Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

디지털 의료영상에서 Flat-Field 보정에 따른 Noise Power Spectrum 분석 (Analysis of Noise Power Spectrum According to Flat-Field Correction in Digital Radiography)

  • 이미나;권순무;천권수
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.227-232
    • /
    • 2013
  • 엑스선 디지털 검출기의 내부 픽셀들은 조금씩 다른 감도와 오프셋 변동을 가지게 되어 불균일한 영상이 얻어진다. 이러한 문제를 해결하기 위해서 flat-field 보정 방법이 개발되었고, 이는 디지털 의료 영상 시스템의 전처리 과정에서 필수적으로 수행된다. 그럼에도 불구하고 여러 가지 이유로 균일하지 않은 영상이 획득되는 경우가 종종 발생한다. 본 연구에서는 디지털 의료 영상 장비에서 획득된 불균일한 영상에 flat-field 보정을 다시 적용시켜 화질이 개선되는 것을 확인하였다. 그리고 객관적인 화질의 평가를 위해 보정 전후의 NPS를 각각 산출하여 비교하였다. 주파수 영역에서 잡음의 변화를 분석한 결과 저주파수 성분의 잡음이 flat-field 보정 후에 크게 제거된 것을 확인할 수 있었다.

Digital 방사선 영상의 질 관리 표준화에 관한 연구 (Quality of management of Digital Radiography Study on the standardization)

  • 임청환;정성훈
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2016년도 춘계 종합학술대회 논문집
    • /
    • pp.141-142
    • /
    • 2016
  • 의료 기관에서 정확한 진단하기 위해 아날로그 시스템인 Film System보다 Digital System을 선호하고, 장비의 설치 또한 Digital System으로 많이 보급이 되고 있다. 장비가 많이 보급이 되었지만 현재 장비에 대한 안전관리나 품질관리는 미흡하다고 할 수 있다.이에 본 연구는 Digital System의 품질관리의 중요성을 알리고, 품질관리의 항목을 설정하여, 기준 값을 제시하고자 3개월 동안 SNR, MTF, DQE를 측정한 결과 다음과 같이 나타났다. 1달은 SNR 4.02, MTF 50% 4.6lp/mm, DQE는1.4로 측정이 되었다. 3주후 SNR은 3.55, MTF 50% 3.0lp/mm, DQE는 0.7로 나타났다. 3개월 뒤 SNR은 3.45, MTF 50% 2.1lp/mm, DQE는 0.5로 나타났다. 시간이 지나갈수록 영상의 디지털영상의 물리적 평가들이 저하되는 것으로 나타났다. 시간이 지나감에 따라 의료영상이 저하됨에 따라 안전관리 뿐만 아니라 영상의 품질관리도 같이 이루어져야 할 것이다.

  • PDF

흉부 X-Ray 영상개선을 위한 신경망 적용에 관한 연구 (A Study to Apply the Neural Networks for Improvement of X-Ray Chest Image)

  • 이주원;이한욱;이종회;신태민;김영일;이건기
    • 전자공학회논문지SC
    • /
    • 제37권1호
    • /
    • pp.49-55
    • /
    • 2000
  • 흉부의 병변을 진단하기 위해 주로 사용되고 있는 흉부 X-선 촬영은 최근 컴퓨터 기술의 발달에 힘입어 디지털화 되고 있다. 디지털화된 흉부 영상을 방사선과 전문의가 모니터 상에서 관찰할 때 흉부 영상의 품질이 고르지 못하여 병변을 검출하기가 어려울 뿐만 아니라 이로 인하여 많은 진단 시간이 소요된다. 따라서 본 연구에서는 디지털 흉부 영상을 개선하기 위해 신경망을 이용하여 흉부 X-선 영상의 등화 방법을 제안하고 그 결과를 히스토그램 등화 방법과 비교하여 제시하였다.

