• Title/Summary/Keyword: Digital medicine

Search Result 1,644, Processing Time 0.037 seconds

Acoustic Analysis for Thermal Environment-related Vocalizations in Laying Hens (산란계의 열환경별 특이음에 대한 음성학적 분석)

  • Jeon, J.H.;Yeon, S.C.;Ha, J.K.;Lee, S.J.;Chang, H.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.697-702
    • /
    • 2005
  • The aim of this study was to divide vocalizations of laying hens (Hy-Line Brown) into general vocalizations (GVs), heat stress-related vocalization (HSV), and cold stress-related vocalizations (CSVs) and to determine if they are classified by the discriminant function analysis method. Thirty laying hens, 65-wk-old, were recorded using digital video recorders 2 times from 10:00 to 14:00 h in each thermal environment (thermoneutral: $22.0{\pm}1.8^{\circ}C$, too hot: $32.0{\pm}2.0^{\circ}C$, too cold: $8.0{\pm}1.9^{\circ}C)$ after a 7 day acclimation period. When the laying hens were not recorded, they were kept in thermoneutral conditions. The GVs, HSV, and CSVs were divided based on the shapes of spectrums and spectrograms. The GVs, HSV, and CSVs were identified as 5, 1, and 3 types, respectively. Pitch, intensity, duration, formant 1, formant 2, formant 3, and formant 4 among the thermal environment-related vocalizations were significantly different (P<0.001). The discrimination rate determined by discriminant function analysis was 86.2%. These results suggest that HSV and CSVs are present and may be used as an indicator of the thermal environment.

Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement - (중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 -)

  • Song, Byung Chul;Park, Yong Joon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.1041-1051
    • /
    • 2003
  • Neutron induced prompt gamma activation analysis (PGAA) offers a nondestructive, sensitive and relatively rapid method for the determination of trace and major elements and is proven to be convenient for online analysis of minerals, metals, coal, cement, petrochemical, coating, paper as well as many other materials and products. The technique has found many uses in medicine, industry, research, security and the detection of contraband items. This report reviews the present status and future trends of the PGAA techniques. Requirements for the system are neutron source, high resolution HPGe detectors with a high-voltage power supply, an amplifier, analog-to-digital converter, and a multichannel analyzer for the detection and measurement of prompt ${\gamma}$-ray emit form the neutron capture elements. Introducing a ${\gamma}$-${\gamma}$ coincidence system also improves the quality of the ${\gamma}$-ray spectrum by suppressing the background created from the Compton scattering of high energy prompt ${\gamma}$-rays. A PGAA system using a $^{252}Cf$ neutron source is currently under construction for the on-line measurement of several elements in aqueous samples at KAERI. The system can be applied for the detection of chemical weapons and explosives as well as various narcotics.

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

The study on toothbrush filaments (칫솔 강모 형태에 관한 연구)

  • Han, Seung-Min;Yang, Seung-Min;Lee, Young-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Choi, Sang-Mook;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.857-864
    • /
    • 2002
  • The aim of this study is to investigate the end of filaments of the different toothbrushes in the market through the stereomicroscope and to evaluate the % of rounded-end filaments considered to be acceptable. 9 brands, total 11 type toothbrushes were tested. 2 toothbrushes of each type which is marked as rounded-end filaments were tested. The toothbrushes which are not marked as rounded-end filaments were excluded. The domestic as well as foreign toothbrushes which are familiar to consumers were tested. 2 tufts of each toothbrushes were cut and examined by stereomicroscope using $40{\times}$ magnification. The procedure was carried out with blind-technique, and the digital photographs were taken. Besides the % of rounded-end filaments, total tufts number, material of the tuft, stiffness, and other special characteristics were recorded. By the classification of Silverstone and Featherstone, rounded-end filaments were examined and counted. The results shows that there are different range of rounded-end filaments according to the toothbrush types(17.7%-91.2%). Atman toothbrush has the most rounded-end filaments(91.2%) among the observed toothbrushes, and the Advantage Plus(Ora1-B) has the next(86.75%). E-Clean #411 has the least(17.70%) and E-Clean #410 of the same brand has also low % rounded-end filaments(20.60%). While G.U.M #409(Butler) has 67.90% rounded-end filaments, G.U.M #471 of the Same brand has comparative low 41.83% rounded-end filaments. 4 types of total 11 have the rounded-end filaments over 80%, however other 4 types have under even 50%. Considering that the correct brushing habit with a toothbrush which has rounded-end filaments can protect the gingival injury and tooth abrasion, it is thought that we dentists need to give the correct information about toothbrush to the patients

