Comparative Evaluation of North American Symptomatic Carotid Endarterectomy Trial and Warfarin-Aspirin Symptomatic Intracranial Disease Methods for Measurement of Middle Cerebral Artery Stenosis in Digital Subtraction Angiography and Magnetic Resonance Angiography (디지털 감산 혈관조영술과 자기 공명 혈관조영술에서 중대뇌동맥의 협착 측정을 위한 North American Symptomatic Carotid Endarterectomy Trial 및 Warfarin-Aspirin Symptomatic Intracranial Disease 방법의 비교 평가)

  • Lee, Jung-Hoon;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.351-356
    • /
    • 2019
  • This study aimed to determine whether there was a difference in measurements between North American Symptomatic Carotid Endarterectomy Trial(NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease(WASID) methods that measure the middle cerebral artery stenosis in Digital Subtraction Angiography (DSA) and Magnetic Resonance Angiography (MRA). It involved 24 patients who had completed both DSA and MRA among patients with Middle Cerebral Artery (MCA) stenosis. The Middle Cerebral Artery (MCA) stenosis was measured using the NASCET and WASID methods through a retrospective analysis. For the NASCET and WASID methods, they performed measurements on normal blood vessels located far from and close to the stenosis, respectively. The mean value and standard deviation of the Digital Subtraction Angiography (DSA) measured by the NASCET method were 59.23% and 13.27%. On the other hand, those of the Digital Subtraction Angiography (DSA) measured by the WASID method were 66.64% and 12.47%. And, the mean value and standard deviation of the Magnetic Resonance Angiography (MRA) measured by the NASCET method were 49.82% and 12.06%. By contrast, those of the Magnetic Resonance Angiography (MRA) measured by the WASID method were 56.63% and 10.67%. All the p-values obtained by the Pearson and Spearman correlation tests in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) were <0.01. In conclusion, this study suggests that both the NASCET and WASID methods to measure the middle cerebral artery stenosis in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) can be used if they are not used interchangeably.

QUANTITATIVE ANALYSIS OF THE ALVEOLAR BONE CHANGE BY THE DIGITAL SUBTRACTION RADIOGRAPHY (Digital subtraction radiography를 이용한 치조골 변화의 정략적 분석)

  • Ryue, Myung-Girl;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.67-75
    • /
    • 1995
  • The progress of periodontal disease and the wound healing process after treatment result in alveolar bone bone change. So, detection of it is very important in the diagnosis and the radiograph of periodontal disease. Various effects have been made to assess the subtle alveolar bone change and digital subtraction radiography (DSR) has been reported to be the best method in evaluating it qualitatively and quantitatively. The present study was performed to estimate the detectable alveolar bone change qualitatively with digital subtraction radiography. For the in vitro study, 10 intraoral standard radiographs were taken from porcine dry mandible which a rectangular cortical bone chip of 0.1mm to 1.0mm thickness with 0.1mm increment was attached on the buccal surface. The radiographs without and with bone plates were reviewed at the same time by 10 observers and requested to detect the presence of cortical bone plates. Digital Subtraction radiograph was reviewed subsequently by using the DSR system(digital converter-256 grey-levels,DT 2851,Data Translation Co., U.S.A;IBM 386 ; CCD camera, FOTOVIX, Tamrom Co., Japan). The detectable thickness of cortical bone plate was O.4mm on the intraoral radiograph and 0.2mm on the subtaction images. For the human study, radiographs were taken from patients by using intraoral film holding device and aluminum reference wedge before and 3 month after bone graft and 1 week after osteoplasty. The grey level change was estimated in the subtraction images and calculated to aluminum equivalent thickness. The grey level of the grafted site was higher that that of healthy controls. Average grey levels of change on healthy controls were O.48mm aluminum equivalent. However, the amount of changes in grafted sites were 1.87mm aluminum thickness equivalent and in the site of osteoplasty were -1.49mm aluminum thickness equivalent. In conclusion, digital subtraction radiography was more effective in detecting as subtle change of alveolar bone than intraoral standard radiography. With the aid of quantitative analysis of digital subtraction radiography, alveolar bone resorption of apposition can be estimated during diagnosis and treatment of periodontally diseased patients.

  • PDF

A comparison of subtracted images from dental subtraction programs (디지털공제프로그램간의 디지털공제영상 비교)

  • Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

A Study on Non-Subtraction and Subtraction Technique in 3-Dimensional Angiography of the Cerebral Aneurysm (뇌동맥자루 3차원 혈관조영술에서 비감산 및 감산 기법에 관한 연구)

  • Kim, Kyung-Wan;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.511-518
    • /
    • 2018
  • The purpose of this study was to measured the diameter, maximum diameter, maximum area and volume of the cerebral aneurysm in 53 patients who underwent three-dimensional digital angiography and three-dimensional digital subtraction angiography, which were used for the clinical diagnosis of cerebral aneurysm, image noise and radiation exposure dose of each test method were analyzed to compare clinical diagnosis differences in the cerebral aneurysm diagnosis. Three-dimensional digital angiography and three-dimensional digital subtraction angiography showed that the neck diameter, maximum diameter, maximum area, volume, and noise of the cerebral aneurysm were identical or very small. However, the three-dimensional digital angiography significantly decreased the radiation exposure dose compared to three-dimensional digital subtraction angiography. Therefore, in case of clinical diagnosis of cerebral aneurysm, three-dimensional digital angiography should be preferentially used to reduce radiation exposure dose of patient.

