• Title/Summary/Keyword: Digital scan

Search Result 376, Processing Time 0.021 seconds

Research and Development of High Performance 42-inch XGA Plasma Display Panel

  • Choi, Kwang-Yeol;Min, Byoung-Kuk;Kim, Tae-Hyung;Song, Byung-Soo;Yoo, Eun-Ho;Kim, Jin-Young;Jung, Yun-Kwon;Kim, Won-Tae;Yang, Hee-Chan;Ryu, Jae-Hwa
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.231-235
    • /
    • 2004
  • High performance 42 inch XGA PDP with high luminance of 1,000 cd/$m^2$ has been developed using high efficient electrode structure, discharge gas and closed barrier ribs. For high speed addressing with single scan technique, address discharge time lag was reduced over 40% with FAST driving scheme and new materials. High dark room contrast ratio of 5,000 : 1 was achieved and picture quality was improved using new algorithm for eliminating false contour and improving gray level linearity.

  • PDF

Application of interactive comic frame-manner for digital comics (인터랙티브 만화연출을 적용한 디지털 코믹스 연구)

  • Kim, Chee-Hoon;Hur, Young
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.652-656
    • /
    • 2007
  • It devides that a comic book is based on paper and the other one is serviced through the medium of internet. Each one called conventional form of comic book and digital one; however, it is simply uploaded scan-images of comic book on monitors instead of paper. This is just only difference of output form of comics and it does not bring out digital feature. Thus the new possibility of digital comics will be searched with the core of digital contents, interactivity is applied for comic frame-manner.

  • PDF

Use of Intraoral Scanners for Fabricating Fixed Restoration: Clinical Tips (구강 스캐너를 사용한 고정성 보철 수복 시 고려사항)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.524-528
    • /
    • 2019
  • With the advances of CAD-CAM (computer-aided design and computer-aided manufacturing) technology, the field of modern clinical dentistry has been dramatically changed. The first step in the digital workflow for tooth-supported dental prosthesis is a data acquisition with intraoral digital or conventional impression techniques. For the accuracy of intraoral digital impression data, the basic principles of conventional impression should be applied. It is necessary to obtain a good visibility with properly-dried field and well-exposed margin of the prepared abutment. Currently, the equi- or supra-gingival finish line can be recommended as an indication for intraoral digital impression. The scan data are generally exported to '.stl' file format, which has only morphological information of black and whitem while '.obj' file format can store data on color and texture.

  • PDF

Accuracy of interocclusal record established by different occlusal scans (교합스캔의 이용 방식에 따른 교합면간기록의 정확성)

  • Minjee Kang;Cheong-Hee Lee;Kyu-Bok Lee;So-Yeun Kim;Du-Hyeong Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.142-148
    • /
    • 2024
  • Purpose: The purpose of this study was to investigate the accuracy of digital mounting with occlusal scans in the interocclusal record for a full-mouth fixed prosthetic treatment condition. Materials and Methods: The entire maxillary teeth were prepared in a dentiform model and attached to an articulator in maximum intercuspation. Temporary crowns were fabricated and occlusion was adjusted. After scanning the arch with tooth preparation, digital mounting was performed using an occlusion scan of the anterior or posterior teeth areas. The accuracy of the positioned jaw relation was evaluated three-dimensionally through positional deviation and angular error of the occlusal plane. Afterwards, the same procedure was repeated on the partially edentulous model to evaluate the accuracy of digital interocclusal record. Kruskal-Wallis test and Mann-Whitney U test were used for statistical analysis, and the significance level was set at 0.05. Results: There was no significant difference in the positional error at the center of the arch in the digitally established jaw relation depending on the scan area used and remaining tooth conditions (P = 0.53). The angular error of the occlusal plane was larger when the anterior teeth were used as the overlapping area, and a smaller error value was observed when both posterior teeth were used as the overlapping area (P < 0.001). Conclusion: The use of bilateral posterior occlusal scans is recommended when digitally mounting the jaw relation established with temporary teeth during full-mouth fixed prosthetic treatment.