AN EXPERIMENTAL STUDY ON THE HEALING PROCESS OF TOOTHASH, PLASTER OF PARIS AND AUTOGENOUS BONE COMPOSITE GRAFTING IN DOGS (치아회분과 석고혼합제재 매식과 자가골 동시 이식후 치유과정에 관한 실험적 연구)

  • Yeo, Hwan-Ho;Jung, Jae-Hun;Lee, Sang-Ho;Kim, Heung-Jung;Kim, Young-Kyun;Lim, Seung-Cheul;Sul, In-Tak
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.1
    • /
    • pp.1-14
    • /
    • 2000
  • The purpose of this study was to evaluate the efficacy of adding autogenous bone to the toothash-plaster mixture in the healing process of bone. Full-thickness round osseous defects with the diameter of 20mm were made at the calvarial bone of adult dogs (n=19) bilaterally, which were thought to be critical size defect. The right defects were repaired with the toothash-plaster mixture plus autogenous bone (compressed volume 0.3cc) and the left defects with only toothash-plaster mixture. At 2-, 4-, 8-, 12- and 20- week after implantation, dogs were sacrificed and evaluated the osseous healing of bony defects clinically, radiographically, and microscopically. The results were as follows; 1. At the clinical observation, the wound healed very well without any problem except severe swelling in the early period after operation. Slight depression was recognized at the both sides when the portions of cranial defect were palpated. 2. There were statistically significant differences between toothash-plaster mixture groups and autogenous bone added groups at the same period, and among the groups in the bone density of the digital radiograms (P<0.001). There was a tendency that bone density was increasing with time. 3. In light microscopic examination, new bone formation was more active in the autogenous bone added groups than toothash-plaster mixture groups at the early period after implantation but there is little difference at 20-week after implantation. 4. In fluorescent microscopic examination, the fluorescent band could be observed at the area of active bone formation and the band was more distinct in the autogenous bone added groups then toothash-plaster mixture groups. 5. In transmitted electron microscopic examination, organelles such as rER, Golgi complex and secretory granule and osteoblast were observed. In summary higher volume ratio of autogenous bone is needed to improve the bone healing in that there is little difference between toothash-plaster mixture group and autogenous bone added group at the 20-week after implantation in spite of new bone formation was more active in the autogenous bone added groups than toothash-plaster mixture groups at the early period after operation.

  • PDF

STUDY ON ADAPTABILITY OF RUBBER DAM CLAMPS ON PRIMARY SECOND MOLARS IN KOREAN CHILDREN (한국인 소아에서 제2유구치에 대한 러버댐 클램프의 적합도에 관한 연구)

  • Park, Mirae;Mah, Yon-Joo;Ahn, Byung Duk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.2
    • /
    • pp.98-105
    • /
    • 2013
  • The purpose of this study was to investigate the mesiodistal widths at the cervical level of primary second molars in Korean children, and to compare them with commercial rubber dam clamps commonly used in pediatric dentistry. Dental casts of 115 primary and mixed dentition children were studied. Cervical mesiodistal width (C-MD) was measured at the clinical cervical level of each primary second molar from buccal and lingual sides using a digital caliper (Absolute, Mitutoyo, Kawasaki, Japan). The data were compared with mesiodistal widths of rubber dam clamps #203/204, #10/11, and #205 (Dentech, Japan). C-MDs of primary mandibular second molars were larger than those of primary maxillary second molars, and C-MDs at buccal sides were larger than those of lingual sides. All C-MDs showed statistically significant discrepancies to corresponding widths on clamps (p < 0.05). However the amount of discrepancy was mild in maxillary teeth, while up to 1 mm of discrepancy was shown in mandibular teeth. In conclusion, C-MDs measured in this study imply a relatively fair fit of #10/#11 or #203/#204 clamps on primary maxillary second molars, while suggesting our need for a better clamp with proper size for primary mandibular second molars.

An Analysis of the Research Trend of the Participants in Emotional Science in Korea (한국의 감성과학 연구참여분야 동향 분석)

  • Park, Seong-Bae
    • Science of Emotion and Sensibility
    • /
    • v.15 no.1
    • /
    • pp.29-36
    • /
    • 2012
  • This study aims to analyse the research trend of the participants in Emotional Science in Korea and to suggest a desirable direction of research. I analysed the 1,262 articles published in Korean Journal of the Science of Emotion and Sensibility from 2000 to 2011 according to fields of study and keywords. The findings from the study are as follows. In the fields of study regarding Clothing Design, Psychology, Medicine, Visual Media, Brain Science they are still the top rated categories amongst participants. With the participation of Industrial Engineering and Ergonomics they have shown a meaningful difference depending on governmental support such as G7 Project. The problem with Industrial Design is that the majority of studies have been performed alone, and they have many keywords which are not related with Emotional Science. However, 31 new fields of study have been added to the research making the findings more desirable considering that Emotional Science is typical interdisciplinary filed of study. I hope that this study will provide basic data which can be used to promote the interdisciplinary research between the different fields of study in order to generate significant synergy.

