• Title/Summary/Keyword: Digital valve

Search Result 100, Processing Time 0.026 seconds

Nonlinear analysis of a pneumatic actuation system by digital simulation (전산모사에 의한 공압구동장치의 비선형 해석)

  • 조택동;신효필;문의준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1104-1109
    • /
    • 1991
  • Recently, Pneumatic Actuation System (PAS) has been used increasingly as a high performance fin-control servo actuation systems because of the special advantages of pneumatic units: primarily their low cost, small size, light weight, and tolerance to broad temperature extremes. In this study, a nonlinear model of PAS is derived through the detailed analysis of the major components in the typical system. The model includes nonlinear flow-pressure relationships of the flow through the solenoid valve openings and orifices, PWM algorithm for driving two solenoid valves as a closed-center 3-way valve for minimum gas consumption, solenoid valve dynamics, saturation, and friction. Simulation results are compared with the experimental ones for square and sinusoidal inputs to see the validity of the model. Independent of the shape and magnitude of the input signals, both results are in good agreements with minor difference.

  • PDF

Development of automatic flow control system based on LabView (LabView를 이용한 자동유량제어 시스템의 개발)

  • Kang, Tae-Won;Kim, Du-Seob;Ann, Sung-Gyu
    • Journal of Engineering Education Research
    • /
    • v.19 no.2
    • /
    • pp.3-7
    • /
    • 2016
  • A flow control system was designed and fabricated to control the flow rate of liquid through the pipe. This control system was composed of hardwares and software, hardwares as controller, gate valve, orifice meter and data aquisition board and software as National instruments Labview program. Control of flow rate was executed by adjusting the pneumatic valve located at the center of pipe line based on the control signal generated by LabView PID control algorithm, which converts analog signal measured by pressure difference of orifice to digital signal to adjust pneumatic valve. For the controller setup Ziegler-Nichols tuning technique was applied and control performances were investigated for not only the disturbance but also the set point changes. Developed system showed good control performances in flow control enough to use as teaching tool of feedback control theory and practice in university, and also as industrial application.

Controller for Gas Leakage Protection in Semiconductor Process Chamber (반도체 제조장비용 챔버 가스누출 방지를 위한 제어모듈 개발)

  • Park Sung-Jin;Lee Eui-Yong;Sul Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.5
    • /
    • pp.373-377
    • /
    • 2005
  • In this paper the gas leakage controller in processing chamber for semiconductor manufacturing is proposed. A pressure sensor is connected between the final valve and the numeric valve. A pressure sensor signal and a numeric valve signal are controlled by a proposed digital circuit module. Gas leakage condition, producing by 2nd plasticity in semiconductor process, display at LED. The proposed controller module is useful for monitoring the gas flow for preventing the critical process gas leakage.

  • PDF

Braking Pressure Characteristics of Solenoid-Flow Control Type ABS by PWM Control (PWM 제어에 의한 솔레노이드-유량제어방식 ABS의 제동압력 특성)

  • Song, Chang-Seop;Yang, Hae-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.8
    • /
    • pp.146-154
    • /
    • 1997
  • Solenoid-folw control type ABS is used with a 'dump and reapply' pressure control arrangement instead of using 2/2 (normal open/close) solenoid valves in convensional systems(sol. -sol. control type), a flow control valve is used which replaces the (no) inlet valve. The flow control valve controls fluid flow providing a nearly constant reapply rate( .theta. ) after the dump plase of ABS operation. In this study, to investigate a characteristics of brake pressure by PWM control, test rig was consisted of ABS hydraulic modulator, digital controller, pneumatic power supply and brake master cylinder. For comparison with experi- mental results, system modelling and computer simulation were performed. As a result, experiment results showed fairly agreement with the simulation. Also, it is shown that the pressure gradient (tan .theta. ) is affected by pressure, frequency, duty ratio and expressed with an exponential funtion.

