• 제목/요약/키워드: Digital torque gauge

검색결과 35건 처리시간 0.029초

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants

  • Mohammed, Hnd Hadi;Lee, Jin-Han;Bae, Ji-Myung;Cho, Hye-Won
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.62-69
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION. Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.

풀림토크를 이용한 임플란트 토크조절기의 비교 (Comparison of Implant Torque Controllers using Detorque Value)

  • 허윤혁;조리라;김대곤;박찬진
    • 구강회복응용과학지
    • /
    • 제26권4호
    • /
    • pp.419-432
    • /
    • 2010
  • 현재 임상적으로 여러 형태의 토크 조절기가 사용되고 있고, 토크 조절기에 따라 오차율이 다양하게 보고되고 있는데 제조회사에서 권장하는 적절한 조임력으로 나사가 조여지지 않을 경우 나사 풀림과 이에 따른 파절이 발생하여 결과적으로 보철물과 임플란트 매식체에 합병증이 야기될 수 있으므로 토크 조절기의 정확성이 필수적이다. 본 연구에서는 일정 토크 수준이 넘으면 핸들의 앞 부위가 꺾여지도록 만들어진 토크 최대값 제한 장치(TLD, torque limiting device), 눈금자가 표시되어 있는 활 형태로 조임력의 크기를 조절할 수 있는 토크 표시 장치(TID, torque indicating device), 콘트라앵글 핸드피스 형태에 조임력의 크기를 조절하거나 이미 정해진 조절기를 끼워서 사용하는 콘트라앵글 토크 조절장치(CA, contraangle torque device), 기계적인 토크 발생장치를 이용하여 적정 회전력을 가하는 전자 토크 조절기(ETC, electronic torque controller)등 네 종류의 토크 조절기를 이용하여 제조회사의 지시대로 나사를 조인 후 풀림 토크값을 측정하고 각각의 차이값을 구하여 토크 조절기의 정확도를 비교, 분석하고자 하였다. 콘트라앵글 토크 조절장치(CA)가 가장 측정값에 근접한 결과를 보였으며 토크 최대값 제한 장치(TLD)를 제외한 나머지 세 종류의 토크 조절기의 정확도는 서로 통계적으로 유의한 차이를 보이지 않지만, 토크 최대값 제한 장치(TLD) 의 경우 유의하게 낮은 정밀성을 보였으므로 이는 토크 부여 시 회전 속도에 따른 오차발생 가능성을 보여준다. 토크 표시 장치 (TID), 콘트라앵글 토크 조절장치 (CA) 와 같은 수동 토크 조절기는는 전자식 토크 조절기와 오차 범위 내에서의 유사한 정밀성을 보여주고 있으며 이는 임상에서 보다 주의 깊게 장치를 사용한다면 효과적인 전하중 부여가 가능함을 의미한다.

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구 (Accuracy of spring-style and friction-style mechanical implant torque wrench)

  • 차동희;오상천
    • 대한치과보철학회지
    • /
    • 제54권1호
    • /
    • pp.8-13
    • /
    • 2016
  • 목적: 본 연구의 목적은 두 가지(스프링형, 마찰형) 종류의 기계식 임플란트 토크 렌치를 2000회의 반복 사용과 100회의 멸균과정 후 그들의 정확도를 평가하는 것이다. 재료 및 방법: 각기 다른 5개 제조사의 스프링형, 마찰형 기계식 임플란트 토크 렌치가 각 15개씩, 총 30개 사용되었다. 디지털 토크 측정기(MGT-12, Mark-10 Corp, USA)를 이용하여 토크값을 실험 전 최초 측정 후 각 토크 렌치를 같은 조건(목표 토크 값까지 20회씩 반복 사용 후 멸균봉투에 포장하여 고압증기 멸균 시행)으로 100회 반복 시행하였다. 그 후 다시 토크값을 측정하여 비교하였다. 수집된 자료는 SPSS 통계분석 프로그램을 이용하여 분석하였고 오차율을 계산하였다. Mann-Whitney-U test를 이용하여 실험군 사이의 유의성을 분석하였다(P<.05). 결과: 스프링형 토크 렌치는 실험 전후로 토크값의 유의할만한 차이를 보이지 않았다(P>.05). 반면에 마찰형 토크 렌치는 실험 전후로 토크값의 유의할만한 차이를 나타내었으며(P<.05), 10% 이상의 오차율이 모두 마찰형 토크 렌치에서 나타났다. 결론: 본 연구의 제한된 실험 조건하에서 스프링형 토크 렌치가 마찰형 토크 렌치보다 사용횟수와 멸균과정을 고려했을 때 더욱 신뢰성이 높은 정확도를 보였다.