Bone loss Detection in Dental Digital X-ray Image by Structure Analysis (구조적 분석을 이용한 치과용 디지털 X-ray 영상에서의 골조직 변화 검출에 관한 연구)

  • Ahn, Yong-Hak;Chae, Ok-Sam
    • The KIPS Transactions:PartB
    • /
    • v.11B no.3
    • /
    • pp.275-280
    • /
    • 2004
  • In this paper, we propose automatic subtraction radiography algorithms to overcome conventional subtraction radiography's defects by applying image processing technique. In order to reach these goals, this paper suggests the image alignment method that is necessary for getting subtraction image and ROI(Region Of Interest) focused on a selection method using the structure characteristics in target images. Therefore, we use these methods because they give accurary, consistency and objective information or data to results. According to the results, easily and visually we can identify fine difference int the affected parts wether they have problems or not.

Digital Subtraction Technique for Intravenous X-ray Image System (컴퓨터 영상처리 방식을 이용한 정맥내 혈관 조영술 시스템 개발)

  • 이승지;이태수
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.109-116
    • /
    • 1981
  • The objective of this research is to develop the hardware and software systenls of the digital intravenous angiographic system. The system will be used in clinical diagnosis of cardiovascular and cerebrovascular diseases. By utilizing computer image processing technique and digital subtraction method, the system can decrease the patient's harzard and expenses in performing intravenous angiography, as compared with conventional angiograms of the arterial injection.

  • PDF

Flexible Background-Texture Analysis for Coronary Artery Extraction Based on Digital Subtraction Angiography (유동적인 배경 텍스쳐 분석을 통한 DSA 기반의 관상동맥 검출)

  • Park Sung-Ho;Lee Joong-Jae;Lee Geun-Soo;Kim Gye-Young
    • The KIPS Transactions:PartB
    • /
    • v.12B no.5 s.101
    • /
    • pp.543-552
    • /
    • 2005
  • This paper proposes the extraction of coronary arteries based on DSA(Digital Subtraction Angiography) through a texture analysis of background in the angiography. DSA is a well established modality for the visualization of coronary arteries. DSA involves the subtraction of a mask image - an image of the heart before injection of contrast medium - from live image. However, this technique is sensitive to the movement of background and can result to a wrong detection by the variance of background gray-level intensity between two images. Therefore, this paper solves a structural problem resulted from a background movement bV selecting an image which has the least difference of movement through an analysis of the similarity of background texture and proposes a method to extract only the blood vessel efficiently through local gray-level correction of the selected image. Using the coronary angiogram of 5 patients clinical data, we proved that the proposed method has the lower false-detection rate, approximately $2\%$, and the higher accuracy than the existing methods.

Automatic Registration of Images for Digital Subtraction Radiography Using Local Correlation (국소적 상관계수를 이용한 자동적 디지털 방사선 영상정합)

  • 이원진;허민석;이삼선;최순철;이재성
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.111-117
    • /
    • 2004
  • Most of digital subtraction methods in dental radiography are based on registration using manual landmarks. We have developed an automatic registration method without using the manual selection of landmarks. By restricting a geometrical matching of images to a region of interest (ROl), we compare the cross-correlation coefficient only between the ROIs. The affine or perspective transform parameters satisfying maximum of cross-correlation between the local regions are searched iteratively by a fast searching strategy. The parameters are searched on the 1/4 scale image coarsely and then, the fine registration is performed on the original scale image. The developed method can match the images corrupted by Gaussian noise with the same accuracy for the images without any transform simulation. The registration accuracy of the perspective method shows a 17% improvement over the manual method. The application of the developed method to radiography of dental implants provides an automatic noise robust registration with high accuracy in almost real time.

Moving Object Surveillance System based on Image Subtraction Technique (영상 Subtraction을 이용한 이동 물체 감시 시스템)

  • 이승현;류충상
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.60-66
    • /
    • 1997
  • In this paper, a moving object surveillance system, which can extract moving object in real-time, using image subtraction method is described. This technique based on the novelty filter having the structure of neural network associative memory. Digital arithmetic and timing control parts were composed of hardwired controller to treat two-dimensional massive image information. SRAMS having 20 ns access time were used for the image buffer that has high speed write/read property. Image extraction algorithm is discussed and supported by simulation and experiments.

  • PDF

Proximal caries detection using digital subtraction radiography in the artificial caries activity model (인공 치아우식 발생 모델에서 디지털 방사선 공제술을 이용한 인접면 치아우식증의 진단)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Young-Ho;Kim, Kyung-Sook;Jin, Hyun-Seok;Hong, Kyung-Won;Oh, Berm-Seok;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Materials and Methods: Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. Results: In artificial caries activity model, the range of lesional depth was $572-1,374{\mu}m$ and the range of lesional area was $36.95-138.52mm^2$. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. Conclusion: The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  • PDF