• Title/Summary/Keyword: Digital imaging

Search Result 1,503, Processing Time 0.032 seconds

A Convergence Study on the 5-axis Machining Technology using the DICOM Image of the Humerus Bone (위팔뼈 의료용 디지털 영상 및 통신 표준 영상을 이용한 5축 가공기술의 융합적 연구)

  • Yoon, Jae-Ho;Ji, Tae-Jeong;Yoon, Joon;Kim, Hyeong-Gyun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.115-121
    • /
    • 2017
  • The present study aimed to obtain basic knowledge of a customized artificial joint based on the convergence research of Digital Imaging and Communications in Medicine(DICOM) and 5-axis machining technology. In the case of the research method, three-dimensional modeling was generated based on the medical image of the humerus bone, and the shape was machined using a chemical wood material. Then, the anatomical characteristics and the modeling machining computation times were compared. The results showed that the Stereolithography (STL) modeling required twice more time for semi-finishing and 10 times more time for finishing compared to the Initial Graphics Exchange Specification(IGES) modeling. For the 5-axis machining humerus bone, the anatomical structures of the anatomic neck, greater tubercle, lesser tubercle, and intertubercular groove were similar to those in the three-dimensional medical image. In the future, the convergence machining technology, where 5-axis machining of various structures(e.g., the surgical neck undercut of the humerus bone) is performed as described above, can be efficiently applied to the manufacture of a customized joint that pursues the precise model of a human body.

Effects on the Thermal Changes of the Ankie Region Following Acupuncture on Wu-Hu (오호혈(五虎穴)이 족과부(足踝部) 체표온도변화(體表溫度變化)에 미치는 영향(影響))

  • Kim, Hyun-Jung;Byun, Jae-Young;Ahn, Soo-Gi;Lee, Geon-Mok;Park, Yong-Hyun;Kim, Kyung-Sik
    • Journal of Acupuncture Research
    • /
    • v.18 no.1
    • /
    • pp.40-49
    • /
    • 2001
  • Background and Purpose : There have been many studys about the relationship between the meridians and the acupoints of the twelve meridians, but no study about the extra points. To verify Dong-Shi acupoints, a kind of extra points, we studied the effects on the thermal changes of the ankle region following acupuncture on the Wu-Hu. Object and Methods : This study was researched into clinical statistics for 45 healthy normal students. The object was divided into two groups. One was the control group and the other was the acupuncture group. The acupuncture group was divided into two groups ; ACU-up : The class of ascent thermal change among acupuncture group. ACU-dn : The class of descent thermal change among acupuncture group. First, in the control group, we took a picture at the ankle region(BL60, BL62, GB40, ST41) without any stimulation with the Digital Infrared Thermal Imaging System and did after 10 minutes respectively. Second, in the acupuncture group, we took a picture without any stimulation and then acupuncture on Wu-Hu and took a picture after 10 minutes in the same way respectively. Results : 1. In the control group, average thermal change of BL60, BL62, GB40 and ST41 was decreased(about $0.2^{\circ}C$) after 10 minutes. 2. The skin temperature of all measured parts was significantly lower in the ACU-dn group after 10 minutes. 3. There were no significant differences of thermal change between the control and the acupuncture group, between the control and ACU-up group after 10 minutes. Conclusion : This result indicated that the acupuncture on the Wu-Hu was effective at the ankle region. And so the more study is needed continuously.

  • PDF

Clinical Observation of Acupuncture and Nerve Block Treatment for Adhesive Capsulitis Patients (유착성 관절낭염에 대한 침 및 신경차단술 처치의 임상적 관찰)