나사 접근 구멍 각도가 조절 가능한 새로운 경사형 지대주의 파절강도 및 나사 풀림력 연구 (Evaluation of Fracture Strength and Screw Loosening of a New Angled Abutment with Angulated Screw Channel)

  • 최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.623-628
    • /
    • 2023
  • The purpose of this study was to evaluate the fracture strength and removal torque value (RTV) of a conventional angled abutment and a newly developed angled abutment (Beauty up abutment) with an angulated screw access hole. Each abutment was divided into a control group and an experimental group (n = 20, respectively). To measure the fracture strength, the abutment was connected to the internal hex implant with 30 Ncm torque, and a load was applied at 30 degree angle with cross-head speed of 1 mm/min using a universal testing machine according to the ISO 14801:2016 standard. To measure RTV, each abutment was fastened to the implant with 30 Ncm torque. Retightening was performed after 10 minutes, and initial RTV was measured with a digital torque gauge. After retightening, a load of 250 N was applied to the abutment at a 30 degree angle using a chewing simulator. After a total of 100,000 repeated loads, RTV was measured. Statistical analysis was performed using Wilcoxon signed rank test and Mann-Whitney U test (α = .05). The fracture strength of the experimental group was statistically significantly lower than that of the control group (P = .009). There was no significant difference between initial RTV and post-loading RTV between the experimental group and the control group (P = .753, P = .527, respectively), and cyclic loading did not significantly affect RTV in both groups (P = .078).

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

골유착전 임플란트 고정체의 의원성 동요가 골결합에 미치는 영향 (The influence of intentional mobilization of implant fixtures before osseointegration)

  • 조진현;조광헌;조성암;이규복;이청희
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.149-155
    • /
    • 2012
  • 연구 목적: 이 논문은 임플란트 고정체가 골융합이 이루어지기전 의원성 동요가 있을 경우 골결합에 어떤 영향을 미치는지를 알아 보고자 한다. 연구 재료 및 방법: 실험에 사용한 임플란트는 직경 3.73 mm, 길이 4 mm의 순수한 타이타늄과 RBM ($MegaGen^{(R)}$: Ca-P) 처리된 임플란트(Grade IV)를 사용하였다. 몸무게 3.5kg 이상의 토끼(Female, New Zealand White)의 한쪽 경골에 2개씩 양쪽 다리에 임플란트를 식립하여 모두 80개의 임플란트가 식립되었다. 비틀림 제거력(Removal torque)의간격에 따라 그룹 I (6주), 그룹 II (4일+6주), 그룹 III (4일+1주+6주), 그룹 IV (1주+6주), 그룹 V (1주+1주+6주), 그룹 VI (2주+6주), 그룹 VII (2주+1주+6주), 그룹 VIII (3주+6주), 그룹 IX (3주+1주+6주), 그룹 X (10주)으로 10개의 그룹으로 나누었다. 본 실험에서 그룹 I과 그룹X가 대조군이며, 비틀림 제거력은 digital torque gauze (Mark-10, USA)를 사용하여 6주와 10주에 측정하였다. 실험군에서는 마지막 비틀림 제거력을 측정하기 전에 의원성 동요를 가하여 한 번 혹은 두 번 비틀림 제거력을 측정하여 그 수치를 기록하였다. 그 후, 대조군을 제외하고 비틀림 제거력을 측정한 임플란트는 가급적 원래의 위치로 돌려 놓고 봉합을 하였다. 모든 실험군은 마지막 비틀림 제거력 측정전까지 6주간의 치유기간을 주었으며, 마지막 비틀림 제거력은 실험군 첫 번째 또는 두 번째 비틀림 제거력값과 비교하여 결과를 분석하였다. 결과: 마지막 비틀림 제거력 측정값에서 그룹X (10주)의 값이 대조군인 그룹 I (6주)의 값보다 높았으나, 통계적으로는 유의하지 않았다. 실험군과 대조군 사이의 통계적으로 유의한 차이를 보이지 않았다(P>.05). 첫 번째 비틀림 제거력 측정치에서, 실험군(4일혹은1주)에서 다른 실험군(2주혹은3주)의 수치보다 낮은 값을 보였다. 치유기간에 따른 각 실험군의 비교에서, 최종 비틀림 제거력 값이 첫 번째 비틀림 제거력 값 보다 현저히 높은 값을 보였다. 결론: 골유착이 형성되기 전 한 번 또는 두 번 의원성으로 동요는, 만약 충분한 치유기간을 가지게 될 경우 임플란트의 골유착에 영향을 주지 않는다.

임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향 (AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING)

  • 이태식;한중석;양재호;이재봉;김성훈
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).