• Title/Summary/Keyword: Digital imaging

Search Result 1,509, Processing Time 0.03 seconds

Combustion Characteristics of Single Droplet of Diesel with Bio-diesel for Their Mixing Ratios and Sizes (경유와 바이오 디젤 액적의 혼합비율과 크기에 따른 연소특성)

  • Jeong, Man-Seok;Lee, Kyung-Hwan
    • Journal of Energy Engineering
    • /
    • v.18 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • The combustion characteristics of a single droplet of diesel and bio-diesel have been investigated experimentally with varying droplet size, ambient temperature and compound ratio in a high temperature chamber. The fuels used were diesel with bio-diesel contents varied from 0% to 100%. Each experiment has been performed from 970K to 1070K by 50K intervals. Imaging with a high-speed digital camera was adopted to measure the ignition delay and flame life-time, as well as to observe micro-explosion behavior. The increase of droplet size and decrease of furnace temperature cause an increase of the ignition delay time. As the bio-diesel content decreases, the ignition delay increases and the micro-explosion behavior is strengthened. It is also confirmed that the full combustion time decreases as the micro-explosion occurred.

OLOR-MAGNITUDE RELATIONS OF EARLY-TYPE DWARF GALAXIES IN THE VIRGO CLUSTER: AN ULTRAVIOLET PERSPECTIVE

  • Kim, Suk;Rey, Soo-Chang;Lisker, Thorsten;Sohn, Sangmo Tony
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.38.2-38.2
    • /
    • 2010
  • We present ultraviolet (UV) color-magnitude relations (CMRs) of early-type dwarf galaxies in the Virgo cluster, based on Galaxy Evolution Explorer (GALEX) UV and Sloan Digital Sky Survey (SDSS) optical imaging data. We find that dwarf lenticular galaxies (dS0s), including peculiar dwarf elliptical galaxies (dEs) with disk substructures and blue centers, show a surprisingly distinct and tight locus separated from that of ordinary dEs, which is not clearly seen in previous CMRs. The dS0s in UV CMRs follow a steeper sequence than dEs and show bluer UV-optical color at a given magnitude. We also find that the UV CMRs of dEs in the outer cluster region are slightly steeper than that of their counterparts in the inner region, due to the existence of faint, blue dEs in the outer region. We explore the observed CMRs with population models of a luminosity-dependent delayed exponential star formation history. We confirm that the feature of delayed star formation of early-type dwarf galaxies in the Virgo cluster is strongly correlated with their morphology and environment. The observed CMR of dS0s is well matched by models with relatively long delayed star formation. Our results suggest that dS0s are most likely transitional objects at the stage of subsequent transformation of late-type progenitors to ordinary red dEs in the cluster environment, In any case, UV photometry provides a powerful tool to disentangle the diverse subpopulations of early-type dwarf galaxies and uncover their evolutionary histories.

  • PDF

A semi-automated method for integrating textural and material data into as-built BIM using TIS

  • Zabin, Asem;Khalil, Baha;Ali, Tarig;Abdalla, Jamal A.;Elaksher, Ahmed
    • Advances in Computational Design
    • /
    • v.5 no.2
    • /
    • pp.127-146
    • /
    • 2020
  • Building Information Modeling (BIM) is increasingly used throughout the facility's life cycle for various applications, such as design, construction, facility management, and maintenance. For existing buildings, the geometry of as-built BIM is often constructed using dense, three dimensional (3D) point clouds data obtained with laser scanners. Traditionally, as-built BIM systems do not contain the material and textural information of the buildings' elements. This paper presents a semi-automatic method for generation of material and texture rich as-built BIM. The method captures and integrates material and textural information of building elements into as-built BIM using thermal infrared sensing (TIS). The proposed method uses TIS to capture thermal images of the interior walls of an existing building. These images are then processed to extract the interior walls using a segmentation algorithm. The digital numbers in the resulted images are then transformed into radiance values that represent the emitted thermal infrared radiation. Machine learning techniques are then applied to build a correlation between the radiance values and the material type in each image. The radiance values were used to extract textural information from the images. The extracted textural and material information are then robustly integrated into the as-built BIM providing the data needed for the assessment of building conditions in general including energy efficiency, among others.

Customized 3D Printed Bolus for Breast Reconstruction for Modified Radical Mastectomy (MRM)

  • Ha, Jin-Suk;Jung, Jae Hong;Kim, Min-Joo;Jeon, Mi Jin;Jang, Won Suk;Cho, Yoon Jin;Lee, Ik Jae;Kim, Jun Won;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.196-202
    • /
    • 2016
  • We aim to develop the breast bolus by using a 3D printer to minimize the air-gap, and compare it to commercial bolus used for patients undergoing reconstruction in breast cancer. The bolus-shaped region of interests (ROIs) were contoured at the surface of the intensity-modulated radiation therapy (IMRT) thorax phantom with 5 mm thickness, after which the digital imaging and communications in mdicine (DICOM)-RT structure file was acquired. The intensity-modulated radiation therapy (Tomo-IMRT) and direct mode (Tomo-Direct) using the Tomotherapy were established. The 13 point doses were measured by optically stimulated luminescence (OSLD) dosimetry. The measurement data was analyzed to quantitatively evaluate the applicability of 3D bolus. The percentage change of mean measured dose between the commercial bolus and 3D-bolus was 2.3% and 0.7% for the Tomo-direct and Tomo-IMRT, respectively. For air-gap, range of the commercial bolus was from 0.8 cm to 1.5 cm at the periphery of the right breast. In contrast, the 3D-bolus have occurred the air-gap (i.e., 0 cm). The 3D-bolus for radiation therapy reduces the air-gap on irregular body surface that believed to help in accurate and precise radiation therapy due to better property of adhesion.

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

  • Kim, Bum-Joon;Hong, Ki-Sun;Park, Kyung-Jae;Park, Dong-Hyuk;Chung, Yong-Gu;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.541-546
    • /
    • 2012
  • Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 $cm^2$) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was $184.36{\pm}26.07$ minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.

Study on thermographic change of DITI by acupuncture on sakwan point (사관혈(四關穴)자침이 체열변화에 미치는 영향)

  • Cho, Won-young;Park, Kwae-hwan
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.51-60
    • /
    • 2003
  • Objective: Hapkok(L14) and Taechung(Liv3) are acupuncture points located on both sides of each foot and hand of the human body. These two points are called sakwan points. Matching these acupuncture points have a significant reason in pints of not only regulating the circulation of Yin-Yang as a source point of each meridian, but also playing a basic role of twelve meridian by controlling circulation of ki and blood in the whole body. There are already related documents and studies on stimulating sakwan points. Since those papers mostly studied on either hapkook or taechung, we came to have a doubt of stimulation the two point at the same time when an unbalance of Yin-Yang and ki-blood appears. Accordingly, we got to investigate how thermogram of body changes after applying an acupuncture on sakwan points. Our study is as follows ; Method : Our study was performed on 30 normal cases(M:F=17:13) with no past history to observe the effects of the acupuncture. We measured temperature of abdomen and the back of both hands by D.I.T.I(Digital infrared Thermographic Imaging) before and after acupuncture on sakwan points. Results and Conclusions: The thermographic change on abdomen was $0.51{\pm}0.71^{\circ}C$. Temperature of abdomen after acupuncture was higher than before acupuncture with high validity(p<0.01). And the thermographic changes on the back of both hands were right hand $0.54{\pm}1.17^{\circ}C$, left hand $0.56{\pm}1.28^{\circ}C$. Temperature on the back of both hands after acupuncture was higher than before acupuncture, but the difference between them had little validity(p<0.01). In addition, we found that it doesn't necessarily follow that the thermographic changes on abdomen and back of both hands after acupuncture on sakwan points happen concurrently.

  • PDF

A Clinical Study on Adolescent Idiopathic Scoliosis using DITI (DITI를 활용한 청소년기 특발성 척추측만증에 대한 임상적 고찰)

  • Yang, Tae Jun;Jeong, Sang Jun;Kwak, Min Kyung;Jang, Yeo Jin;Hyun, Min Kyoung;Yoon, Tae Kyung;Kim, Ha Na;Wei, Tung Shuen
    • Journal of Acupuncture Research
    • /
    • v.33 no.4
    • /
    • pp.7-14
    • /
    • 2016
  • Objectives : This study was performed to investigate the correlation between Cobb's angle and digital infrared thermographic imaging(DITI) on adolescent idiopathic scoliosis. Methods : A total of 56 patients with adolescent idiopathic scoliosis were classified into four groups according to their Cobb's angle. Four groups were made for each increment of $5^{\circ}$: group $5-10^{\circ}$, group $11-15^{\circ}$, group $16-20^{\circ}$, and group $21-25^{\circ}$. Next we checked thermal differences of 6 acupoints(GB21, BL13, BL15, BL20, BL23, BL26) on DITI and analyzed correlation by SPSS ver. 20.0.0 for windows. Results : 1. The average patient age was approximately 13 years old. 2. The majority of patients complained of pain on both sides. 3. Significant correlation was found between group $11-15^{\circ}$ and group $16-20^{\circ}$, group $16-20^{\circ}$ and group $21-25^{\circ}$ on Simsu(BL15) by Duncan test. Conclusion : Using DITI, Simsu(BL15) is expected to be a valid indicator for the diagnosis and treatment of adolescent idiopathic scoliosis.

Three-dimensional evaluation of the correlation between lip canting and craniofacial planes

  • Kim, Jun-Young;Park, Hee-Keun;Shin, Seung-Woo;Park, Jin Hoo;Jung, Hwi-Dong;Jung, Young-Soo
    • The korean journal of orthodontics
    • /
    • v.50 no.4
    • /
    • pp.258-267
    • /
    • 2020
  • Objective: This study aimed to analyze the correlation of horizontal and sagittal planes used in two-dimensional diagnosis with lip canting by using three-dimensional (3D) analysis. Methods: Fifty-two patients (25 men, 27 women; average age: 24 years) undergoing treatment for dentofacial deformity were enrolled. Computed tomography images were acquired, and digital imaging and communication in medicine files were reconstructed into a 3D virtual model wherein horizontal and sagittal craniofacial planes were measured. Subsequently, the correlations of lip canting with these horizontal and sagittal planes were investigated. Results: The mandibular symmetry plane, the occlusal plane, Camper's plane, the mandibular plane, Broadbent's plane, and the nasal axis plane were correlated with the amount of lip canting (Pearson's correlation coefficients: 0.761, 0.648, 0.556, 0.526, 0.438, and 0.406, respectively). Planes associated with the lower part of the face showed the strongest correlations; the strength of the correlations decreased in the midfacial and cranial regions. None of the planes showed statistically significant differences between patients with clinical lip canting (> 3°) and those without prominent lip canting. Conclusions: The findings of this study suggest that lip canting is strongly correlated with the mandibular symmetry plane, which includes menton deviation. This finding may have clinical implications with regard to the treatment of patients requiring correction of lip canting. Further studies are necessary for evaluating changes in lip canting after orthognathic surgery.

COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION (CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구)

  • Jung Gi-Hun;Kim Eun-Kyung;Kim Sang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

Benefits and problems in implementation for integrated medical information system

  • Park Chang-Seo;Kim Kee-Deog;Park Hyok;Jeong Ho-Gul
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.185-190
    • /
    • 2005
  • Purpose: Once the decision has been made to adopt an integrated medical information system (IMIS), there are a number of issues to overcome. Users need to be aware of the impact the change will make on end users and be prepared to address issues that arise before they become problems. The purpose of this study is to investigate the benefits and unexpected problems encountered in the implementation of IMIS and to determine a useful framework for IMIS. Materials and Methods: The Yonsei University Dental Hospital is steadily constructing an IMIS. The vendor's PACS software, Piview STAR, supports transactions between workstations that are approved to integrating the healthcare enterprise (IHE) with security function. It is necessary to develop an excellent framework that is good for the patient, healthcare provider and information system vendors, in an expert, efficient, and cost-effective manner. Results : The problems encountered with IMIS implementation were high initial investments, delay of EMR enforcement, underdevelopment of digital radiographic appliances and software and insufficient educational training for users. Conclusions: The clinical environments of dental IMIS is some different from the medical situation. The best way to overcome these differences is to establish a gold standard of dental IMIS integration, which estimates the cost payback. The IHE and its technical framework are good for the patient, the health care provider and all information systems vendors.

  • PDF