• 제목/요약/키워드: Digital chest x-ray

검색결과 53건 처리시간 0.023초

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측 (Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography)

  • 박여진;주영철;이일수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

X-ray 이미지를 활용한 증강현실 기반 심전도 측정시스템 개발 (Using the X-ray Image, Augmented Reality based electrocardiogram measurement system Development)

  • 이광인;장진수;이태노
    • 디지털융복합연구
    • /
    • 제14권9호
    • /
    • pp.331-339
    • /
    • 2016
  • 경제성장과 함께 생활습관 변화로 인한 만성질환이 지속적으로 증가하고 있다. 그 중 심뇌혈관질환은 사망원인의 약 20%를 차지하는 우리나라의 주요 사망원인이다. 심장의 이상을 측정하는 검사는 심전도검사로, 심장의 리듬을 전기적으로 측정하여 평가하는 방법이다. 심전도 검사에서 가장 영향을 미치는 것은 전극의 부착 위치인데, 간호사를 대상으로 연구한 결과에 따르면 모두 정확하게 부착한 것은 2.6%로 나타났다. 따라서 본 연구는 이러한 문제를 해결하기 위해 프로젝션 기반의 증강현실 기술을 사용하여 환자 본인의 Chest X-ray 사진을 흉부에 중첩시켜 투영시킴으로써 정확한 전극 부착위치를 쉽게 알 수 있는 시스템을 개발하였다. 기존의 방법으로 측정한 결과와 개발한 시스템으로 측정한 결과를 비교하였더니 2.6cm의 오차를 보였다. 그에 따른 심전도 결과에서도 V1, V2, V3위치에서 눈에 띄는 파형의 차이가 있었다. 본 시스템으로 정확하게 측정된 심전도는 의료진들의 환자관리 및 임상적 의사결정에 크게 도움이 될 것이다.

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구 (Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector)

  • 김병기;김상건;차선화;최준구;이준;이민우;김순배;김경수
    • 대한디지털의료영상학회논문지
    • /
    • 제9권2호
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

Glass Dosimeter를 이용한 환자피폭선량에 관한 분석 (Analysis of Patient Exposure dose with Glass Dosimeter)

  • 김재인;최원근;장성원;오창섭;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF

인간의 시각특성에 의거한 디지털 흉부 x-선 영상의 처리 기법 (A New Image Processing Method for Digital Chest Radiographs based on Human Visual System)

  • 김종효;박광석;민병구;임정기;한만청;이충웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.42-47
    • /
    • 1990
  • In this paper, a new adaptive image processing method based on human visual system has been presented. The basic idea behind the proposed method is to improve the efficiency of the information transfer channel regionally by manipulating the displayed image in order to compensate the regional inefficiency of the information transfer channel. The proposed method consists of two parts; the first part reallocates pixel values corresponding to high X-ray attenuation to that of more intense X-ray exposure by multiplying the pixel values with the local adaptive multiplcation factor, and the second part adjusts the pixel values of dark area of displayed image such as overexposed lung area to be more bright. The processed image with the proposed method shows significantly increased visibility of mediastinal and subdiaphramatic area, and also the lung area of over exposed case without any artifact.

  • PDF

변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가 (Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy)

  • 이진수;고성진;강세식;김정훈;박형후;김동현;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제13권3호
    • /
    • pp.204-210
    • /
    • 2013
  • 변형근치유방절제술을 시행한 환자는 일반 여성에 비해 수술로 인한 양측 유방의 두께 차이가 나타나게 되고 이에 따른 감약 차가 생기게 된다. 이에 본 연구는 디지털 영상 특성평가의 객관적인 기준이 되는 MTF를 측정하여 변형근치유방절제술을 시행한 환자들의 흉부촬영에서 적합한 Ion chamber 조합의 기준을 제시하고자 하였다. 디텍터에 위치한 chamber에 좌측 1, 우측 2, 가운데 3으로 번호를 지정하고 엣지팬텀을 부착하여 실험 영상을 획득하였다. 획득한 영상의 해상력 특성 평가는 Matlab(R2007a)를 이용하여 50% MTF 공간주파수의 해상력 평가와 흡수선량을 측정하였다. 실험결과에서 1+3과 2+3조합의 평균 노출조건, 공간주파수, 흡수선량은 각각 2.745 mAs, 1.925 lp/mm, 0.668 mGy로 다른 조합과 비교하여 적은 선량으로 높은 해상력 특성과 높은 DQE를 나타내었다. 따라서 변형근치유방절제술을 시행한 환자의 디지털 흉부영상의 촬영에서는 본 연구에서 제시하는 chamber 조합은 피폭선량 감소와 영상 화질의 향상에 대한 보상이 가능하여 향후 임상에서 적용 및 활용 가능한 chamber 기준이 될 것으로 사료된다.

성인에서 발견된 좌측 폐동맥 형성부전증 1례 (A Case of Left Pulmonary Artery Hypoplasia in Adult)

  • 이승현;최광호;이흥범;이용철;이양근
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권1호
    • /
    • pp.116-121
    • /
    • 1999
  • Unilateral hypoplasia of the pulmonary artery is an uncommon anomaly, which commonly develops in combination with congenital cardiovascular defects such as tetralogy of Fallot, patent ductus arteriosus and septal defect of atrium or ventricle, but may also present as an isolated lesion. We have recently experienced a case of the left pulmonary artery hypoplasia in adult by chance of during the general health screen, which diagnosed by chest X-ray, chest spiral CT, lung perfusion and ventilation scan, digital substraction angiogram and bronchoscopy, then presented hereby with the review of relevant literature.

  • PDF