  • PDF

관심영역을 이용한 치과용 방사선 영상에서의 자연치아 주위 미세변화 검출에 관한 연구 (Periondontal Disease Detection in Dental Radiography by ROI segment)

  • 안용학;이정헌;채옥삼
    • 대한전자공학회논문지SP
    • /
    • 제41권6호
    • /
    • pp.73-80
    • /
    • 2004
  • 본 연구에서는 자연치아 주위 골조직의 미세 변화를 검출하는 의료영상처리 기술에 대한 방안을 제안한다. 제안된 방법은 먼저, 입력되는 두장의 디지털 방사선 영상에서 자연치아의 형태 분석을 통하여 자연치아의 외곽선 및 직선선분을 검출하고, 검출된 외곽선 및 직선선분을 이용하여 예상되는 환부영역(관심영역)을 분리한다. 분리된 환부영역을 중심으로 에지기반 정합을 통한 영상정렬을 수행함으로써 기존의 관심영역이외의 영역에서 오류 정보가 표시되는 문제점을 해결하고, 또한 기존의 수동적인 방법을 통한 결과의 객관성 및 정확성에 대한 문제를 해결하였다. 실험 결과, 신속하고 정확하게 자연치아 주위의 미세 변화에 대한 검출이 가능하였고, 보다 객관적이고 정량적인 결과를 제시할 수 있음을 보여주었다.

미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석 (Correlation Analysis of Control Factors in Automatic Exposure Control of Digital Radiography System Based on Fine Contrast Images)

  • 임세훈;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study was to analyze the effect of automatic exposure control (AEC) control factors in digital radiography systems based on the fine contrast images using coin phantoms. The AEC control factors were targeted at the range of dominent zone, sensitivity, and density. The dominent zone was divided into cases where a single coin was used to cover the field configuration, and cases where seven coins were used to cover the field configuration. The sensitivity was classified into three stages (200, 400, 800) and the density was classified into three stages (2.5, 0, 2.5). Image quality was evaluated by signal to noise ratio (SNR) and contrast to noise ratio (CNR). Then, the automatically exposed tube current was measured. As a result, the X-ray image of seven coins obtained a result value of about 1.2 times higher for SNR and 1.9 times higher for CNR than the X-ray image for one coin. The tube current was also about 1.6 times higher. In conclusion, In AEC, the higher the field configuration and dominent zone are matched and the higher the density, the lower the sensitivity, which increases the tube current and CNR, which increases the image quality. Therefore, it is judged that the appropriate setting of the range of dominent zone, sensitivity, and density of the control, which is the AEC control factor, could improve the fine contrast of images.

Automatic Anatomically Adaptive Image Enhancement in Digital Chest Radiography

  • Kim, Sung-Hyun;Lee, Hyoung-Koo;Ho, Dong-Su;Kim, Do-Il;Choe, Bo-Young;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.442-445
    • /
    • 2002
  • We present an algorithm for automatic anatomically adaptive image enhancement of digital chest radiographs. Chest images were exposed using digital radiography system with a 0.143 mm pixel pitch, l4-bit gray levels, and 3121 ${\times}$ 3121 matrix size. A chest radiograph was automatically divided into two classes (lung field and mediastinum) by using a maximum likelihood method. Each pixel in an image was processed using fuzzy domain transformation and enhancement of both the dynamic range and local gray level variations. The lung fields were enhanced appropriately to visualize effectively vascular tissue, the bronchus, and lung tissue, etc as well as pneumothorax and other lung diseases at the same time with the desired mediastinum enhancement. A prototype implementation of the algorithm is undergoing trials in the clinical routine of radiology department of major Korean hospital.

