• Title/Summary/Keyword: Digital-sensor device

Search Result 237, Processing Time 0.025 seconds

Changes in the quality of chest compressions applying a digital sensor device (디지털 센서 장비를 적용한 가슴 압박의 질 변화)

  • Yang, Hyun-Mo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.18 no.1
    • /
    • pp.107-116
    • /
    • 2014
  • Purpose : The purpose of this study is to demonstrate the effectiveness of using a digital sensor device during CPR by analyzing the results from that chest compressions with a digital sensor device are applied to cardiac arrest patients. Methods : This study analyzed the results from the experiment that 42 people were selected randomly among Korean 119 rescuers, and they divided into the experimental group using a digital sensor device and the control group only using their hands, then they had been observed to conduct chest-compressions to mannequins for 10 minutes. Results : The results were found that compression depth in both the control and experimental group was gradually decreased over time, but the experimental group not only kept the depth but also maintained the speed of chest-compressions close to 100 times a minute. In addition, due to the use of the digital sensor device, the insufficient recoil ratio of chest-compressions was significantly reduced. Conclusion : The results show that conducting chest-compressions with a digital sensor device keeps the compression-death, maintains the speed of chest-compression properly and makes the insufficient relaxation ratio of chest-compressions reduce significantly.

Development of a Digital Device for Measuring Soil Physical Properties (I) - Digital Shear Stress Sensor - (토양 물리성 측정을 위한 디지털 장치 개발(I) - 디지털 전단저항 측정장치 -)

  • Park, Jun-Gul;Lee, Kyou-Seung;Cho, Seung-Chan;Lee, Dong-Hoon;Chang, Young-Chang;Noh, Kwang-Mo
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.416-422
    • /
    • 2008
  • This study was performed to design and construct a digital soil shear stress sensor in order to replace the conventional devices for measuring soil shear property. The developed digital shear stress measuring device can store measured data with GPS position information as a vector format into a computer. Based on the experiments at various field conditions, the measuring characteristic of the device was quite similar to that of a conventional device, SR-2 that has been a major tool to measure the soil shear property. It was concluded that the digital shear stress measuring device was an effective and comprehensive sensor for measuring soil shear property.

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

Development of High-Precision Measuring Device for Six-axis Force/Moment Sensor (로봇용 6축 힘/모멘트 센서를 위한 고성능측정기 개발)

  • Shin, Hyi-Jun;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.46-53
    • /
    • 2007
  • This paper describes the development of a high-precision measuring device with DSP (digital signal processor) for the accurate measurement of the 6-axis force/moment sensor mounted to a humanoid robot's ankle. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, and Fz and moments Mx, My, and Mz to itself, and control the foot using the measured them. The applied forces and moments should be measured from two 6-axis force/moment sensors mounted to the feet, and the sensor is composed of Fx sensor, Fy sensor, Fz sensor, Mx sensor, My sensor and Mz sensor in a body (single block). In order to acquire output values from twelve sensors (two 6-axis force/moment sensor) accurately, the measuring device should get the function of high speed, and should be small in size. The commercialized measuring devices have the function of high speed, unfortunately, they are large in size and heavy in weight. In this paper, the high-precision measuring device for acquiring the output values from two 6-axis force/moment sensors was developed. It is composed of a DSP (150 MHz), a RAM (random access memory), amplifiers, capacities, resisters and so on. And the characteristic test was carried out.

Measurement of Surface Pressure Fluctuations on a Rotating Blade Using a Digital Recording Device (Digital Recording Device를 ol용한 회전중인 블레이드 표면의 압력섭동 측정)

  • Yun, Jung-Sik;Kang, Woong;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.10 s.241
    • /
    • pp.1119-1129
    • /
    • 2005
  • A new measurement system of wall pressure fluctuations on a rotating machinery, composed of digital recording device, was developed and evaluated. The small-sized digital recording device was attached on the rotating machinery and then was detached for data reduction. In order to obtain the system transfer function of the digital recording system, a dynamic calibration was performed utilizing the signal from a 1/8 inch B&K microphone as input. The time history of the unsteady pressure was then reconstructed from the output of the sensor by using this transfer function. The reconstructed pressure signals showed good agreement with the reference signal in both temporal and spectral sense. This sensor was then used to measure the wall pressure fluctuations on a rotating blade. An array of microphones were installed on the blade in the circumferential and radial directions. Various statistical moments were obtained from the measurement data set. Comparison of these quantities with the existing studies demonstrated satisfactory agreement. These tests give credence to the relevance and reliability of this device for applications in more complicated turbulent rotating machineries.