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

3-step digital complete denture restoration using facialscan: a case report (안면 스캔을 이용한 3회 내원 디지털 총의치 수복: 증례보고)

  • Yeongseok Kwon;Seoung-Jin Hong;Janghyun Paek;Ahran Pae;Hyeong-Seob Kim;Kung-Rock Kwon;Kwantae Noh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.356-366
    • /
    • 2023
  • Support, retention, and stability of dentures are key factors in the use of complete dentures in edentulous patients. With the development of digital dentistry, attempts are being made to replace traditional treatment methods. Also, struggle to reduce the number of patient visits and to manufacture high-quality digitally fabricated dentures are ongoing. In this case, a digital denture was restored using a tray capable of obtaining centric relation through gothic arch tracing and a facial scan. By replacing the traditional complete denture restoration method, the number of patient visits was reduced and esthetic results with satisfactory denture support, retention, and stability were obtained.

SAR Payload Technology for Next Generation Satellite (차세대 위성용 SAR 탑재체 기술)

  • Won, Young-Jin;Yoon, Jae-Cheol;Kim, Jin-Hee
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.131-141
    • /
    • 2014
  • Synthetic Aperture Radar (SAR) is a powerful and well established microwave remote sensing technique which enables high resolution measurements of the Earth surface independent of weather conditions and sunlight illumination. In this study, this paper first summarizes the basic SAR theory and the history of the SAR satellites. The second part of this paper gives an overview of new technologies for future SAR systems. New innovative concepts and technologies for SAR satellites will be digital beamforming, High Resolution Wide Swath (HRWS), Waveform Encoding, Terrain Observation by Progressive Scan (TOPS), and so on. These technologies will play an important role for future spaceborne SAR satellites.

Development of Digital 3D Real Object Duplication System and Process Technology (디지털 3차원 실물복제기 시스템 및 공정기술 개발)

  • Lee Won-Hee;Ahn Young-Jin;Jang Min-Ho;Choi Kyung-Hyun;Kim Dong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.4 s.181
    • /
    • pp.183-190
    • /
    • 2006
  • Digital 3D Real Object Duplication System (RODS) consists of 3D Scanner and Solid Freeform Fabrication System (SFFS). It is a device to make three-dimensional objects directly from the drawing or the scanning data. In this research, we developed an office type SFFS based on Three Dimensional Printing Process and an industrial SFFS using Dual Laser. An office type SFFS applied sliding mode control with sliding perturbation observer (SMCSPO) algorithm for control of this system. And we measured process variables about droplet diameter measurement and powder bed formation etc. through experiments. In case of industrial type SFFS, in order to develop more elaborate and speedy system for large objects than existing SLS process, this study applies a new Selective Dual-Laser Sintering (SDLS) process and 3-axis Dynamic Focusing Scanner for scanning large area instead of the existing f lens. In this process, the temperature has a great influence on sintering of the polymer. Also the laser parameters are considered like that laser beam power, scan speed, and scan spacing. Now, this study is in progress to evaluate the effect of experimental parameters on the sintering process.

Experimentation on The Recognition of Arithmetic Expressions (수식 표현의 인식에 관한 연구)

  • Lee, Young Kyo;Kim, Young Po
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.29-35
    • /
    • 2014
  • The formula contains up between the text and the structural information, as well as their mathematical symbols. Research on-line or off-line recognition formula is underway actively used in various fields, and various forms of the equation are implemented recognition system. Although many documents are included in the various formulas, it is not easy to enter a formula into the computer. Recognition of the expression is divided into two processes of symbol recognition and structural analysis. After analyzing the location information of each character is specified to recognize the effective area after each symbol, and to the structure analysis based on the proximity between the characters is recognized as an independent single formula. Furthermore, analyzing the relationship between the front and back each time a combination of the position relationship between each symbol, and then to add the symbol which was able to easily update the structure of the entire formula. In this paper, by using a scanner to scan the book formula was used to interpret the meaning of the recognized symbol has a relative size and location information of the expression symbol. An algorithm to remove the formulas for calculation of the number of formula is present at the same time is proposed. Using the proposed algorithms to scan the books in the formula in order to evaluate the performance verification as 100% separation and showed the recognition rate equation.