 유의(留意)한 상관관계(相關關係)를 보였다 4 비인두강(鼻咽頭腔)의 깊이와 안면(顔面)의 깊이와는 관련성(關聯性)이 없는 것으로 판단 되었다 5 비인두강(鼻咽頭腔)의 깊이와 안면고간(顔面高間)에 유의(有意)한 부(負)의 상관(相關)이 시사(示唆)되었다 6 비인두강(鼻咽頭腔)의 고경(高經)과 안면고간(顔面高間)에 유의(有意)한 상관관계(相關關係)가 인정(認定)되었다.

  • PDF

한국인아동의 연조직측모의 성장변화에 관한 누년적 연구 (A LONGITUDINAL STUDY OF SOFT-TISSUE FACIAL PROFILE CHANGES IN KOREAN CHILDREN)

  • 정규림
    • 대한치과교정학회지
    • /
    • 제19권1호
    • /
    • pp.7-20
    • /
    • 1989
  • A serial cephalometric study was undertaken to define the growth of the soft tissue facial profile in Korean children. The sample was composed of 25 males and 15 females for whom yearly cephalometric records were taken from the ages of 6 to 13 years. From the tracings, points on skeletal and soft tissue profiles were located and recorded on magnetic tape utilizing a Calcomp Talos RP660 X-Y digitizer. Linear and angular measurements of soft tissues were made directly from tape in a Cyber 174-16 computer after cephalometric enlargement had been corrected. A statistical evaluation was made of the data and the average profile diagrams in male and female were described by a Calcomp 960 pen plotter. On the basis of the findings of this study, the following trends were established. 1. The most prominent growth in soft tissue facial profile thickness was the nose and the least was the forehead. 2. The general growth direction of the soft facial tissue to the cranium described the downward and forward. 3. The degree of soft tissue facial convexity was decidely more than that exhibited earlier in life even though the soft tissue chin had protruded to the cranium. 4. The measurements indicated a general tendency for males to have larger nose and more convex and long soft tissue facial profile than did females. 5. Males showed significantly more growth than females in base of the upper lip and height of the upper anterior facial profile. 6. There was a difference between males and females in the rates of soft tissue facial profile growth. 7. Korean children showed less convex in the soft tissue profile convexity than did American children.

  • PDF

새로운 저가형 고속 RF 자동화 테스트 시스템 (New Challenges for Low Cost and High Speed RF ATE System)

  • Song, Ki-Jae;Lee, Ki-Soo;Park, Jongsoo;Lee, Jong-Chul
    • 한국전자파학회논문지
    • /
    • 제15권8호
    • /
    • pp.744-751
    • /
    • 2004
  • 본 논문에서는 RF소자들의 테스트시 비용 절감을 극대화 할 수 있는 저가형 고속 RF 자동화 테스트 시스템(Automatic Test Equipment, ATE)의 제작에 관하여 다루어진다. 제작된 RF ATE는 고속의 스위칭 시간과 고정밀 디지타이저를 포함한 16개의 독립적인 RF 입출력 단자를 갖고 있으며 산업 표준인 VXI(Versus module eXtensions for Instrument)와 GPIB(General Purpose Interface Bus) 인터페이스를 사용하여 구성된다. 또한 소자의 생산효율을 극대화하기 위하여 동시에 4개의 소자를 테스트할 수 있도록 시스템이 구성된다. 마지막으로 현재 가격 경쟁이 상당히 심한 소자 중 하나인 RF 전력증폭모듈올, 제작된 RF ATE를 이용하여 테스트를 진행하여 시스템 성능을 검증한다.

공황장애와 복합부분간질 환자의 뇌자기공명촬영소견을 통한 불안의 해부학적 증거에 대한 연구 (A Study for Anatomical Evidence of Anxiety Using Magnetic Resonance Imaging in Patients with Panic Disorder and Complex Partial Seizure)

  • 최병휘;이영호;정영조
    • 생물정신의학
    • /
    • 제2권1호
    • /
    • pp.107-114
    • /
    • 1995
  • This study was to investigate the anatomical evidence of anxiety. MRI was used to study 11 patients with panic disorder and 15 patients with complex partial seizure, and 21 controls. The regions of interest in the MRI were measured with computer-assisted planimetry using the AutoCad and digitizer. The following results were obtained ; 1) The mean age was 49.7(12.4) years in patients with panic disorder and 30.1(7.5) years in patients with complex partial seizure. 2) There were na signi ficant differences between 3 groups in the values of cerebral area, temporal lobe, caudate nucleus, hippocampus, parahippocampus, amygdala, third ventricle and VBR. The right parahippocampal region which attracted most attention in neurobiological studies regarding anxiety, tended to be larger in both study groups compared to the control group, but with no statistical significance. 3) There was lett-right reversal of temporal lobes in both study groups. And these are mainly due to asymmetrical increase in area of the temporal lobe on right side. These results suggest that temporal lobe, especially right temporal, is the anatomical correspondence of anxiety and functional activation of temporo-limbic system may be accompanied by the structural change of temporal lobe.

