• 제목/요약/키워드: Digital intraoral scanner

검색결과 98건 처리시간 0.024초

Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition

  • Seo Young Shin;Yong Kwon Chae;Ko Eun Lee;Mi Sun Kim;Ok Hyung Nam;Hyo-seol Lee;Sung Chul Choi
    • 대한소아치과학회지
    • /
    • 제51권1호
    • /
    • pp.55-65
    • /
    • 2024
  • This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.

디지털 기술을 활용한 전악 고정성 보철 수복 증례 (Application of various digital technique on full mouth rehabilitation: A case report)

  • 배민수;송광엽;안승근;박주미;이정진;서재민
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.43-54
    • /
    • 2021
  • 디지털기술의 급격한 발전으로 보철 수복치료에 있어서도 많은 기술들이 활용되고 있다. 특히 최근에는 구강스캐너와 3D printing 기술이 광범위하게 사용되고, 더 나아가 안면스캔 기술 또한 접목되어 활용되고 있다. 본 증례는 37세 여성환자에서 전통적인 방식으로 제작되고 장착되어 충분히 평가된 전악 고정성 임시수복상태를 구강스캐너와 안면스캐너, 3D printing 등의 다양한 디지털 기술을 활용하여 안모와 조화를 이루는 최종보철물로 이행하는 과정을 거쳤다. 이를 통해 안정적인 교합을 회복하고 기능적, 심미적으로 만족할만한 결과를 얻었기에 보고하는 바이다.

사용자 친화적 인체공학에 따른 구내스캐너 디자인에 대한 고찰 (The user-friendly, ergonomic design aspect of recent intraoral scanners: a literature review)

  • 박혜난;김원희;임영준;이원진;한중석;이승표
    • 구강회복응용과학지
    • /
    • 제31권3호
    • /
    • pp.221-230
    • /
    • 2015
  • 최근 치과 인상 채득법은 인상재를 사용하는 전통적 방법에서 구내스캐닝을 이용한 디지털 인상방법으로 빠르게 발전하고 있다. 현재 치과시장에는 적어도 10개 이상의 구내스캐너가 있다. 하지만 기술과 디자인이 빠르게 발전하는 가운데 다양한 제품들 중 사용자가 합리적인 선택을 할 수 있는 기준이 명확하지 않다. 이 문헌고찰에서는 다양한 인체공학적 디자인 관련 논문을 토대로 한 근거자료를 통하여 사용자의 입장에서 가장 사용이 편리하고 알맞은 인체공학적 디자인을 제안하고자 한다. 이를 통하여 구내스캐너의 인체공학적 디자인의 중요성을 한번 더 확인하고 알맞은 인체공학적 구내스캐너의 제시를 통하여 사용자(치과의사)들의 근골격의 질환과 장애를 예방하고자 한다.

총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰 (Application and consideration of digital technology for removable complete denture)

  • 이정진;송광엽;박주미
    • 대한치과의사협회지
    • /
    • 제57권9호
    • /
    • pp.534-543
    • /
    • 2019
  • Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

  • PDF

구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례 (Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report)

  • 장윤정;김홍준;송미경;문지은;이한라;박찬익
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.234-243
    • /
    • 2015
  • 디지털 기술의 발달로 무치악 부위의 임플란트 수복 시 그 진단과 치료 과정 전반에 걸쳐 구강 내 3차원 정보를 데이터화하여 보철물을 제작하는 것이 가능해졌다. 전통적인 인상채득 방식을 이용하여 모델을 만들고 이것을 스캔하여 보철물을 제작하던 CAD/CAM 이용 방식에서 벗어나 디지털 인상 코핑(scanbody)을 사용함으로써 모델 없이 디지털 인상을 채득하고 임플란트 임시 보철물 및 해부학적 지대주를 제작하는 술식으로 변화하고 있다. 그러나 아직 이러한 술식은 활발히 이루어지고 있지 않으며 특히 심미성이 요구되어 연조직 외형의 인기가 중요한 상악 전치부 임플란트 즉시 부하에서의 사용은 그 사례가 많지 않다. 이에 따라 본 증례 보고에서는 3명의 상악 전치부 단일 임플란트 수복 환자에서 디지털 인상 코핑(scanbody)을 체결한 후 구강 내 스캐너인 CEREC Omnicam (Sirona, Bensheim, Germany) 또는 Trios (3shape, Copenhagen, Denmark)로 디지털 인상채득을 통해 임플란트 지대주 및 임시 보철물을 제작하였다. 그 결과 디지털 인상채득을 통한 편리성, 정확성 그리고 최종 보철물의 양호한 심미성을 얻어 보고하고자 한다.