  • Nam, Dong-Woo;Lim, Sabina;Kim, Jong-In;Kim, Keon-Sik;Lee, Doo-Ik;Lee, Jae-Dong;Lee, Yun-Ho;Choi, Do-Young
    • Journal of Acupuncture Research
    • /
    • v.24 no.4
    • /
    • pp.143-155
    • /
    • 2007
  • Objectives: To observe the effect of acupuncture and nerve block combination treatment on adhesive capsulitis patients. Methods : 59 voluntary patients were randomly assigned to acupuncture treatment group(E group, n=22), nerve block treatment group(W group, n=17) and acupuncture and nerve block combination treatment group(EW group, n=20). The E group received acupuncture treatment on LI15, $TE_{14}$, $GB_{21}$ and Master Dong's acupuncture points, Shin-gwan and Gyun-joong, twice a week for 4 weeks. The W group received suprascapular nerve block, subacromial injection and trigger point injection, twice a week for 4 weeks. The EW group received the same treatment as the W group and after 5minutes of rest, successively received the treatment identical to that of E group. All three groups were instructed to practice groups were instructed to practice self exercise during their daily lives. Evaluations were made before treatment and after 1, 2, 3 and 4week treatment. Constant Shoulder Assessment(CSA), Shoulder Pain and Disability Index(SPADI), Range of Motion(ROM), the patient's treatment satisfaction measured by Visual Analogue Scale(VAS) and Digital Infrared Thermographic Imaging(DITI) were used as assessment tools. The obtained data were analyzed and compared. Results : The E group showed significant improvement(p<0.05) on CSA, SPADI, VAS and DITI. As for ROM, Adduction and Extension improved significantly(p<0.05). The W group showed significant improvement(p<0.05) on CSA, SPADI, VAS and DITI. As for ROM, Abduction and Extension improved significantly. The EW group showed significant improvement(p<0.05) on CSA, SPADI and VAS. As for ROM, Adduction, Abduction, Extension and Flexion improved significantly. The improvement of CSA, VAS and Abduction ROM in the EW group was significantly(p<0.05) superior compared to the groups treated with single type of treatment. Conclusion : It is suggested that acupuncture and nerve block combination treatment for adhesive capsulitis patients is more effective than the two single treatments. Through further studies, the acupuncture and nerve block combination treatment model may be developed into East-West Collaboration Model in treating adhesive capsulitis.

  • PDF

Effect of exposure time and image resolution on fractal dimension (노출 시간과 영상 해상도가 프랙탈 차원값에 미치는 영향)

  • An Byung-Mo;Heo Min-Suk;Lee Seung-Pyo;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.75-79
    • /
    • 2002
  • Purpose : To evaluate the effect of exposure time and image resolution on fractal dimension calculations for determining the optimal range of these two variances. Materials and Methods : Thirty-one radiographs of the mandibular angle area of sixteen human dry mandibles were taken at different exposure times (0.01, 0.08, 0.16, 0.25, 0.40, 0.64, and 0.80 s). Each radiograph was digitized at 1200 dpi, 8 bit, 256 gray level using a film scanner. We selected an Region of Interest (ROI) that corresponded to the same region as in each radiograph, but the resolution of ROI was degraded to 1000, 800, 600, 500, 400, 300, 200, and 100 dpi. The fractal dimension was calculated by using the tile-counting method for each image, and the calculated values were then compared statistically. Results: As the exposure time and the image resolution increased, the mean value of the fractal dimension decreased, except the case where exposure time was set at 0.01 seconds (α = 0.05). The exposure time and image resolution affected the fractal dimension by interaction (p<0.001). When the exposure time was set to either 0.64 seconds or 0.80 seconds, the resulting fractal dimensions were lower, irrespective of image resolution, than at shorter exposure times (α = 0.05). The optimal range for exposure time and resolution was determined to be 0.08- 0.40 seconds and from 400-1000 dpi, respectively. Conclusion : Adequate exposure time and image resolution is essential for acquiring the fractal dimension using tile-counting method for evaluation of the mandible.

  • PDF

Measurement of ROI Temperature in Herniation of Intervertebral Disc Patients Using DITI (디지털 적외선 체열진단기를 이용한 추간판탈출증 환자의 ROI 온도측정)

  • Park, Jeong Kyu;Park, Jong Sam;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.273-278
    • /
    • 2017
  • Among 45 patients of herniation of intervertebral disc with $L_4$ to $L_5$ herniation, who underwent infrared thermography, the number of female was larger than male and the age of 50s was highest. From the results measured from the distribution table, we have confirmed that there was no significant difference depending on sex and age (p> 0.05). The region of the highest ROI temperature for patients with $L_4-L_5$ intervertebral disc prolapse was the back of the posterior right tibia, and followed by the back of the left shin bone-below the front right knee-below the front left knee. There was a significant difference depending on the measured site. The average ROI temperature for patients was $30.30{\pm}0.50$ whereas that for normal persons was $31.20{\pm}0.58$, yielding the temperature difference of $0.66{\pm}0.59$ between the two groups. The ROI of patients was lower than $31.20{\pm}0.58$ (p <0.05) because the significance of the sample, which has been obtained from the results of a sample t-test, was less than 0.05 (p <0.05). From further researches, it may necessary to develope the methodology for correcting data regarding thermal environment and, in addition, to develope a new thermal index based on it. Therefore, we can confirm that pre-treatment for infrared thermography is very important in order to minimize the procedure for correcting data. It is required that radiologists who inspect disc herniations should carefully observe and consider the patients during their measurements.