  • PDF

Laser 방식 및 CCD 방식 Film Digitizer의 균일도 비교평가

  • 강원석;정해조;민덕기;김새롬;이상호;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.80-80
    • /
    • 2003
  • 디지털 의료영상 획득기술과 컴퓨터 및 네트워크 기술의 발달로 현재 각 병원에서는 PACS(Picture Archiving and Communication System)를 설치하여 필름을 사용하지 않고 진단과 진료를 하는 병원이 증가하고 있으며, 이에 따라 기존 필름상태의 의료영상은 필름디지타이저로 디지털 영상화한 후 모니터를 통하여 판독과 진료에 이용하고 있다. 본 연구에서는 현재 세브란스병원에서 사용되고 있는 CCD 방식 필름디지타이저와 레이저 스캐너방식 필름디지타이저의 픽셀값 균일도에 대해 중점적으로 비교, 분석하고자 한다. 픽셀값 균일도 측정을 위해 필름프린터를 이용하여 균일한 광학밀도를 가진 필름을 출력하였다. 그 테스트 필름은 각 사분면에 각기 다른 광학밀도를 가지고 있었으며, 그 광학밀도 값은 각각 0.19, 0.71, 1.41, 그리고 3.10 이었다. 제작된 필름은 레이저 (Model 2905, Array Corp., Japan) 방식과 CCD 방식 (SEDAS Media Film Scanner, Kodak, japan) 디지타이저에 의해 디지털화 되었다. 그 영상들은 다시 분석을 위해 PACS를 통해 PC로 전송되어졌고 자체 제작된 소프트웨어를 이용하여 균일도에 대한 분석을 수행하였다. 하나의 사분면 영상에 대하여 일정한 간격과 크기로 20개의 ROI를 만들고, 그 내부의 픽셀값들의 평균값을 구하여 그 영역의 대푯값으로 하였다. 그 대푯값들 중 최대값과 최소값의 차이에 대한 백분율로써 균일도를 표시하였다. 그 결과 광학밀도가 0.19인 사분변의 영상에서의 균일도는 레이저 방식 및 CCD 방식 각각에서 99.8%, 94.3%였으며, 0.71인 사분면에서는 99.4%, 75.6%, 1.41 일때는 97.9%, 62.96%, 그리고 3.1인 사분면에서는 82.7%, 53.7%였다. 같은 광학밀도를 가진 사분면에서는 레이저방식의 균일도가 CCD 방식에 비해 더 우수함을 알 수 있었으며, 같은 방식에서 얻은 영상이라 할지라도 광학 밀도값이 높은 사분변에서 얻은 영상일수록 균일도가 떨어짐을 알 수 있었다. 결론적으로, 레이저 방식 필름 디지타이저는 균일도 면에서도 CCD 방식에 비해 우수함을 알 수 있었으며 CCD 방식은 백라이트의 균일도가 영상의 균일도에 영향을 미칠수도 있는 만큼 향후 거기에 대한 연구도 이루어져야 할 것으로 생각된다.

  • PDF

후기발병 정신분열병 환자에서의 뇌자기공명촬영 소견에 관한 연구 : 조기발병 정신분열병, 진행성 정신분열병, 노인성 치매 및 대조군과의 비교 (Brain MRI Findings for the Patient with the Late Onset Schizophrenia : Comparison among Patients with the Early Onset Schizophrenia, Progressive Schizophrenia, Senile Dementia and Controls)

  • 박두성;이영호;최영희;박영수;정영조
    • 생물정신의학
    • /
    • 제4권1호
    • /
    • pp.74-83
    • /
    • 1997
  • With increasing tendency of incidence and interest for the late onset schzophrenia, concerns about whether this disorder is etiologically or phenomenogically distinctive entity or not have increased also. To clarify the disease entity of the late onset schzophrenia and the role of structural brain changes in its etiology, authors tried to prove following hypothesis : Are there any evidences of structural brain changes in the lateonset schizophrenia? ; If present, are they not different from those of the early-onset schizophrenia or progressive schizophrenia? ; And are they not different from those of senile dementia? Subjects were 6 patients with the late-onset schizophrenia, 6 patients with the early-onset schizophrenia, 6 patients with progressive schizophrenia, 6 patients with Alzheimer's dementia, and 6 controls. We measured regions of interest of the magnetic resonance images by computer assisted planimetry using the AutoCad and digitizer. Our study results may suggest that the third ventricular enlargement and a reversal of normal difference between left and right temporal lobe and left-right difference in posterior lateral ventricle are common brain pathology for all types of schizophrenia including the late onset schzophrenia. And also suggest that brain structural changes of the late onset schizophrenia are related with neurodevelopmental abnormality rather than degenerative change.

  • PDF

유한차분모형을 위한 직사각형 격자정보 생성기법 (Generation Method of the Rectangular Grid Information for Finite Difference Model)

  • 정신택;조범준;김정대
    • 한국해안해양공학회지
    • /
    • 제15권3호
    • /
    • pp.190-195
    • /
    • 2003
  • 연안 및 해안에서 발생하는 파랑변형, 조석 전파, 부유사 이동 및 확산 현상 등을 예측하기 위해서는 수치모형이 주로 사용된다 대표적인 수치모형 기법으로는 유한차분법 및 유한요소법이 있다. 유한차분법을 사용하는 경우에는 관심영역의 각 격자점에서 유한차분 방정식을 풀어야하므로, 격자망 및 경계조건 등이 설정되어야 한다. 유한차분용 격자망은 유한요소법과는 달리 격자망이 간단하지만, 지형이 복잡한 경우에 편리하게 사용 할 수 있는 격자정보 생성기법이 별로 개발되어 있지 않다. 또한, 상업용으로 많이 개발되어 있는 프로그램도 대부분 유한요소법에 근거한 수치모형에서 사용하는 격자생성을 목적으로 하고 있다. 본 연구에서는 디지타이저(Summagrid IV 기종)를 사용하여 유한차분모형을 위한 동일한 간격의 직사각형 격자 수심자료를 만드는 세부과정을 자료로 소개하고자 한다. 필요한 프로그램은 Golden Software사의 Didger(dititiger 지원 S/W)와 Surfer(gridding & contouring S/W)로서, 비교적 간단하게 정확한 수심 자료를 얻을 수 있으며, 임의의 지점 떠는 영역에 제시된 정보로부터 필요한 직사각형 격자정보를 추출하는 방법에 적용이 가능하다.

Normal Human Pleural Surface Area Calculated by Computed Tomography Image Data

  • Kim, Doo-Sang;Roh, Hyung-Woon
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권1호
    • /
    • pp.27-30
    • /
    • 2006
  • Background; Pleural micro-metastasis of lung cancer is detected by touch print cytology or pleural lavage cytology, but its prognostic impact has not elucidated yet. We hypothesize that recurrence may depend on the amount of tumor cells disseminated in pleural cavity, if the invasiveness of all cancer is the same. To predict the amount of tumor cells disseminated in pleural cavity, we need pleural surface area, distributed pattern of cells and concentration of cells per unit area. Human pleural surface area has not reported yet. In this report, we calculate the normal human pleural surface area using CT image data processing. Methods; Twenty persons were checked CT scan, and we obtained the data from each image. In order to calculate the pleural surface, the outline of lung was firstly extruded from CT image data using home-made Digitizer program. And the distance between CT images was calculated from the extruded outline. Finally a normal human pleural surface was calculated from function between the distance of consecutive CT images and the calculated length. Results; Their mean age is $65{\pm}12$ years old (range $26{\sim}77$), body weight is $62{\pm}9\;kg\;(48{\sim}80)$, and height is $167{\pm}6\;cm\;(156{\sim}176)$. The number of images used is $36{\pm}7\;(24{\sim}51)$. Pleural surface area is $211,888{\pm}35,756\;mm^2\;(143,880{\sim}279,576)$. Right-side pleural surface area is $107,932\;mm^2$ and Lt is $103,955\;mm^2$. Costal, mediastinal and diaphragmatic surfaces of right-side pleura are $77,483\;mm^2,\;39,057\;mm^2,\;and\;8,608\;mm^2$ respectively, and left-side are $72,497\;mm^2,\;35,578\;mm^2,\;and\;4,120\;mm^2$ respectively. Conclusion; Normal human pleural surface area is calculated using CT image data at first and the result is about $0.212\;m^2$.

  • PDF