스캔이 가능한 치유지대주를 이용한 구치부 단일 임플란트 수복 증례 (Posterior single implant prosthesis using scannable healing abutment)

  • 김성민;이규복
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.432-438
    • /
    • 2019
  • 임플란트 보철 치료의 성공에 정확한 인상 채득은 매우 중요한 과정이다. 이러한 임플란트 보철의 인상을 채득하는 방법에는 임프레션 코핑과 인상재를 이용한 전통적인 방법과 구강 스캐너와 디지털 인상 코핑(scanbody)을 이용한 디지털 인상채득법이 있다. 하지만 인상용 코핑과 scanbody는 모두 구강 내 치유 지대주(healing abutment)를 제거하고 장착해야 한다. 때문에 술자는 치유 지대주와 임프레션 코핑 또는 scanbody를 여러 번 체결하고 제거하는 과정을 반복해야 한다. 뿐만 아니라 임프레션 코핑 또는 scanbody는 교합면보다 높게 솟아 있어 환자는 지속적으로 개구 상태를 유지해야 하는 불편을 주기도 한다. 이러한 기존의 방법을 극복하고자 최근에는 치유 지대주에 scanbody의 스캔 가능 부분(scannable part)을 부여하여 치유 지대주를 제거할 필요 없이 구강 내에서 직접 구강 스캐너로 스캔이 가능한 치유지대주(scannable healing abutment)가 소개되었다. 스캔이 가능한 치유지대주를 이용하여 구치부 단일 임플란트를 수복한 증례를 소개하고자 한다.

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권4호
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study

  • Dina Mohamed Ahmed Elawady;Wafaa Ibrahim Ibrahim;Radwa Gamal Ghanem;Reham Bassuni Osman
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권4호
    • /
    • pp.201-211
    • /
    • 2024
  • PURPOSE. The aim of this prospective clinical study was to compare the influence of palatal vault forms on accuracy and speed of intraoral (IO) scans in completely edentulous cases. MATERIALS AND METHODS. Based on the palatal vault form, participants were divided into three equal groups (n = 10 each); Class I: moderate; Class II: deep; Class III: flat palatal vault. A reference model was created for each patient using polyvinylsiloxane impression material. The poured models were digitized using an extraoral scanner. The resultant data were imported as a solid CAD file into 3D analysis software (GOM Inspect 2018; Gom GmbH, Braunschweig, Germany) and aligned using the software's coordinate system to determine its X, Y, and Z axes. Five digital impressions (DIs) of maxilla were captured for each patient using an intraoral scanner (TRIOS; 3Shape A/S, Copenhagen, Denmark) and the resultant Standard Tessellation Language (STL) scan files served as test models. Trueness was evaluated by calculating arithmetic mean deviation (AMD) of the vault area between reference and test files while precision was evaluated by calculating AMD between captured scans to measure repeatability of scan acquisition. The scan time taken for each participant was also recorded. RESULTS. There was no significant difference in trueness and precision among the groups (P = .806 and .950, respectively). Average scan time for Class I and III palatal vaults was 1 min 13 seconds and 1 min 37 seconds, respectively, while class II deep palatal vaults showed the highest scan time of 5 mins. CONCLUSION. Palatal vault form in edentulous cases has an influence on scan time. However, it does not have a substantial impact on the accuracy of the acquired scans.

임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고 (Axial displacement in single-tooth implant restoration: Case report)

  • 정승회;김선재;장재승
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.126-133
    • /
    • 2021
  • 여러 연구에서 임플란트 지지 보철물의 수직 침하에 대해 보고되고 있지만, 구강내 임플란트 지지보철물의 기능 시 수직침하 양상에 대해서는 알려진 바 없다. 본 증례에서는 2명의 환자에서 구치부 단일 치아 임플란트 지지 보철물의 3차원적인 변화를 평가하였다. 내부연결형 임플란트를 식립하였으며 통상적인 방법으로 Screw-Cement Retained Prosthesis(SCRP) 형태의 보철물을 제작해 장착하였다. 구강스캐너(Cerec Omnicam, Dentsply Sirona, USA)를 이용해 보철물 장착 시, 장착 1주, 1개월, 1년 후 구강 스캔을 시행하였으며 디지털 분석 프로그램(Geomagic Control X, 3D systems, USA)을 이용해 기간에 따른 위치 변화를 3차원적으로 평가하였다. 인접 치아를 기준으로 보철물 장착 후 임상적인 위치 변화가 나타났으며 변화량은 시간이 지남에 따라 증가하였다.

A novel method for testing accuracy of bite registration using intraoral scanners

  • Lydia Kakali;Demetrios J. Halazonetis
    • 대한치과교정학회지
    • /
    • 제53권4호
    • /
    • pp.254-263
    • /
    • 2023
  • Objective: The evidence on the accuracy of bite registration using intraoral scanners is sparse. This study aimed to develop a new method for evaluating bite registration accuracy using intraoral scanners. Methods: Two different types of models were used; 10 stone models and 10 with acrylic resin teeth. A triangular frame with cylindrical posts at each apex (one anterior and two posteriors) was digitally designed and manufactured using three-dimensional (3D) printing. Such a structure was fitted in the lingual space of each maxillary and mandibular model so that, in occlusion, the posts would contact their opposing counterparts, enforcing a small interocclusal gap between the two arches. This ensured no tooth interference and full contact between opposing posts. Bite registration accuracy was evaluated by measuring the distance between opposing posts, with small values indicating high-accuracy. Three intraoral scanners were used: Medit i500, Primescan, and Trios 4. Viewbox software was used to measure the distance between opposing posts and compute roll and pitch. Results: The average maximum error in interocclusal registration exceeded 50 ㎛. Roll and pitch orientation errors ranged above 0.1 degrees, implying an additional interocclusal error of around 40 ㎛ or more. The models with acrylic teeth exhibited higher errors. Conclusions: A method that avoids the need for reference hardware and the imprecision of locating reference points on tooth surfaces, and offers simplicity in the assessment of bite registration with an intraoral scanner, was developed. These results suggest that intraoral scanners may exhibit clinically significant errors in reproducing the interocclusal relationships.