• Title/Summary/Keyword: Digital radiation

Search Result 571, Processing Time 0.023 seconds

A Radiation-hardened Model Design of CMOS Digital Logic Circuit for Nuclear Power Plant IC and its Total Radiation Damage Analysis (원전용 IC를 위한 CMOS 디지털 논리회로의 내방사선 모델 설계 및 누적방사선 손상 분석)

  • Lee, Min-Woong;Lee, Nam-Ho;Kim, Jong-Yeol;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.745-752
    • /
    • 2018
  • ICs(Integrated circuits) for nuclear power plant exposed to radiation environment occur malfunctions and data errors by the TID(Total ionizing dose) effects among radiation-damage phenomenons. In order to protect ICs from the TID effects, this paper proposes a radiation-hardening of the logic circuit(D-latch) which used for the data synchronization and the clock division in the ICs design. The radiation-hardening technology in the logic device(NAND) that constitutes the proposed RH(Radiation-hardened) D-latch is structurally more advantageous than the conventional technologies in that it keeps the device characteristics of the commercial process. Because of this, the unit cell based design of the RH logic device is possible, which makes it easier to design RH ICs, including digital logic circuits, and reduce the time and cost required in RH circuit design. In this paper, we design and modeling the structure of RH D-latch based on commercial $0.35{\mu}m$ CMOS process using Silvaco's TCAD 3D tool. As a result of verifying the radiation characteristics by applying the radiation-damage M&S (Modeling&Simulation) technique, we have confirmed the radiation-damage of the standard D-latch and the RH performance of the proposed D-latch by the TID effects.

Spectral Backward Radiation Profile (주파수 대역별 후방복사 프로파일)

  • Kim, Hak-Joon;Kwon, Sung-Duk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.362-367
    • /
    • 2005
  • Ultrasonic backward radiation profile is frequency-dependent when the incident region has deptional gradient of acoustical properties or multi-layers. Until now, we have measured the profiles of principal frequencies of an used transducers so that it was not easy to characterize the frequency dependence of the SAW(surface acoustic wave) from the backward radiation profile. We tried to measure the spectral backward radiation profiles using DFP(digital filer package) in a Lecroy DSO(digital storage oscilloscope). The measured spectral profiles showed that the steel specimen of #1200 surface treatment have 2% SAW velocity dispersion of the loaded case and the severly rusty steel specimen have the very big changes in the shape and pattern of the spectral profile. It is concluded that the spectral backward radiation profiles could be very effective tool to evaluate the frequency dependence of surface area.

Evaluation of Scatter Radiation in Digital Radiological Condition by using Photostimulated Luminescence (BaFBr:$Eu^{2+}$) (휘진성 형광체 (BaFBr:$Eu^{2+}$)를 이용한 영상의학분야에서 산란선 특성에 관한 평가)

  • Min, Jung-Whan;Han, Seong-Gyu;Kim, Jung-Min;Lee, Joo-Ah;Kim, Ki-Won;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.85-91
    • /
    • 2014
  • The purpose of this study is evaluated scatter radiation in digital radiological condition by using photo-stimulated luminescence (BaFBr:$Eu^{2+}$). Experiment condition changed kVp (from 50 kVp to 120 kVp), filed size (from $4{\times}4cm^2$ to $26{\times}26cm^2$) and phantom thickness (from 1 cm to 15 cm). This method was analysed ImageJ and characteristic curve of CR. This results was scatter radiation to primary radiation ratio increased from 50 kVp to 70 kVp, and it was fixed at over 80 kVp. The scatter radiation to primary radiation ratio are increased according to increasing the ratio of field size. Scatter radiation is also increased by increasing the phantom thickness.