Augmented Reality Board Game System and PGA (실감형 보드게임 시스템과 PGA)

  • Han, Eun-Jung;Kim, Ki-Rack;Lee, Jang-Hyung;Yoo, Chang-Hyuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.1
    • /
    • pp.163-173
    • /
    • 2011
  • In this paper, we propose a new paradigm of augmented reality board game environment and a portable game assistant(PGA) which can help gamers with strategy information. Previous AR board games consist of a private and public space. The public space provides rules of the game and shows the scene of game. And the gamers control game pieces in the public space. The previous games use the RFIDs for recognizing positions of the pieces, and the VR/AR environment for providing the scene of the game. However the RFIDs are expansive, and the VR/AR environment is inconvenient because it uses additional devices: the DataGlove, the digital pen, and the HMD. The proposed system recognizes positions of real pieces using the computer vision technique, and uses a monitor to provide dynamic effects. In the private space, previous systems provide entire screen of game and position of specific pieces, but cannot be controled the pieces by gamers. Therefore, in this system, we provide PGA that helps the user to plan of the strategy individually using universally mobile. The PGA helps to plan the strategy in the individual area, and to play easily in the side of the user's convenience.

Extraction of the Tree Regions in Forest Areas Using LIDAR Data and Ortho-image (라이다 자료와 정사영상을 이용한 산림지역의 수목영역추출)

  • Kim, Eui Myoung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.2
    • /
    • pp.27-34
    • /
    • 2013
  • Due to the increased interest in global warming, interest in forest resources aimed towards reducing greenhouse gases have subsequently increased. Thus far, data related to forest resources have been obtained, through the employment of aerial photographs or satellite images, by means of plotting. However, the use of imaging data is disadvantageous; merely, due to the fact that recorded measurements such as the height of trees, in dense forest areas, lack accuracy. Within such context, the authors of this study have presented a method of data processing in which an individual tree is isolated within forested areas through the use of LIDAR data and ortho-images. Such isolation resulted in the provision of more efficient and accurate data in regards to the height of trees. As for the data processing of LIDAR, the authors have generated a normalized digital surface model to extract tree points via local maxima filtering, and have additionally, with motives to extract forest areas, applied object oriented image classifications to the processing of data using ortho-images. The final tree point was then given a figure derived from the combination of LIDAR and ortho-images results. Based from an experiment conducted in the Yongin area, the authors have analyzed the merits and demerits of methods that either employ LIDAR data or ortho-images and have thereby obtained information of individual trees within forested areas by combining the two data; thus verifying the efficiency of the above presented method.

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

Quantitative Analysis of Effects for Quality Control on Medical Primary Class LCD Display Devices Based on AAPM TG18 Report (AAPM TG18에 의한 진단용 LCD 디스플레이 장치 정도관리 효과의 정량적 분석)

  • Jung Hai-Jo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2006
  • The image display is an Important component of PACS and of medical digital imaging chain. Displayed image qualify is affected by the physical characteristics of display device, appropriate clinical settings and calibrations, and ambient lighting conditions. The performance of display systems is continuously degraded over time due to luminance deterioration and changes of clinical setting parameters. A routine QC is recommended because the performance of display systems is continuously degraded over time. Ten flat panel monochrome LCD display devices were included in the evaluation of the QC effect. The effect of QC on primary class LCD medical display devices for selected QC tests was evaluated by comparing the performances, luminance response, luminance dependencies, display resolution and display chromaticity in this study, of before and after the calibration procedures. The effects of the QC are significant to luminance response and luminance spatial dependencies test and the other side, are slight to the display resolution and display chromaticity test. A routine QC of display device is essential for the consistency of medical image display and presentation. The study of the QC effects of display devices will play an important role in practical QC procedures of display devices.

  • PDF

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.