Development of a Contact-Type Counting Device Using a Piezoelectric Film as a Sensor (압전필름을 센서로 사용한 접촉식 계수장치 개발)

  • Yoo, Wan-Dong;Kim, Jin-Oh;Park, Kwang-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.239-247
    • /
    • 2005
  • This paper deals with the development of a contact-type counting device using a piezoelectric polymer film as a sensor. The piezoelectric and vibration characteristics of the film under a bending vibration were investigated theoretically and experimentally. A counting device, which includes filters, an amplifier, an analog-digital converter, and a display, was designed and fabricated. The performance of the piezoelectric polymer sensor was evaluated in the sense of the responses to contact force, contact frequency, and contact speed. The life and the temperature effect were also investigated for the piezoelectric film sensor.

Development of a Counting Device Using a Piezoelectric Sensor (압전 센서를 사용한 계수 장치 개발)

  • Yoo, Wan-Dong;Kim, Jin-Oh;Park, Kwang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1089-1092
    • /
    • 2004
  • This paper deals with the development of a contact-type counting device using a piezoelectric polymer film as a sensor. The piezoelectric and vibration characteristics of the film under a bending vibration were investigated theoretically and experimentally. A counting device, which includes filters, an amplifier, an analog-digital converter, and a display, was designed and fabricated. The performance of the piezoelectric polymer sensor was evaluated in the sense of the responses to contact force, contact frequency, and contact speed. The life and the temperature effect were also investigated for the piezoelectric film sensor.

  • PDF

Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won;Lee, Minho;Kang, Min Soo
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.154-160
    • /
    • 2019
  • In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

A Hybrid Adaptive Security Framework for IEEE 802.15.4-based Wireless Sensor Networks

  • Shon, Tae-Shik;Park, Yong-Suk
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.6
    • /
    • pp.597-611
    • /
    • 2009
  • With the advent of ubiquitous computing society, many advanced technologies have enabled wireless sensor networks which consist of small sensor nodes. However, the sensor nodes have limited computing resources such as small size memory, low battery life, short transmission range, and low computational capabilities. Thus, decreasing energy consumption is one of the most significant issues in wireless sensor networks. In addition, numerous applications for wireless sensor networks are recently spreading to various fields (health-care, surveillance, location tracking, unmanned monitoring, nuclear reactor control, crop harvesting control, u-city, building automation etc.). For many of them, supporting security functionalities is an indispensable feature. Especially in case wireless sensor networks should provide a sufficient variety of security functions, sensor nodes are required to have more powerful performance and more energy demanding features. In other words, simultaneously providing security features and saving energy faces a trade-off problem. This paper presents a novel energy-efficient security architecture in an IEEE 802.15.4-based wireless sensor network called the Hybrid Adaptive Security (HAS) framework in order to resolve the trade off issue between security and energy. Moreover, we present a performance analysis based on the experimental results and a real implementation model in order to verify the proposed approach.

Multi-scale wireless sensor node for health monitoring of civil infrastructure and mechanical systems

  • Taylor, Stuart G.;Farinholt, Kevin M.;Park, Gyuhae;Todd, Michael D.;Farrar, Charles R.
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.661-673
    • /
    • 2010
  • This paper presents recent developments in an extremely compact, wireless impedance sensor node (the WID3, $\underline{W}$ireless $\underline{I}$mpedance $\underline{D}$evice) for use in high-frequency impedance-based structural health monitoring (SHM), sensor diagnostics and validation, and low-frequency (< ~1 kHz) vibration data acquisition. The WID3 is equipped with an impedance chip that can resolve measurements up to 100 kHz, a frequency range ideal for many SHM applications. An integrated set of multiplexers allows the end user to monitor seven piezoelectric sensors from a single sensor node. The WID3 combines on-board processing using a microcontroller, data storage using flash memory, wireless communications capabilities, and a series of internal and external triggering options into a single package to realize a truly comprehensive, self-contained wireless active-sensor node for SHM applications. Furthermore, we recently extended the capability of this device by implementing low-frequency analog-to-digital and digital-to-analog converters so that the same device can measure structural vibration data. The compact sensor node collects relatively low-frequency acceleration measurements to estimate natural frequencies and operational deflection shapes, as well as relatively high-frequency impedance measurements to detect structural damage. Experimental results with application to SHM, sensor diagnostics and low-frequency vibration data acquisition are presented.