Study on Radiation Dose in the Medical Image Data Display Method - Focused on the DICOM Standard (의료영상 데이터에서의 피폭선량 표시 방법에 관한 고찰: DICOM 표준을 중심으로)

  • Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.483-489
    • /
    • 2015
  • DICOM (Digital Imaging and Communications in Medicine) standards are generally introduced as de facto and de jure standards in modern medical imaging devices to store and to transmit medical image information. DICOM Dose Structured Report (DICOM dose SR) is implemented to report radiation exposure information in image acquiring process. and DIOCM Modality Performed Procedure Step (DICOM MPPS) is also partly used to report this exposure with the information in its DICOM tag. This article is focused on three type of radiation exposure information of DICOM standards, 1) DICOM dose SR, 2) DICOM MPPS and 3) Radiation Exposure Monitoring(REM) profile by Integrating the Healthcare Enterprise(IHE), to study on radiation exposure reporting. Healthcare facility and its staff of medical imaging related to radiation exposure should have a deep understanding of radiation exposure, and it required a standards to enhance the quality control of medical imaging and the safety of patients and staffs. Staff member have to pay attention on radiation exposures and controling processes from the purchasing stage of X-ray devices.

A study of an environmental radiation monitoring system(ERMS) using digital single channel analyzer(SCA) and dose conversion unit(DCU) (디지털 SCA와 DCU를 이용한 환경방사선 감시기에 관한 연구)

  • 오길환;우희곤;이쾌희;하달규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1372-1375
    • /
    • 1996
  • In this paper, we developed and ERMS, which monitors radiation continuously in the vicinity of the nuclear power plant not only to intend health and security of the adjacent residents but also to prevent environmental pollution. Especially, applying digital DCU and SCA which are easy to control and accurate, we obtained good results.

  • PDF

A Study on the Electromagnetic Wave Measurement in Diagnostic Imaging Equipment (진단용 영상장치에서 전자파 측정에 관한 고찰)

  • Eo, Yun-Gi
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.39-44
    • /
    • 2005
  • Purpose of this research is that if Radiographer has focused on Radiation exposure research until now, he should realize that always exposed by Electro Magnetic Wave at given working environment And also, another purpose is that to minimize damage with measuring Electro Magnetic Wave which is happened area and distance of Radiation Control System and High Voltage Equipment, check occurrence rate and minimize damage from it.

  • PDF

Recent Advances in Radiation-Hardened Sensor Readout Integrated Circuits

  • Um, Minseong;Ro, Duckhoon;Kang, Myounggon;Chang, Ik Joon;Lee, Hyung-Min
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.3
    • /
    • pp.81-87
    • /
    • 2020
  • An instrumentation amplifier (IA) and an analog-to-digital converter (ADC) are essential circuit blocks for accurate and robust sensor readout systems. This paper introduces recent advances in radiation-hardening by design (RHBD) techniques applied for the sensor readout integrated circuits (IC), e.g., the three-op-amp IA and the successive-approximation register (SAR) ADC, operating against total ionizing dose (TID) and singe event effect (SEE) in harsh radiation environments. The radiation-hardened IA utilized TID monitoring and adaptive reference control to compensate for transistor parameter variations due to radiation effects. The radiation-hardened SAR ADC adopts delay-based double-feedback flip-flops to prevent soft errors which flips the data bits. Radiation-hardened IA and ADC were verified through compact model simulation, and fabricated CMOS chips were measured in radiation facilities to confirm their radiation tolerance.

Radiation detector material development with multi-layer by hetero-junction for the reduction of leakage current (헤테르접합을 이용한 누설전류 저감을 위한 다층구조의 방사선 검출 물질 개발)

  • Oh, Kyung-Min;Yoon, Min-Seok;Kim, Min-Woo;Cho, Sung-Ho;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using a multi-layer technique to decrease dark current. High efficiency materials in substitution for Amorphous Selenium(a-Se) have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using PN junction or Hetero junction already used as solar cell, semiconductor. Particle-In -Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in Particle-In -Binder method. To make up for the weak points, multi-layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity, signal linearity is measured to evaluate multi-layer radiation sensor material.

  • PDF

A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit (C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교)

  • Kim, Jin-Su;Woo, Bong-Cheol;Kim, Sung-Jin;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF