• 제목/요약/키워드: Digital hand

검색결과 918건 처리시간 0.029초

A GaAs Power MESFET Operating at 3.3V Drain Voltage for Digital Hand-Held Phone

  • Lee, Jong-Lam;Kim, Hae-Cheon;Mun, Jae-Kyung;Kwon, Oh-Seung;Lee, Jae-Jin;Hwang, In-Duk;Park, Hyung-Moo
    • ETRI Journal
    • /
    • 제16권4호
    • /
    • pp.1-11
    • /
    • 1995
  • A GaAs power metal semiconductor field effect transistor (MESFET) operating at a voltage as low as 3.3V has been developed with the best performance for digital handheld phone. The device has been fabricated on an epitaxial layer with a low-high doped structure grown by molecular beam epitaxy. The MESFET, fabricated using $0.8{\mu}m$ design rule, showed a maximum drain current density of 330 mA/mm at $V_{gs}$ =0.5V and a gate-to-drain breakdown volt-age of 28 V. The MESFET tested at a 3.3 V drain bias and a 900 MHz operation frequency displayed an output power of 32.5-dBm and a power added efficiency of 68%. The associate power gain at 20 dBm input power and the linear gain were 12.5dB and 16.5dB, respectively. Two tone testing measured at 900.00MHz and 900.03MHz showed that a third-order intercept point is 49.5 dBm. The power MESFET developed in this work is expected to be useful as a power amplifying device for digital hand-held phone because the high linear gain can deliver a high power added efficiency in the linear operation region of output power and the high third-order intercept point can reduce the third-order intermodulation.

  • PDF

인태아 수지굴근건의 발육에 관한 전자현미경적 연구 (Ultrastructural Study on the Development of the Flexor Digital Tendon of the Hand in Human Fetus)

  • 윤재룡;안호범;남광일
    • Applied Microscopy
    • /
    • 제26권2호
    • /
    • pp.157-175
    • /
    • 1996
  • The development of flexor digital tendon of the hand was studied by electron microscopy in human fetuses ranging from 9 mm to 260 mm crown rump length. The primordium of tendons was first identified as discrete collection of mesenchymal cells at 25 mm fetus. Synovial sheath formation had commenced by 40 mm fetus and was complete by 70 mm fetus. Cell junction or adhesion sites at all ages were noted between the tendon cells. When dilatation of the synovial cavity occurred, two types of synovial cells were observed. A-type cells had numerous vesicles and large vacuoles. In contrast, B-type cells were characterized by abundant rough endoplasmic reticulum and well-developed Golgi complex. By $150mm{\sim}260mm$ fetuses, a mojority of the synovial cells were type B. The most remarkable difference between the synovial cells of full-term fetus and adult was the larger amount of collagen fibers in the latter. The vascular buds were first observed between the individual fibril bundles in the interfascicular space at 150 mm fetus. At 25 mm fetus, collagen fibrils were first noted within narrow cytoplasmic recesses which were continued with the extracellular space. Collagen fibrils were filled in almost entire extracellular space at 150 mm fetus. Besides collagen fibrils in the extracellular space small elastic fibers were also identified and followed in their development.

  • PDF

[논문표절]수족냉증에 적용한 마사지와 파라핀의 효과 ([Retracted]The effect of Massage and Paraffin on Cold Hypersensitivity Patient)

  • 노효련
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2017년도 춘계 종합학술대회 논문집
    • /
    • pp.101-102
    • /
    • 2017
  • This study of purpose was to evaluate the changes in hands and feet temperature by applying massage and paraffin bath.. The subject of this study was 30 university healthy students. Subjects were divided into paraffin bath group and massages group. The digital infrared thermographic imaging was used for thermographic analysis. The visual analog scale was used for subjective information about the degree of cold sensitivity and cold stress test was used for analyzing the temperature recovery rate. After the interventions showed that temperature difference of the right hand and temperature difference of the left hand are less in the paraffin group than the massage group. When applied paraffin bath and massage to the cold hypersensitivity patient the massage group showed difference in the visual analog scale and the paraffin group showed difference in the temperature of the right hand, left hand, left foot and in the visual analog scale. Paraffin bath treatment seems to be useful to patients with cold hypersensitivity on hands and feet.

A study on procedures of search and seize in digital data

  • Kim, Woon Go
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권2호
    • /
    • pp.133-139
    • /
    • 2017
  • Today, the activities of individuals and corporations are dependent not only on digital technology but also on the future of society, which is referred to as the fourth industrial revolution. Since the traces that arise from the crimes that occur in the digital society are also inevitably developed into a society that should be found in the digital, the judicial dependence of judging by the digital evidence is inevitably increased in the criminal procedure. On the other hand, considering the fact that many users are using virtual shared computing resources of service providers considering the fact that they are being converted into a cloud computing environment system, searching for evidence in cloud computing resources is not related to crime. The possibility of infringing on the basic rights of the criminal procedure is increased, so that the ability of evidence of digital data which can be used in the criminal procedure is limited. Therefore, considering these two aspects of digital evidence, this point should be fully taken into account in judging the evidence ability in the post-seizure warrant issuance and execution stage as well as the pre-emptive control. There is a view that dictionary control is useless, but it needs to be done with lenient control in order to materialize post-modern control through judging ability of evidence. In other words, more efforts are needed than ever before, including legislation to ensure proper criminal procedures in line with the digital age.

VR 영상이 신체 안정성에 미치는 영향 : 손 안정성을 중심으로 (Effects of Virtual Reality Images on Body Stability : Focused on Hand Stability)

  • 한승조;김선욱;구교찬;이근주;조민수
    • 디지털융복합연구
    • /
    • 제15권8호
    • /
    • pp.391-400
    • /
    • 2017
  • 본 논문의 목적은 영상자극이 신체 안정성에 미치는 영향을 개념 모델(Conceptual Model)로 제시하고, 시청자에게 제공되는 영상의 종류(2D, VR)에 따라 신체 안정성(손 안정성)에 미치는 영항을 실험을 통해 알아보는 것이다. 최근에 VR과 같은 입체 영상이 스마트폰이나 운동기구 등과의 결합이 활발해지고 있고, 영상자극이 제거된 후 일시적으로 신체 균형 및 손 안정성에 영향을 미침에 따라 안전사고나 인적오류의 가능성도 높아지고 있다. 개념모델은 기존 연구결과들을 바탕으로 제시되었고, 실험결과를 기반으로 뇌에서 일어나는 인간정보처리과정 및 인지적 자원모델과 결합되어 설명되었다. 20명의 피실험자는 2D, VR 자극에 노출 된 후 영상피로가 Cybersickness 질문지를 통해, 손 안정성은 Hand Steadiness Tester를 이용해 측정되었다. 실험결과 2D보다 VR 영상이 높은 영상피로, 낮은 손 안정성을 유발하였다. 본 연구는 아직 시도되지 않은 영상 종류 및 영상피로 수준에 따른 손 안정성을 개념모델과 실험을 통해 밝혔다는데 의의가 있다.

성별에 따른 우세손과 비우세손의 파악력, 협응력, 기민성 비교 (Comparison of Grip Force, Coordination, and Dexterity Between Dominant and Non-dominant Hand According to Gender)

  • 박찬현;손호희
    • PNF and Movement
    • /
    • 제20권1호
    • /
    • pp.73-81
    • /
    • 2022
  • Purpose: The aim of this study was to present specific criteria for setting goals for hand rehabilitation by comparing the degree of difference in grip force, coordination, and dexterity between the dominant and non-dominant hand according to gender. Methods: We recruited 100 healthy adults in their 20s and 30s. A handheld digital dynamometer was used to evaluate the grip force of each of the dominant and non-dominant hand, a chopsticks manipulation test was used to evaluate coordination, and the Purdue Pegboard test was used to evaluate agility. Results: In all subjects, the grip force, coordination, and dexterity showed statistically significant difference (p <0.01) between the dominant and non-dominant hand. In the comparison according to gender, both male and female dominant and non-dominant hands showed statistically significant differences in grip force, coordination, and dexterity (p <0.01). In the comparison according to grip force, there was a statistically significant difference between the dominant and non-dominant hand, and men showed stronger result values in both hands compared to women (p <0.01). In the comparison according to coordination, there was no statistically significant difference between the dominant and non-dominant hand in men and women (p >0.05). In the comparison according to dexterity, there was a statistically significant difference between the dominant and non-dominant hand, and women were shown to be faster in performance time with both hands, compared to men (p <0.01). Conclusion: Differences according to gender exist in grip force and dexterity but not coordination, and differences between dominant and non-dominant hand exists across all measurements. The results suggest setting a recovery goal according to dominance and gender during rehabilitation of hand function.

Applicability of the digital instrument to improve the reproducibility of motor unit number index

  • Ahn, Suk-Won
    • Annals of Clinical Neurophysiology
    • /
    • 제20권1호
    • /
    • pp.26-30
    • /
    • 2018
  • Background: The motor unit number index (MUNIX) and motor unit size index (MUSIX) refer to the electrophysiological measurement of the motor units using the surface electromyographic interference pattern (SIP) recorded during graded muscle contraction. In order to improve the reliability and reproducibility of MUNIX by the systematization of the graded muscle contractions, we applied a digital hand instrument to the procedure of recording SIP signals. Methods: We tested the applicability of the digital instrument in the MUNIX technique by assessing the mean values and the reproducibility of the MUNIX involving the abductor pollicis brevis (APB) and the abductor digiti minimi (ADM) muscles in 30 healthy adults. Results: The digital dynamometer was successfully applied to the MUNIX measurements of the APB and ADM muscles, and showed high reproducibility across trials. Conclusions: Application of the digital instrument would be useful in improving the reliability and reproducibility of MUNIX.

디지털 문화로 인한 물리적 환경의 변화가능성 예측 연구 (Forecast of Man-Made Physical Environment in Digital Culture)

  • 이기정;이연숙
    • 한국실내디자인학회논문집
    • /
    • 제27호
    • /
    • pp.168-175
    • /
    • 2001
  • This study focuses to enhance the general understanding on the new approach and to provide a clue for a new paradigm in man-made physical and residential environment of the 21st Century. Through case analysis, this study aims to examine the characteristics of digital culture itself and of its physical and residential environment and to ultimately forecast the changeability of physical and residential environment prompted by the new digital wave. Without having precedent study about digital culture related to environmental issues, this study aimed to analyze the effect of digital culture in the field of physical environment and residential environment, and to forecast the changability in those fields. On the other hand, this study also atoned to be applicable in construction of a new paradigm in designing physical & residential environment in the near future, so as to contribute to the development of a new environment which will eventually improve the quality of human life.

  • PDF

Investigations of process factors in the sensitivity of embedded digital switching TSP

  • Han, Sang-Youn;Oh, Keun-Chan;Seong, Dong-Gi;Ham, Yeon-Sik;Lyu, Jae-Jin;Cho, Young-Je
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1531-1534
    • /
    • 2009
  • Effect of process factors on the sensitivity of inner-type digital switching TSP was analyzed. From these results, we have successfully fabricated inner-type digital switching TSP embedded in 3.2-inch WQVGA PLS mode LCD panel. During many factors, TFT sensor structure for reducing the PI thickness and a separation distance of $0.3{\mu}m$ between the conductive column spacer (C/S) and TFT sensor were essential. Glass thickness and main C/S density were also important factors. This technology can be applied to wide angle of view hand-held phones, personal digital assistants (PDAs), and tablet PCs.

  • PDF

계측기(計測器)를 이용한 O-Ring Test법(法)의 검증(檢證)에 관(關)한 연구(硏究) (The Study of Verification Bi-Digital O-Ring Test by gauges)

  • 김정렬;김달래
    • 대한한의학회지
    • /
    • 제16권2호
    • /
    • pp.225-247
    • /
    • 1995
  • Using Bi-Digital O-Ring Test which was developed by Ohmura Toshiaki, constiution classification by the vegetables' was Measured by various muscle power measurement meters and the results are as follow: 1. Pinch Gauge (Model:pc5030HPG, Japan) is the gauge to measure finger power between the thumb and the second finger, Grip Strength Dynamometer (Model: T.K.K. 5101, Japan) is to measure the hand power (hand dynamometer), Back Strength Dynamometer (Model: T.K.K. 5102, Japan) is to measure back muscle strength, Vertical jump Meter (Model: T.K.K. 5106, Japan) is to measure the height of jump. The above gauges were and its result found that the radish, potato, carrot and cucumber can influence to muscle strength was not true. 2. When the physical constitution is distinguished by the O-Ring Test method, Taeyangin's rate appeared as average 21% although it was insisted that there will be only 0.03-0.1%. This means that the physical constitution but it appears accidently according to the examinee's emotion about the material such as vegetable etc. as favor or unfavor. 3. It was found that the result of O-Ring Test is the same at any time and at any place was not true. there is no reemergence character. 4. The import of O-Ring Test mehtod to the physical discrimination disregarded that the mental factor influences absolutely to the physical heath in the ideological physi cal constitution medical science. 5. 'O-Ring Test method is a objective judgement method.' is wrong judgement. As you see on the above result, Bi-Digital O-Ring Test set the changeable voluntary muscle as the standard of the judgument, that was first mistake logically, second in spite of leass influence of mental influence by the examiner and examinee than the vegetable discrimination influence, the test disregarded the influence. Third, only grasp of some material on hand can influence to the voluntary muscle was a wrong theory disregarding the physiology. Finally the misunderstaning his subjective view as an objective view in spite of examiner and examinee's strong influence. Therefore such kind of physical descrimination method must be sublated.

  • PDF