  • PDF

근관장 측정시 구내 디지털 방사선 시스템인 Digora System의 정확도에 관한 연구 (THE ACCURACY OF DIGORA SYSTEM, AN INDIRECT DIGITAL RADIOGRAPHIC SYSTEM, IN DETERMINING THE WORKING LENGTH)

  • 한상욱;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.347-357
    • /
    • 1997
  • An accurate working length is an essential factor in the success of endodontic treatment. There are several methods for determining working length; electronic apex locator, tactile sense by clinician, and radiography. Among these methods, the most commonly used method is radiography. But this method requires excessive radiation, long developing time, and many equipments. In additon, it could give an image distortion and two dimensional image. To improve these disadvantages, an intraoral digital radiographic system (Digora$^{(R)}$) which use an imaging plate instead of a film, was developed. The purpose of this investigation was to compare Digora imaging with conventional radiography in determining the working length. Maxillary first or second molars of human dried skull were used. Files were inserted into canals at randomly selected lengths, from 2mm short of the radiographic apex to 2rnm beyond. Radiographs and Digora images(Digora positive and Digora negative) were evaluated to determine the adjustment needed to place the file 0.5mm from the radiographic apex. The results were as follows ; 1. There was no significant difference in accuracy between those evaluated in ${\pm}0.5mm$ and those accurately evaluated in the 3 images. 2. When comparing the accuracy of each image without distinguishing the 3 images, in the group accurately determined within ${\pm}0.5mm$, the mesiobuccal group showed significantly higher accuracy compared to the palatal group(p<0.05).

  • PDF

CR 시스템을 이용한 방사선 종양학과의 Filmless 환경 구축 (Setting Up a CR Based Filmless Environment for the Radiation Oncology)

  • 김동영;이지혜;김명수;하보람;이천희;김소영;안소현;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제22권3호
    • /
    • pp.155-162
    • /
    • 2011
  • 방사선치료를 위한 아날로그영상기반의 시뮬레이터와 의료용 선형가속기로 이루어진 시스템을 X-ray 필름을 Computed Radiography (CR)로 교체하여 디지털영상기반의 시스템으로 개선하였다. 장비교체를 최소화하였고 기존의 치료과정과 유사하도록 하여 사용자들이 짧은 시간에 적응할 수 있도록 하였다. 필름카세트와 필름현상기는 CR카세트와 CR리더기로 대신하였고, ViewBox는 소형PC와 모니터로 대체되었다. 디지털영상의 장점을 충분히 활용하기 위해 방사선종양학과에 적합한 Viewer 소프트웨어를 개발하여 업무의 편리성과 효율성을 도모하였다. Viewer 소프트웨어는 2개의 이미지를 동시에 볼 수 있으며, 이들 영상의 비교도 가능하다. 다양한 검색기능과 Contouring 기능, 윈도우폭/레벨 조절기능을 갖추었다. 업무의 중단이 없도록 하기 위해 1주일간 기존 필름과 CR을 공동으로 운용하며 문제점을 수정한 후 필름시스템을 제거하고 CR시스템을 운용하였다. CR시스템은 안정적으로 운용되고 있으며, 본격적으로 CR시스템이 이용되면서 사용자로부터 제기되는 여러 요구사항을 반영하여 기능을 개선하였다.

디지털 방사선 검사장치(DR)의 AC 서보 시스템 설계 (AC Servo System Design of Digital Radiography Equipment)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.133-138
    • /
    • 2022
  • 디지털 방사선 검사장 치는 인간의 생명을 다루는 의료장치로 안정성과 고신뢰성이 필요하지만 이러한 시스템은 현재 최첨단 기술로 일본을 비롯한 유럽제품에 의해서 국내시장은 거의 점유된 실정이다. 따라서 상당한 부분 값비싼 수입품에 의존하고 있는 의료기기의 국산품 대체는 물론, 보다 경제적이고 조작하기 쉬운 사용자 위주의 제품을 개발, 정확한 진단을 이끄는 장치의 생산을 위한 연구와 개발이 필요하다. 특별히 디지털 X-ray 시스템 중에서 전동기 구동기술과 기계장치 개발 관련 메카트로닉스 기술은 국내에 어느 정도 성숙되어 있는 단계로 본 논문에서는 디지털 방사선 검사 장치(DR)의 전동기 서보 시스템 설계를 통하여 제어기법과 성능을 확인하고자 한다. 본 논문에서는 촬영용도에 부합하는 디지털 방사선 검사용 AC 서보전동기의 선정과 변환장치 및 제어기법을 적용하여 성능을 확인하고 문제점을 개선함에 있다.