  • PDF

Development and Verification of Real Time Subjective Sensibility Evaluation System

  • Chung, Soon-Cheol;Min, Byung-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.355-361
    • /
    • 2003
  • In the present study, a new Real Time Subjective Evaluation (RTSSE) system was developed. The system is composed of two parts: a sensibility input part and sensibility evaluation part. The sensibility input part receives values, which are recorded on an input board using a stylus and digital tablet, from each subject's evaluation of his/her own subjective sensibility towards a particular stimulus. The sensibility evaluation part displays the level of pleasantness and arousal on one or two dimensions in real time. An experiment was conducted in order to investigate the feasibility and effectiveness of the RTSSE system. The present study compared Galvanic Skin Response (GSR) with the RTSSE by presenting 28 subjects in their 20s with pictures arousing either positive or negative sensibility. Following the experiment, an off-line subjective assessment using a questionnaire was given to the same subjects. According to the correlation coefficients, changes in subjective sensibility caused by the positive visual stimulus were related more closely to GSR, from the positive visual stimulus, and changes in subjective sensibility caused by the negative visual stimulus were related more closely to GSR from the negative visual stimulus. The questionnaire results showed marked similarity to the average responses of the RTSSE. In conclusion, the most remarkable characteristic of the present system is that it not only assesses the average sensibility when stimuli are presented, but also shows the changing strength of sensibility over time.

Interoperability Framework between GRID and PACS based on Web Services (웹서비스 기반의 Grid-PACS 상호운용성 프레임워크)

  • Lee, Bong-Hwan;Cho, Hyun-Sug
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.8
    • /
    • pp.1799-1808
    • /
    • 2010
  • Recently the increasing collaborative research requires the remote medical and clinical data sharing and access of external institutions. In this paper, an interoperability framework between Grid and PACS using Web services is proposed and implemented in order to provide flexible and efficient medical data management. The Digital Imaging and Communications in Medicine(DICOM) standard defines medical image data exchange and transfer between PACSs and image databases. However, medical data exchange between hospitals is limited within the trusted and static environments. Moreover, DICOM does not provide medical data management and the Grid middleware does not include standard toolkit to access DICOM data. To address this issue, a Web services-based Grid Service Mediator (WGSM) which provides PACS integration and medical image data management is developed. The WGSM consists of several service mediators such as compress mediator, GridFTP mediator, RFT mediator, MyProxy mediator, MDS mediator, and RLS mediator and others. The proposed Web services-based framework provides user authentication and secure data access between PACSs in collaborative environments. In particular, the WGSM allows ordinary users to access remote PACS data in a simple and efficient manner without any the knowledge about underlying Grid middleware.

An Investigation on Intellectual Structure of Social Sciences Research by Analysing the Publications of ICPSR Data Reuse (ICPSR 데이터 재이용 저작물 분석을 통한 사회과학 분야의 지적구조 분석)

  • Chung, EunKyung
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.52 no.1
    • /
    • pp.341-357
    • /
    • 2018
  • Due to the paradigm of open science and advanced digital information technology, data sharing and re-use have been actively conducted and considered data-intensive in a wide variety of disciplines. This study aims to investigate the intellectual structure portrayed by the research products re-using the data sets from ICPSR. For the purpose of this study, a total of 570 research products published in 2017 from the ICPSR site were collected and analyzed in two folds. First, the authors and publications of those research products were analyzed in order to show the trends of research using ICPSR data. Authors tend to be affiliated with university or research institute in the United States. The subject areas of journals are recognized into Social Sciences, Health, and Psychology. In addition, a network with clustering analysis was conducted with using co-word occurrence from the titles of the research products. The results show that there are 12 clusters, mental health, tabocco effect, disorder in school, childhood, and adolescence, sexual risk, child injuries, physical activity, violent behavior, survey, family role, women, problem behavior, gender differences in research areas. The structure portrayed by ICPSR data re-uses demonstrates that substantial number of studies in Medicine have been conducted with a perspective of social sciences.