  • PDF

Development of Bi-directional Triple-eccentric Type Butterfly Valve (양방향 삼중편심 버터플라이 밸브 개발)

  • Kim, Soo-Young;Lee, Dong-Myung;Bae, Jung-Hoon;Shin, Sung-Chul;Sul, Chang-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.5
    • /
    • pp.545-551
    • /
    • 2009
  • In naval architecture and offshore engineering, the development and a broad use has been achieved in the field of flow control valves for pipe system. Butterfly valves are also widely used for flow control, but there are not many studies for triple-eccentric butterfly valves. Moreover, if the fluid of pipeline flows in the bi-direction then it makes more complicate to adapt triple-eccentric butterfly valves to flow control. In this study, we are trying to develop a bi-directional triple-eccentric butterfly valve through sealing mechanism and stem design study. Digital mockup using 3D CAD was constructed for shape interference check and structural analysis was conducted for structural safety. Also we performed leakage test to check out the durability of the bi-directional pressure for the developed valve.

A Study on the Fluid Leakage Evaluation for Power Plant Valve Using Acoustic Imaging Technique (음향 영상화기법을 이용한 발전용 밸브 유체누설평가 연구)

  • Lee, S G.;Lee, S.K.;Kim, D.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • Image processing has provided powerful techniques to extract from the acoustic signals the desired information on evaluation for leakage existence, leakage rate, and searching for leakage location, etc. The imagery NDE data available can add additional and significant dimension in nondestructive evaluation(NDE) information and thus for exploiting in applications. To extract such information the use of advanced image processing techniques is much needed. In recent years, there has been much increased use of acoustic signal image processing techniques in acoustic NDE. This approach will increase the efficiency of inspection procedures and reduce inspection time. In this paper we are concerned only with This paper is concerned mainly with the use of advanced image processing techniques in valve leakage detection and advanced image restoration and enhancement methods, which attempt to evaluate promptly by a visualization method the acoustic sources while detecting the valve leakage.

A Study on Load Control in a Steam Turbine Power Plant using Acquired Data (운전데이터에 의한 증기터빈 발전소의 부하제어에 관한 고찰)

  • Woo, Joo-Hee;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.749-751
    • /
    • 1999
  • We acquired operating data in an existing steam turbine power plant using analog control system to investigate operation characteristics. We analyzed a load control logic to develop a digital turbine control system. The load control logic is constituted of load target, load reference, loading rate, load limit and admission mode transfer of valve. The result of this paper is utilized to implement a digital turbine control system.

  • PDF

Nonlinear digital simulation for the analysis of a hydraulic servo system (비선형 디지탈 시뮬레이션에 의한 유압서보 시스템 해석)

  • 이상열;문의준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.346-351
    • /
    • 1987
  • In this study, digital simulation with nonlinear modeling is carried out to analyse the performance of a hydraulic servomotor system developed for the position control of a large inertia. Nonlinear element, such as nonlinear pressure flow relationships of servovalve, valve spool limits, nonlinear friction, and backlash and resilience of gear system are included in the simulation along with the dynamic characteristics of variable delivery pump compensation mechanism. Simulation results are compared with experimental results for both step and sinusoidal inputs. Independent of input magnitude, both results are in good agreement with minor differences in detail.

  • PDF

Realization of one chip for opto-couplers in driving circuit of electric valve (전동밸브의 구동회로에서 Opto-Coupler들의 one chip화 구현)

  • 정원채
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.181-184
    • /
    • 2001
  • This paper has been studied driving circuits in electrical valves. Also in this paper, opto-couplers of driving circuit are replaced with digital one chip of Altera company. Designs in order to realization of one chip are carried out with Altera Max Plus II. For compact size and light weight, the realization with one chip is necessary in the electrical valves. This paper has designed and presented the digital schemetic circuits, finally the driving circuits are sucessfully operated with the designed chip and showed the saving of area in the driving circuits of electric valves.

  • PDF

Flow Characteristics in the Downstream Region of a Butterfly Valve with Various Disk Opening Angle (디스크 회전각에 따른 버터플라이 밸브 하류에서의 유동특성)

  • Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.267-272
    • /
    • 2006
  • Butterfly valves have been used for shut-off and throttling-control application in many industrial fields. Recently, they are frequently used for cooling water, oil system and ballast piping system of many larger vessels. They are especially suited for flow throttling control of heat exchangers in engine room. Measurement by the PIV(Particle Image Velocimetry) was conducted to investigate the flow characteristics of butterfly valve inserted within circular pipe. Flow behaviors such as instantaneous and time-mean velocity vectors are investigated. Furthermore, to reveal systematic performance of the butterfly valve, wall pressure was measured at 6 points along the pipe by digital manometer. As the valve position moves to the closed side, flow separation increases and persists its tendency downstream until smoothly uniform flow developed. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 60 degrees.

  • PDF